Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SYLVANIA QTP T8 PSN. We hope that this SYLVANIA QTP T8 PSN user guide will be useful to you.
Lastmanuals help download the user guide SYLVANIA QTP T8 PSN.
Manual abstract: user guide SYLVANIA QTP T8 PSNDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] www. sylvania. com
QUICKTRONIC® PROStart® PSN T8 Universal Voltage
Normal Ballast Factor Professional Series
Lamp / Ballast Guide
Primary Systems 32W T8 1-lamp QTP1x32T8/UNV PSN-TC 2-lamp QTP2x32T8/UNV PSN-TC 3-lamp QTP3x32T8/UNV PSN-SC 4-lamp QTP4x32T8/UNV PSN-SC Also operates: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FO30/SS, FBO30/SS (30W), FBO29/SS, FO28/SS (28W) & FO25/SS (25W) SYLVANIA QUICKTRONIC PROStart programmed rapid start electronic ballasts operate linear U-bend SUPERSAVER® equivalent T8 lamps in applications where extended lamp life is required. [. . . ] This advanced starting process drastically reduces the amount of cathode sputtering, resulting in improved lamp life in all applications including short start cycles.
Lamp & Ballast Type 2-FO32/700 QTP 2x32 ISN 2-FO32/800/XP QTP 2x32 ISN 2-FO32/800/XP QTP 2x32 PSN 2-FO28/SS QTP 2x32 PSN
Input Power (W) 59 59 59 52
Initial Lumens 4930 5280 5280 4800
Initial LPW 84 89 89 92
Mean System Lumens 4435 4965 4965 4510
Relative Mean Light Output Baseline 112% 112% 102%
% Energy Savings Baseline 0% 0% 12%
% Lamp Life Baseline 100% 150% 150%
OCTRON® T8 Lamp Life Comparison
45000 40000 35000 Lamp Life (Hours) 30000 25000 20000 15000 10000 5000 0 15 min 30 min 1 hr 3 hr Start Cycle 12 hr Cont.
PROStart w/ XP, SS & XPS lamps Instant Start w/ XP, SS & XPS lamps Instant Start w/ 700 Series T8 lamps
Application Information
SYLVANIA QUICKTRONIC PROStart T8 is ideally suited for:
· Any applications where extended lamp life is required to reduce maintenance costs · Energy retrofits · Occupancy sensors · Building control systems
QUICK 60+® warranty coverage is included when you use SYLVANIA lamps and ballasts together as a system. See the QUICK 60+ warranty bulletin for complete details. The QUICKTRONIC PROStart ballasts are ideally suited for applications requiring extended lamp life. In short cycle applications, our PROStart ballasts will deliver three times the number of start cycles compared to electronic Instant Start ballasts.
36
SPECIFICATION DATA Catalog # Project Comments Date Prepared by Type
Normal Ballast Factor
T8 PROStart
Input Wattage (W) 31/30 31/30 29/28 27/26 24/23 59/56 59/56 55/53 52/49 46/44 88/85 88/85 83/80 77/75 69/68 118/113 118/113 111/106 104/99 92/90 System Efficacy (lm/W) 79/82 85/88 87/90 89/92 91/95 84/88 89/94 91/95 92/98 95/99 84/87 90/93 91/94 93/96 95/96 83/87 90/94 90/95 92/97 95/97
®
PSN UNV
Professional Series
Performance Guide
Data based upon SYLVANIA OCTRON® lamps shown. QUICKTRONIC® QTP PROStart ballasts are also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications. QTP PROStart ballasts will also operate F17 & F25, SUPERSAVER® & U-Bend equivalent T8 lamps. Complete performance data is available in the QUICKSYSTEMS section of the SYLVANIA Ballast Technology & Specification Guide.
PROStart® Programmed Rapid Start Systems Universal Voltage (120-277V)
Item Number 51399
51400 51401
OSRAM SYLVANIA Description QTP 1x32T8/UNV PSN-TC
Banded Pack 10-Pack Pallet Pack
Input Current (AMPS) 0. 26/0. 11 0. 26/0. 11 0. 24/0. 10 0. 23/0. 09 0. 20/0. 09 0. 50/0. 21 0. 50/0. 21 0. 47/0. 20 0. 45/0. 19 0. 39/0. 17 0. 74/0. 31 0. 74/0. 31 0. 70/0. 29 0. 65/0. 27 0. 58/0. 25 0. 99/0. 41 0. 99/0. 41 0. 93/0. 39 0. 88/0. 36 0. 77/0. 32
Lamp Type FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS
Rated Lumens (lm) 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475
No. of Lamps 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4
Ballast Factor (BF) 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88 0. 88
System Lumens 2465 2640 2510 2400 2175 4930 5280 5015 4800 4355 7390 7920 7525 7195 6535 9855 10, 560 10, 030 9590 8710
Mean Lumens 2220 2480 2360 2255 2045 4435 4965 4715 4510 4095 6655 7445 7075 6760 6140 8870 9925 9430 9015 8190
BEF1 2. 93 2. 93 3. 14 3. 38 3. 83 1. 57 1. 57 1. 66 1. 80 2. 00 1. 04 1. 04 1. 10 1. 17 1. 29 0. 78 0. 78 0. 83 0. 89 0. 98
QTP 2x32T8/UNV PSN-TC 51402
51405 51406 Banded Pack 10-Pack Pallet Pack
Specifications Data based on F32T8
Starting Method: Programmed Rapid-Start Ballast Factor: 0. 88 Circuit Type: Series Lamp Frequency: >40 kHz Lamp CCF: Less than 1. 6 Starting Temp:2 0°F (-18°C) for OCTRON T8 lamps; 60°F (16°C) for SUPERSAVER® T8 lamps Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V rated line (108-305V) UL Listed Class P, Type 1, Outdoor CSA Certified 70°C Max Case Temp. [. . . ] For additional details, refer to our QUICK 60+ warranty bulletin.
Height
Width
Item Number QUICKTRONIC PROFESSIONAL Number of Lamps (1, 2, 3, 4) Primary Lamp Type (F32T8)
Specifications subject to change without notice.
51402 QTP 2 x 32T8 / UNV PSN TC
Enclosure Type (TC or SC) Starting Type/Ballast Factor PROStart/Normal BF Line Voltage (120-277V)
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com 37 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SYLVANIA QTP T8 PSN
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SYLVANIA QTP T8 PSN will begin.