User manual TEKTRONIX 2213 OPERATORS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TEKTRONIX 2213. We hope that this TEKTRONIX 2213 user guide will be useful to you.

Lastmanuals help download the user guide TEKTRONIX 2213.


Mode d'emploi TEKTRONIX 2213
Download

You may also download the following manuals related to this product:

   TEKTRONIX 2213 SERVICE (14865 ko)

Manual abstract: user guide TEKTRONIX 2213OPERATORS

Detailed instructions for use are in the User's Guide.

[. . . ] COMMITTED TO EXCELLENCE PLEASE CHECK FOR CHANGE INFORMATION AT THE REAR OF THIS MANUAL. 2213 OSCILLOSCOPE OPERATORS INSTRUCTION Tektronix, Inc. Box 500 Beaverton, Oregon 070-3397-00 Product Group 46 97077 MANUAL Serial Number __________ First Printing JUN 1981 Revised AUG 1982 2213 Operators CONTROLS, CONNECTORS, AND INDICATORS The following descriptions are intended to familiarize the operator with the location, operation, and function of the instrument' controls, connectors, and indicators. s be maintained as changes occur in the intensity level of the trace. POWER, DISPLAY, AND PROBE ADJUST 4 0 1 0 Refer to Figure 3 for location of items 1 through 7. Internal Graticule-Eliminates parallax viewing error between the trace and graticule lines. [. . . ] Perform Step 1 under Displaying a TV Line-rate Signal. 2. Set A SEC/DIV to 2 ms, A TRIGGER MODE to TV FIELD and A & B INT to CH 1 or CH 2 as appropriate for the applied signal. Perform Step 3 and 4 under Displaying a TV Line-rate Signal. To display either Field 1 or Field 2 individually at faster sweep rates (displays of less than one full field), set VERTICAL MODE to BOTH and ALT simultaneously. This synchronizes the Channel 1 display to one field and the Channel 2 display to the other field. To change the field that is displayed, interrupt the triggering by repeatedly setting the AC GND DC switch to GND or disconnecting the signal from the applied signal input until the other field is displayed. To display both fields simultaneously, apply the input signal to both the CH 1 and CH 2 inputs via two probes, two cables, or through a dual-input coupler. To examine either a TV Field-rate or Line-rate signal in more detail, either the X10 Magnifier or HORIZONTAL MODE functions may be employed as described for other signals elsewhere in this manual. TV SIGNAL DISPLAYS Displaying a TV Line-rate Signal 1. Perform the steps and set the controls as outlined under Baseline Trace and Signal Display to obtain a basic display of the desired TV signal. Set A SEC/DIV to 10 I_LS, and A & B INT to CH 1 or CH 2 as appropriate for applied signal. Set A TRIGGER SLOPE for a positive-going signal (lever up) if the applied TV signal sync pulses are positivegoing, or for a negative-going signal (lever down) if the TV sync pulses are negative-going. OPERATOR' ADJUSTMENTS S INTRODUCTION Two adjustments should be performed before making measurements with your oscilloscope: Trace Rotation and Probe Compensation. Before proceeding with the following adjustment instructions, verify that the correct line fuse is installed (refer to the " Preparation for Use" information). Verify that the POWER switch is OFF (button out), then plug the power cord into the ac-power-input source. Push in the POWER switch (ON) and allow a 20-minute warm-up time before starting these adjustments. NOTE Normally, the resulting trace will be parallel to the center horizon tal graticule line, and the Trace Rotation adjustment should not be required. If the resulting trace is not parallel to the center horizontal graticule line, use a small flat-bit screwdriver to adjust the TRACE ROTATION control and align the trace with the center horizontal graticule line. PROBE COMPENSATION Misadjustment of probe compensation is one of the sources of measurement error. Most attenuator probes are equipped with compensation adjustment. To ensure optimum measurement accuracy, always compensate the oscilloscope probe before making measurements. Probe compensation is accomplished as follows: TRACE ROTATION -1. Pre set instrument controls and obta in a baseline er lnstrumen t Familiar izati on") . Use the Channel 1 POSITION control to move the baseline trace to the center horizontal graticule line. REV OCT 1981 15 2213 Operators 1. Preset instrument controls and obtain a baseline trace (refer to " Instrument Familiarization" ). CORRECT FLAT 2. [. . . ] Continuously variable between calibrated settings. Extends the sweep speeds by at least a factor of 2. 5. Variable Control Range Delay Time Range Selector Minimum delay is less than selected values of 0. 5 ps, 10 ps, and 0. 2 ms. Increases delay time by at least a factor of 20. One part, or less, in 5, 000 (0. 02%) of the maximum available delay time. MULTIPLIER Control Jitter X-Y OPERATION (Xl MAGNIFICATION) Deflection Factors Range Same as Vertical Deflection System, with both VOLTS/DIV Variable controls in CAL detent. aPerformance Requirement not checked in Service Manual. @ 29 2213 Operators Table 2 (cont) Characteristics I Performance Requirements Supplemental Information X-Y OPERATION (Xl MAGNIFICATION) (cont) Deflection Factors (cont) Accuracy +2o" to +3o" c c 0°C to +5o" c Bandwidth X-Axis Y-Axis Phase Difference Between Xand Y-Axis Amplifiers D C to at least 2 MHz. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX 2213

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX 2213 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag