User manual SYLVANIA T5HO PSN HT DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual SYLVANIA T5HO PSN HT. We hope that this SYLVANIA T5HO PSN HT user guide will be useful to you.

Lastmanuals help download the user guide SYLVANIA T5HO PSN HT.


Mode d'emploi SYLVANIA T5HO PSN HT
Download
Manual abstract: user guide SYLVANIA T5HO PSN HTDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. sylvania. com QUICKTRONIC® PROStart® T5HO Universal High Ambient Temp. Professional Series Lamp / Ballast Guide 54W T5 - PENTRON® HO 1 or 2 lamp QTP2x54T5HO/UNV PSN HT QTP4x54T5HO/UNV PSN HT W 3 or 4 lamp QTP4x54T5HO/UNV PSN HT W Also operates: FT50DL, FT55DL, FPC55, L58 Four lamp switchable model can be wired for four, three, two or one lamp operation. SYLVANIA QUICKTRONIC HIGH AMBIENT (HT) PHO operates PENTRON HO, PENTRON HO Circline, and DULUX® L T5 lamps with full lumen output and optimal system performance. [. . . ] Magnetic Ballast (4-lamp) FO32T8/XP - QT4x32IS (4-lamp) FP54T5HO - QTP2x54T5HO/UNV PSN HT (2-lamp) FP54T5HO - QTP4x54T5HO/UNV PSN HTW (4-lamp) · · · · Input Power (W) 172 144 114 121 241 Initial System Lumens 11590 9500 10800 10000 20000 System Efficacy LPW 67 66 95 83 83 Application Information SYLVANIA QUICKTRONIC PHO HT is ideally suited for: · Industrial high-bay · Commercial · Retail · Hospitality · Institutional · New construction · Direct lighting · Indirect lighting · Surface mount · Cove lighting 64 QUICKSENSE ballast technology helps to protect against overheated bases and sockets, as well as cracking of the lamp glass wall, and uses dynamic end-oflamp-life sensing to avoid false shutdowns caused by some static sensing methods. QUICKSENSE ballast technology will auto reset when spent lamps are replaced with new ones. The four lamp unit can be wired for four, three, two or one lamp operation. The two lamp unit can be wired for one lamp operation, allowing for an additional 50% reduction in inventory model numbers. PENTRON T5 lamps are designed to provide peak performance at 35°C fixture ambient, allowing for smaller and more innovative fixtures. SPECIFICATION DATA Catalog # Project Comments Date Prepared by Type High Ambient Temp. T5HO PROStart Input1 Power (Watts) System Efficacy (lm/W) ® Professional Series Performance Guide Rated1 Ballast1 Lumens No. of Factor (lm) Lamps (BF) System1 Lumens Mean1 Lumens High Ambient Universal Voltage (120-277V) Item Number Input Current (AMPS) Lamp1 Type Description BEF2 QTP 2x54 T5HO Fixed Output BF 1. 0 49136 (49135)* QTP 2x54T5HO/UNV PSN HT 1. 00/0. 43 FP54T5HO 5000 2 1 1. 00 1. 00 10000 5000 9300 4650 121/118 61 83/85 82 0. 85 1. 64 Data based upon SYLVANIA PENTRON® HO lamps shown. QUICKTRONIC® PHO HT ballasts are also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications. QTP 4x54 T5HO Switchable Model 49161 QTP 4x54T5HO/UNV PSN HTW (49160)** 2. 00/0. 85 FP54T5HO 5000 4 3 2 1 1. 00 1. 00 1. 00 1. 00 20000 15000 10000 5000 18, 600 13, 950 9300 4650 241/236 182/178 121/118 61 83/85 83/85 83/85 82 0. 42 0. 56 0. 85 1. 64 Specifications3 Starting Method: Programmed Rapid Start Ballast Factor: 1. 00 Circuit Type: Series Lamp Frequency: >40 kHz Lamp CCF: Less than 1. 6 Starting Temp: -20°F (-29°C) min. 4 Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V rated line (108-305V) UL Listed Class P, Type 1, Outdoor, UL Type CC Rated CSA Certified High Ambient Applications: 90°C Max. warranty) Standard Ambient Applications: 70°C Max. warranty) FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62. 41 Cat. A Transient Protection Dynamic End-of-Lamp-Life Sensing Remote Mounting (Max. wire length from ballast case to lampholder): up to 18 feet4 3 Data based on PENTRON HO lamp types for primary ballast application. [. . . ] For additional details, refer to our QUICK 60+ warranty bulletin. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com 65 Item Number QUICKTRONIC PROFESSIONAL Number of Lamps 49161 QTP 4 x 54 T5HO / UNV PSN HTW High Ambient Temperature (Case) Starting/Ballast Factor Line Voltage (120-277V) Primary Lamp Wattage Specifications subject to change without notice. SPECIFICATION DATA Catalog # Project Comments Date Prepared by Type 2 LAMP T5HO UNV HT Fixed Output Ballast Professional Series Lamp / Ballast Guide <10% THD Electronic 2 Lamp T5HO High Ambient Fluorescent Systems High ambient model (90°C case temp. ) 49136 QTP 2x54T5HO/UNV PSN HT Wiring diagram for 2-Lamp model Black White BALLAST T5HO PSN HT LAMP LAMP Red Yellow Blue 2 LAMP Installation Notes · Install in accordance with National & Local Electric Code · Ground ballast case · Switching: Simultaneously disconnect all ungrounded line conductors 2-Lamp model can be wired for one lamp operation. Black White BALLAST Red LAMP Blue 1 LAMP Item Number QUICKTRONIC PROFESSIONAL Number of Lamps (1, 2) 49136 QTP 2 x 54 T5HO / UNV PSN HT High Ambient Temperature (Case) Starting/Ballast Factor Line Voltage (120-277V) Primary Lamp Wattage OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com 66 Specifications subject to change without notice. SPECIFICATION DATA Catalog # Project Comments Date Prepared by Type 4 LAMP T5HO UNV HT Switchable Ballast Professional Series Switching Schematics <10% THD Electronic 4 Lamp T5HO High Ambient Fluorescent Systems 4-Lamp Switching Wiring Diagram (4L to 2L) S1 (Output A) Closed (ON) Closed (ON) Open (OFF) Open (OFF) S2 (Output B) Closed (ON) Open (OFF) Closed (ON) Open (OFF) Lamp Control All 4 Lamps ON (Output A&B ON) 2 Lamps ON (Output A ON) 2 Lamps ON (Output B ON) All Lamps OFF Output A S1 Output B S2 (Red Switching Line) High ambient switchable model (90°C case temp. ) 49161 QTP 4x54T5HO/UNV PSN HT W T5HO PSN HT Installation Notes 3-Lamp Switching Wiring Diagram (3L to 2L, 3L to 1L) S1 (Output A) Closed (ON) Closed (ON) Open (OFF) Open (OFF) S2 (Output B) Closed (ON) Open (OFF) Closed (ON) Open (OFF) Lamp Control All 3 Lamps ON (Output A&B ON) 2 Lamps ON (Output A ON) 1 Lamp ON (Output B ON) All Lamps OFF · Install in accordance with National & Local Electric Code · Ground ballast case · Switching: Simultaneously disconnect all ungrounded line conductors · The AC line inputs must be connected to the same phase of the line voltage · DO NOT CONNECT two separate phases of line voltage to the input of the ballast Input wiring for non-switching operation (Install jumper between black & red switching line terminals) Output A S1 Output B S2 (Red Switching Line) 2-Lamp Switching Wiring Diagram (2L to 1L) S1 (Output A) Closed (ON) Closed (ON) Open (OFF) Open (OFF) S2 (Output B) Closed (ON) Open (OFF) Closed (ON) Open (OFF) Lamp Control 2 Lamps ON (Output A&B ON) 1 Lamp ON (Output A ON) 1 Lamp ON (Output B ON) All Lamps OFF Input wiring for occupancy sensors (Install occupancy sensor/switch between black & red line terminals) Output A S1 Output B S2 (Red Switching Line) Item Number QUICKTRONIC PROFESSIONAL Number of Lamps 49161 QTP 4 x 54 T5HO / UNV PSN HTW High Ambient Temperature (Case) Starting/Ballast Factor Line Voltage (120-277V) Primary Lamp Wattage OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www. sylvania. com 67 Specifications subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SYLVANIA T5HO PSN HT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual SYLVANIA T5HO PSN HT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag