User manual TEKTRONIX DSA8200 DATASHEET - DIGITAL SERIAL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TEKTRONIX DSA8200. We hope that this TEKTRONIX DSA8200 user guide will be useful to you.
Lastmanuals help download the user guide TEKTRONIX DSA8200.
Manual abstract: user guide TEKTRONIX DSA8200DATASHEET - DIGITAL SERIAL
Detailed instructions for use are in the User's Guide.
[. . . ] Digital Serial Analyzer Sampling Oscilloscope
DSA8200 Data Sheet
Jitter, Noise, BER, and Serial Data Link Analysis Measures and Separates Deterministic Data-dependent Jitter from Random Jitter Measures Vertical Noise, Separating Deterministic Data-dependent Noise from Random Noise Highly Accurate BER and Eye Contour Estimation, Support for DDPWS FFE/DFE Equalization, Transmitter Equalization Channel Emulation for Channels with >30 dB of Loss Linear Filter for Fixture De-embedding, Linear Filtering TDR (Time Domain Reflectometry) Up to 50 GHz TDR Bandwidth with 15 ps Reflected Rise Time and 12 ps Incident Rise Time Lowest Noise for Accurate Repeatable TDR Measurement Results 600 VRMS at 50 GHz Independent Sampler Deskew ensures Easy Fixture and Probe De-embedding Industry's Only Mainframe to Accommodate up to Four True-differential TDR or Electrical Channel Pairs for Increased System Versatility S-parameters Measurements Up to 50 GHz Differential, Single Ended, Mixed Mode; Insertion, Return Loss, Frequency Domain Crosstalk PCI Express, Serial ATA, Infiniband, Gigabit Ethernet Manufacturing, and Standard Compliance Testing for Gigabit Signal Path and Interconnects Including Eye Mask Tests Intuitive, Easy, and Accurate for Serial Data, Gigabit Digital Design, and Signal Integrity Fast and Accurate Automated Multiport S-parameter Measurements with Command Line Interface Industry's Best Standard Time-base Jitter Performance, 800 fsRMS Industry-leading Time-base Jitter Performance, <200 fsRMS*1 Available with Phase Reference Mode Fast Acquisition Rate and High Throughput True-differential Remote Sampler enabling Placement Near DUT for Superior Signal Fidelity FrameScanTM Acquisition Mode with Eye Diagram Averaging: Isolate Data-dependent Faults Examine Low-power Signals MS Windows XP Operating System Advanced Connectivity to 3rd party Software
Features & Benefits
State-of-the-Art Sampling Oscilloscope for Communication Signal Analysis, TDR / TDT / Serial Data Network Analysis, Acquisition, and Measurements of Repetitive Ultrafast Signals Acquisition of Spread Spectrum Clocking (SSC) Signals Industry's Only Mainframe to Support up to 8 Input Channels for Increased Flexibility and Throughput Four Color-graded, Variable Persistence Waveform Databases Measurement System with Over 100 Automated Measurements Complete Suite of Communications Measurements includes Both Types of OMA, SSC Profile, and Many Others Automated ITU/ANSI/IEEE Mask Testing Masks and Measurements for SONET/SDH, FC, Ethernet, and Other Standards Built-in Mask Updates can be Loaded from Factory-supplied File Mask Margin Testing for Guard Banding Production Testing Acquisition Modules Fully Integrated Multirate Optical Modules Optical Modules up to 80 GHz 80C10B High-accuracy "ER Calibrated" Measurement Available in Some Modules Electrical Modules up to 70+ GHz Bandwidth and 5 ps Measured Rise Time (10-90%) Flexible Rate Clock Recovery Clock Recovery with SSC (Spread Spectrum Clocking) Support Available
Data Sheet
Applications
Design/Verification of Telecom and Datacom Components and Systems Manufacturing/Testing for ITU/ANSI/IEEE/SONET/SDH Compliance High-performance True-differential TDR Measurements Advanced Jitter, Noise, and BER Analysis Impedance Characterization and Network Analysis for Serial Data Applications including S-parameters Channel and Eye Diagram Simulation and Measurement-based SPICE Modeling
*1 Typical, with the Phase Reference module, some conditions apply. Without the module, the jitter is <800 fsRMS (typical).
samplers, offer up to 50 GHz bandwidth and 15 ps reflected rise time and 12 ps incident rise time. The family of low-noise variable-bandwidth electrical modules provides the industry's best noise performance with remote samplers, featuring 450 VRMS noise at 60 GHz, and 300 VRMS at 30 GHz. DSA8200 optical modules provide complete optical test solutions with superior system fidelity from 125 Mb/s to 43 Gb/s and beyond. [. . . ] The 80A05 and 80A07 can also serve as the Clock Recovery module for the 80C12 Optical Sampling module. 80A06 PatternSync Module The 80A06 PatternSync Trigger module, when used in combination with 80SJNB software, enables characterizing jitter, noise, and BER performance of high-speed serial designs from 1 Gb/s to 60 Gb/s data rates. It extends the capability of the DSA8200 sampling oscilloscope by creating a pattern trigger from any data-related clock a recovered clock, user-supplied clock, sub-clock, or super-clock. The PatternSync Trigger module is programmable to pattern lengths of up to 223 bits and accepts a user-supplied clock signal from 150 MHz to 12. 5 GHz. The 80A06 module is required with the DSA8200 when using 80SJNB Advanced Jitter, Noise, and BER Analysis software package. This module can be used in combination with the 82A04 Phase Reference module for the best time-base accuracy or for acquisition of signals under SSC (Spread Spectrum Clocking).
80A07 Clock Recovery Module 80A07 recovers clocks from serial data streams for all of the most common electrical standards in the continuous 100 Mb/s to 12. 5 GB/s range. Auto-locking capability is selectable from the user interface or programmatic interface, so the design and test engineers can search and lock onto signals of undefined or unknown data rate. The module accepts either single-ended or differential signals as its input, providing clock recovery for both. The signal(s) is/are then passed on to the output connectors and can be connected to sampling module(s) for differential or single-ended sampling. 80A07 offers complete configurability and state-of-the-art specifications and is the preferred solution for most serial data standards due to excellent stability, superior jitter and slew rate tolerance for recovering clocks from stressed or degraded signals, and unequaled PLL bandwidth and roll-off shape control for either Golden PLL compliance testing or custom PLL response. 80A07 also locks on spread-spectrum signals. The 80A07 can also serve as the Clock Recovery module for the 80C12 Optical Sampling module. P80318 Differential Handheld TDR Probe The P80318 is an 18 GHz 100 input impedance differential TDR hand probe. This probe enables high-fidelity impedance measurements of differential transmission lines. The adjustable probe pitch from 0. 5 mm to 4. 2 mm enables a wide variety of differential line spacing and impedances. The P80318 probe also includes two precision SMA cables with parallel control lines that provides the 80A02 module the control for EOS/ESD protection. P8018 Single-ended Handheld TDR Probe The P8018 Handheld TDR Probe is a 20 GHz, 50 input impedance, single-ended passive probe that provides a high-performance solution for electrical sampling, TDR circuit board impedance characterization, and high-speed electrical signal analysis applications. The P8018 probe also includes a precision SMA cable and parallel control line that provides the 80A02 module the control for EOS/ESD protection. 80A02 EOS/ESD Protection Module The 80A02 EOS/ESD Protection module protects the sampling bridge of Tektronix electrical sampling module inputs from damage by electrostatic charge. The 80A02 is intended for use in applications such as electrical TDR circuit board testing and cable testing where large static charges can be stored in the DUT. When used with the matching P8018 20 GHz single-ended handheld probe or the P80318 differential handheld probe (both with probe tip pressure actuating feature) the 80A02 provides a superior technique and performance capability for electrical module EOS/ESD protection of acquired electrical signals and TDR measurements (two 80A02 modules required for differential applications).
www. tektronix. com
11
Data Sheet
80A03 TekConnect Probe Interface Module The 80A03 provides probe power and control for up to two Tektronix P7000 Series probes. The 80A03 is powered through the oscilloscope and requires no user adjustments or external power cords. [. . . ] P8018 TDR probe recommended Enables the use of two Tektronix P7000 Series TekConnectTM probes on the DSA8200 or 8000 Series sampling oscilloscopes Phase Reference module for low-jitter acquisition (with or without trigger). Accepts signals from 2 GHz to 25 GHz (external filter might be required below 8 GHz), or to 60 GHz with Option 60G Electrical Clock Recovery module. Applicable to electrical signals and for the 80C12 50 Mb/s - 2. 700 Gb/s 2. 700 Gb/s - 3. 188 Gb/s Rate of 4 Gigabit Fibre Channel 4. 250 Gb/s 3. 267 Gb/s - 4. 250 Gb/s 4. 900 Gb/s - 6. 375 Gb/s 9. 800 Gb/s - 12. 60 Gb/s PatternSync module for 80SJNB jitter analysis package. Programmable divider for creating a trigger pulse from patterns up to 223 in length Electrical Clock Recovery module. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX DSA8200
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX DSA8200 will begin.