User manual TANDBERG MSERIES USER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TANDBERG MSERIES USER. We hope that this TANDBERG MSERIES USER user guide will be useful to you.

Lastmanuals help download the user guide TANDBERG MSERIES USER.


Mode d'emploi TANDBERG MSERIES USER
Download
Manual abstract: user guide TANDBERG MSERIES USER

Detailed instructions for use are in the User's Guide.

[. . . ] Tandberg Data M-Series User's Guide T6423045-03 A01 Tandberg Data M-Series User's Guide, T6423045-03 A01, February 2004, Made in USA. Tandberg Data provides this publication "as is" without warranty of any kind, either express or implied, including but not limited to the implied warranties of merchantability or fitness for a particular purpose. Tandberg Data may revise this publication from time to time without notice. COPYRIGHT STATEMENT © Copyright 2004 by Quantum Corporation. [. . . ] To set the emulation: 1 Access the Configuration screen (see Accessing the Configuration Screen on page 49). 2 Press the Up or Down buttons until Emulation is highlighted. 4 Use the Up or Down buttons to select the desired Emulation setting. The available settings are M2500, 1500, and M4 Data. Note: The default setting for the M1500 is M4 Data; the default setting for the M2500 is M2500. 3 5 Press Select. To return to the Configuration screen without changing the option setting, press Cancel. 6 Press Main to return to the main screen. Note: This setting takes effect when you reboot the library. Changing the Storage Slot Count Setting The Storage Slot Count option controls how many storage elements are reported to the SCSI host. Note: When changing this option setting in a multiple library stack, you must use the GUI on the SCSI master (the library module connected to the SCSI host) in order for the changes to take effect. 3 54 Tandberg Data M-Series User's Guide Chapter 3 Changing the Library Configuration Changing the Sync Negotiation Setting To change the Storage Slot Count setting: 1 Access the Configuration screen (see Accessing the Configuration Screen on page 49). 2 Press the Up or Down buttons until Storage Slot Count is highlighted. 4 Use the Up or Down buttons to select the desired Storage Slot Count setting. The available settings are: · · Default (all storage elements detected by the library are reported to the SCSI host) Any value from 1 through the number of storage elements in the library (this number varies depending on the library, the tape drive type, and the setting of the Import/Export and Auto Clean options). 5 Press Select. 6 To return to the Configuration screen without changing the option setting, press Cancel. 7 Press Main to return to the main screen. Note: This setting takes effect when you reboot the library. Changing the Sync Negotiation Setting 3 The Sync Negotiation option controls whether the library robotics negotiates synchronous data transfer mode. Normally, this negotiation is performed by the host. Note: This option does not enable or disable synchronous data transfers; it only controls the ability of the library to negotiate for such transfers. Tandberg Data M-Series User's Guide 55 Chapter 3 Changing the Library Configuration Changing the Wide Negotiation Setting To enable or disable Sync Negotiation: 1 Access the Configuration screen (see Accessing the Configuration Screen on page 49). 2 Press the Up or Down buttons until Sync Negotiation is highlighted. 4 Use the Up or Down buttons to select the desired Sync Negotiation setting. The available settings are Enabled (default) and Disabled. To return to the Configuration screen without changing the option setting, press Cancel. 6 Press Main to return to the main screen. Changing the Wide Negotiation Setting The Wide Negotiation option controls whether the library robotics negotiates wide data transfer mode. [. . . ] Any changes or modifications made to this equipment may void the user's authority to operate this equipment. Operation of this equipment in a residential area may cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: 1 This device may not cause harmful interference, and 2 This device must accept any interference received, including interference that may cause undesired operation. Tandberg Data M-Series User's Guide 165 Appendix D Regulatory Statements Taiwan Statement !" #$%&'()*+ , -. 4 Industry Canada (Digital Apparatus) Reference: Interference-Causing Equipment Standard, ICES-003, Issue 2 This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. 4 CISPR-22 Warning! 4 This is a Class A product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TANDBERG MSERIES USER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TANDBERG MSERIES USER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag