User manual TANDBERG STORAGELOADER INSTALLATION AND USER MANUAL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TANDBERG STORAGELOADER. We hope that this TANDBERG STORAGELOADER user guide will be useful to you.
Lastmanuals help download the user guide TANDBERG STORAGELOADER.
Manual abstract: user guide TANDBERG STORAGELOADERINSTALLATION AND USER MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] StorageLoaderTM
INSTALLATION AND USER MANUAL
TANDBERG DATA ASA P. O. Box 134 Kjelsås N-0411 OSLO, NORWAY Phone + 47 22 18 90 90 Telefax + 47 22 18 95 50 www. tandberg. com © Tandberg Data ASA
Part No. May
433061-04 2006
Related publications available from Tandberg Data ASA: Part No. 432980 433060 Title Tandberg Data StorageLoader SCSI Interface Functional Specifications. [. . . ] StorageLoader FW id and revision Current Inquiry Vendor Id Current HW/FW Product Id SCSI Id 0 to SCSI Id 15 Disabled, Enabled View status for each loader slot VS160: AT1280- 1R VS160 LTO : AT1280- 1R VS160 AT3200- 1R LTO2 StorageLoader Enabled, Disabled
Disabled Enabled if installed, else Disabled --xx. yy "TANDBERG" AT1280- 1R VS160 or AT3200- 1R LTO2 SCSI ID = 4 Enabled Not applicable VS160 : AT1280- 1R VS160
Audible Alarm
Disabled
* Can only be enabled if a barcode scanner is installed.
4. 5. 2 Drive Info
The different drive t ypes used in t he St orageLoader m ay not provide all t he inform at ion list ed below. I f an unavailable ent ry is selected, the string "Data Unavailable is displayed.
Item name Drive Product ID Drive Vendor ID Drive FW Revision Drive Serial No. Drive SCSI Id Legal values Drive Inquiry Product Id Drive Inquiry Vendor Id Drive Firmware Revision Drive Serial Number SCSI Id 0 to SCSI Id 15 Default value Drive dependent Drive dependent Drive dependent Drive dependent SCSI ID = 5
38
StorageLoader Installation and User Manual
Tandberg Data
Operation and Configuration
4. 5. 3 Remote Management Info
The Rem ot e Managem ent ( RMM) set up is shown in t he choices list ed below. This m enu t hree is t he place t o find t he current ly allocat ed dynam ic I P address, default gat eway and net work m ask when running in DHCP m ode. The MAC address of t he Loader is also shown here.
Item name IP address mode Static IP address Static netmask Static default gateway Dynamic IP address Dynamic netmask Legal values Static mode, DHCP mode 0. 0. 0. 0 to 255. 255. 255. 255 0. 0. 0. 0 to 255. 255. 255. 255 0. 0. 0. 0 to 255. 255. 255. 255 0. 0. 0. 0 to 255. 255. 255. 255 0. 0. 0. 0 to 255. 255. 255. 255 Default value DHCP mode 0. 0. 0. 0 0. 0. 0. 0 0. 0. 0. 0 Not applicable Not applicable Not applicable Value is fixed
Dynamic 0. 0. 0. 0 to default gateway 255. 255. 255. 255 MAC- address Value is fixed
4. 5. 4 Statistics
Item name Fetch Statistics Stow Statistics Power On Time Time since clean Description When select ed, t he operat or can scroll t hrough t he fet ch count and fet ch ret ries for t he drive and all magazine slots. When select ed, t he operat or can scroll t hrough the stow count and stow retries for the drive and all magazine slots. Displays Power On Hours for the loader I f available from t he drive, t his ent ry displays num ber of hours since t he drive was last cleaned.
4. 6 Utilities Menu
Option Maintenance Description Displays a set of maintenance functions
StorageLoader Installation and User Manual
39
Tandberg Data
Operation and Configuration
Diagnostics Access control
Displays a list of exercise test programs Set Password
4. 6. 1 The Maintenance Menus
Item name Description
Prepare to Ship
When selected the robotics will be positioned for installation of the locking screw. It will eject the Right magazine to facilitate the installation. It will also eject the left magazine if it contains one or more cartridges. The Loader cannot be safely shipped with cartridges in the magazines This option must be executed before the loader is prepared for transport by inserting the Locking Pin. (See chapters 3. 1, Performing the Installation and 6. 4, Reinstalling the Transport Lock. )
Clean Drive
Performs a drive clean provided a slot is reserved for a cleaning tape and a cleaning tape is present Sets the loader settings to their factory default values. This is useful when the password is lost. Performs a hard reset of the loader.
Restore default Clear Web Password Reboot
4. 6. 2 The Diagnostics Menu
Item name System test Description Starts a test where cartridges are moved randomly between magazine slots and between the drive and the magazines. Starts a test where cartridges are moved randomly between magazine slots. (Only when supported by the installed tape drive. ) Runs a test of the loader hardware, including the Loader internal cabling.
Move medium test Drive test Hardware test
40
StorageLoader Installation and User Manual
Tandberg Data
Operation and Configuration
4. 6. 3 Set Password
Item name Set Password Description Allows the operator to set a four- digit password protection for the menu system. The default password is <0000>, meaning the password is disabled.
WARNING: If you set a password, make sure you do not forget it. If you do, it ca n on ly be cle a r e d w it h a ssist a n ce fr om Ta n dbe r g D a t a t e ch n ica l support or by a qualified service technician.
4. 7 Cartridge Handling
4. 7. 1 Cartridge Slot Numbers
The cart ridge slot s have been given num bers as follow: ( see also Figure 2. 3 Internal components of the StorageLoader) Left m agazine: Slot 1, Slot 2, Slot 3 and Slot 4 ( lowest num ber closest to the front) Right m agazine: Slot 5, Slot 6, Slot 7 and Slot 8 ( lowest num ber closest to the front)
4. 7. 2 Moving Cartridges to and from the Drive
The norm al operat ions of t he unit are cont rolled by t he host soft ware applicat ion. When you m ust load or unload a specific cart ridge using t he cont rol but t ons on t he front panel, do t he following: To load a cartridge to the drive: 1. From t he default display press t he m enu but t on and select Load t o Drive from t he m ain m enu. A screen pict ure like figure 4. 11 will be displayed. I f a Barcode reader is im plem ent ed, t he selected cartridge's barcode is displayed in the bottom line.
Ok Load to drive From Slot: 135 Figure 4. 11 Load to Drive Cancel
2. Select t he slot num ber of your choice. [. . . ] Reboot the loader and retry the operation. Verify that the cartridge is not damaged. Retry the operation with a new magazine Defect robotics, defect magazine, defect cartridge (This error code is reserved for future use) Cartridge blocked, faulty robotics
01ZZ
Diagnostic number ZZ failed. Initialization of the robotics failed.
0200
1001
Failed moving the robotics. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TANDBERG STORAGELOADER Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TANDBERG STORAGELOADER will begin.