User manual TEKTONE NC205 NURSE CALL SYSTEM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TEKTONE NC205 NURSE CALL SYSTEM. We hope that this TEKTONE NC205 NURSE CALL SYSTEM user guide will be useful to you.

Lastmanuals help download the user guide TEKTONE NC205 NURSE CALL SYSTEM.


Mode d'emploi TEKTONE NC205 NURSE CALL SYSTEM
Download
Manual abstract: user guide TEKTONE NC205 NURSE CALL SYSTEM

Detailed instructions for use are in the User's Guide.

[. . . ] 26 - 09/2002 Tek-DIGICARE® NC205 Nurse Call System UL® Listed 1069 INSTALLATION INSTRUCTIONS AND SERVICE MANUAL Website: www. tektone. net Email: tektone@tektone. net For Technical Assistance: 1-800-332-6608 Technical Assistance Email: teksupt@tektone. net 277 Industrial Park Road Franklin, NC 28734 (828) 524-9967 (800) 327-8466 Fax (828) 524-9968 4190 Fairview St. , Unit B-8 Burlington, ON L7L 4Y8 Canada (905) 333-0051 Fax (905) 333-0599 APPLICATION: The NC205 Tek-DIGICARE® Nurse Call System is a microcontroller based system consisting of central equipment cabinet(s) along with patient/duty/staff/emergency/code/presence stations, dome/zone lights, and master stations. The NC205 Series is designed for use in individual hospital wards, nursing homes, and congregate living centers. Copyright © TekTone Sound & Signal Mfg. , Inc. All Rights Reserved. Operation, Installation and Service Manual Copyright © 2002 TekTone® Sound & Signal Mfg. , Inc. , All rights reserved. No part of this publication may be copied without the express written permission of TekTone® Sound & Signal Mfg. , Inc. [. . . ] To view the priority status of stations, press the "PRIORITY" button. Stations upgraded to Priority will be indicated by the fast flashing of that station's selector button LED. Stations that have been upgraded to Personal Attention will be displayed with a slow flash rate (excludes IR250-IR253 and IR260A). This display will clear after eight seconds or when the "RESET" button is pressed. To follow a staff member, press the "FOLLOW" button followed by the "STAFF" button. Call tones will be sent to rooms in the preset zones where staff presence is registered, as well as stations that are marked as staff stations. To follow to a specific room, press the "FOLLOW" button, then select the room. Call tones will be sent to the selected room only. To discontinue the follower function, press "RESET". To view a station's zone assignments and status, press the individual station's selector button followed by the"ZONE" button. A display will appear showing the zones assigned to the station in the numerical key column. The alpha key column will display the station's status indicators. NOTE: Station's selector button LED will light momentarily and then extinguish before the zone information is retrieved. (See System Configuration/ Programming Section 5. 2-1. ) A. To enable room monitoring, simply press the desired station selector button(s). Multiple rooms (up to a maximum of 20) may be monitored by simply selecting them one after another (all stations must be on the same selector card and in the same zone). Press the "RESET" button to discontinue the monitor function. To view the master's zone assignments and status, press the "ZONE" button. A display will appear showing the zones assigned to the master in the numerical key column. (The alpha key column will display the master's status indicators. See System Configuration/Programming Section 5. 1-1. ) Press "RESET" to conclude this function. 26 · IL600 NC205 Tek-DIGICARE® Manual Copyright © TekTone Sound & Signal Mfg. , Inc. All Rights Reserved. 4. 2 IR SERIES STATIONS 4. 2-6 IR260A Duty Station To reply to a call, speak in a normal voice when spoken to. [. . . ] NOTE: Fire indication at the nurse master station is supplementary only. The NC205 system is not intended for use as a fire alarm evacuation system. TITLE: APP: IR259 Enhanced Station Wiring D R A W N B Y : MJF/DE REV: D A T E : 09/18/2000 PAGE: NC205 Nurse Call System 5 NL205-O SELECTIVE WIRE TRUNK 66 · IL600 NC205 Tek-DIGICARE® Manual Copyright © TekTone Sound & Signal Mfg. , Inc. All Rights Reserved. NOTE : A 1. 5K ohm resistor (TekTone part # RC028, 1/2W, 5%) must be installed across the POWER and BLUE lamp terminals of the LI387 when an SF341B Code Call station is used as a Stand-Alone station. 1. 5K ohm POWER STATION COMMONS BUSS NOTE : System Ground and Power for stand-alone devices can be run from the STATION COMMONS BUSS or from the FLASHER BUSS. DOME LIGHT LI387 POWER BLUE #18 POWER OR SYSTEM GROUND DOME LIGHT LI382 POWER BLUE DOME LIGHT LI382 POWER WHITE LI387 DOME LIGHT LI381 POWER WHITE FLASHER BUSS WHITE WHITE RED RED FAST FLASH SLOW FLASH #18 #18 #18 VISUAL-ONLY STATION SF100C SF101C 1 2 3 4 5 6 (UNSUPERVISED) SF341B 1 2 3 4 5 6 7 8 CODE CALL STATION EMERGENCY STATION 1 2 3 4 5 6 7 SF330 SF337B SF337C SF340B SMOKE DETECTOR Auxillary Contacts N. O. N. C. Alarm Contact N. O. IMPORTANT NOTE : Stand-Alone stations must be marked for FAULT DEFEAT and PRIVACY at the associated master station. (SF337C only) SF337C only! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTONE NC205 NURSE CALL SYSTEM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTONE NC205 NURSE CALL SYSTEM will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag