Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TEKTRONIX ECO422D SD-HD. We hope that this TEKTRONIX ECO422D SD-HD user guide will be useful to you.
Lastmanuals help download the user guide TEKTRONIX ECO422D SD-HD.
Manual abstract: user guide TEKTRONIX ECO422D SD-HDDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] Detection on individual channels may be disabled, giving the option of disabling changes to the backup unit on failure of signals not critical to the facility operation. When operated in the switch-on-fault mode, the ECO422D will automatically select the backup sync source should any of the primary inputs fail. However, in the unlikely event both sync sources are faulty, the ECO422D will not alternate between the two sources. [. . . ] This flexibility makes the ECO422D ideal for both the mixed-format and all-digital television facility.
Data Sheet
Characteristics
Inputs and Outputs
Return Loss
Channels 1-6: 30 dB, 0 to 10 MHz. 12 dB at 360 MHz (15 dB typical) when selected. ELSW): 30 dB, 0 to 10 MHz.
Insertion Loss
Power Source
Mains Ranges
Voltage: 100 to 240 VAC, ±10%. Power consumption: 25 W maximum.
Environmental
Temperature
Operating: 0 °C to +40 °C, IEC1010-1 compliance. Nonoperating: -40 °C to +65 °C.
Altitude
Channels 1-6: 0. 2 dB, DC to 10 MHz. In a frequency range of 10 MHz to 1. 5 GHz, the instrument approximates less than 20 meters of Belden 1694A cable. ELSW): 0. 3 dB, DC to 10 MHz
Maximum Switched Voltage
Operating: To 6562 feet (2000 meters), IEC1010-1 compliance.
Regulatory
EMC Certified to the EMC Directive 89/336/EEC. Safety
Approved to: UL3111-1, CAN/CSA-C22. 2 No. 1010. 1. Complies with: EN61010-1, IEC1010-1.
All channels: ±5 V Channels 4-6 (Opt. ELSW): ±1 V (only for the tri-level sync and analog black-burst signals). Maximum Switched Current 100 mA.
Crosstalk (Unselected input to output or channel to channel)
Physical Characteristics
Dimension mm in.
Height Width Depth
Weight
44 483 561
kg
1. 734 19. 0 22. 1
lb.
Channels 1-6: -60 dB to 10 MHz. Relay Switch Time Time that it takes for the relays to switch and settle. ELSW only) Time that it takes for the channel to switch and settle. Amplitude Detection The ECO422D will determine a fault condition exists when the input signal is less than 2 dB from the nominal level. The following are the amplitude ranges for the various types of input signals that will result in a fault condition.
Black Burst
Net Shipping
4. 9 8. 3
10. 8 18. 3
Ordering Information
ECO422D
Changeover Unit. G3 Complete Care 3 Years (includes loaner, scheduled calibration and more) Opt. [. . . ] Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX ECO422D SD-HD
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX ECO422D SD-HD will begin.