[. . . ] Mixed Signal Oscilloscopes
MSO5000, DPO5000 Series Data Sheet
53 Automated Measurements, Waveform Histograms, and FFT Analysis for Simplified Waveform Analysis TekVPI® Probe Interface supports Active, Differential, and Current Probes for Automatic Scaling and Units 10. 4 in. (264 mm) Bright XGA Display with Touch Screen Small Footprint and Lightweight Only 8. 12 in. (6. 7 kg)
Connectivity
Two USB Host Ports on the Front Panel and Four on the Rear Panel for Quick and Easy Data Storage, Printing, and Connecting USB Peripherals USB Device Port on the Rear Panel for Easy Connection to a PC or GPIB Control with an Adapter
Features & Benefits
Key Performance Specifications
2 GHz, 1 GHz, 500 MHz, and 350 MHz Bandwidth Models Up to 10 GS/s Real-time Sample Rate on One or Two Channels and up to 5 GS/s on All Four Channels Up to 250 Megapoint Record Length with MultiView ZoomTM >250, 000 wfms/s Maximum Waveform Capture Rate with FastAcqTM FastFrame Segmented Memory Acquisition Mode with >310, 000 Frames per Second Capture Rate Standard Passive Voltage Probes with Less than 4 pF Capacitive Loading and 500 MHz or 1 GHz Analog Bandwidth 16 Digital Channels (MSO Series) User-selectable Bandwidth Limit Filters for Better Low-frequency Measurement Accuracy Suite of Advanced Triggers
Integrated 10/100/1000BASE-T Ethernet Port for Network Connection and Video Out Port to Export the Oscilloscope Display to a Monitor or Projector Microsoft® Windows 7 64-bit Operating System for Easy Connectivity and Integration into Your Environment LXI Class C Compliant
Mixed Signal Design and Analysis (MSO Series)
Automated Triggering and Decode on Parallel Buses Per-channel Threshold Settings MagniVuTM High-speed Acquisition provides 60. 6 ps Fine Timing Resolution on Digital Channels
Optional Serial Triggering and Analysis
Automated Serial Triggering and Decode Options for I2C, SPI, RS-232/422/485/UART, and USB Automated Serial Decode and Vehicle Network Monitoring of CAN and LIN
Ease-of-Use Features
Wave Inspector® Controls provide Easy Navigation and Automated Search of Waveform Data MyScope® Custom Control Windows and Right Mouse Click Menus for Exceptional Efficiency
Optional Technology Specific Analysis
Software Solutions provide Built-in Domain Expertise for Ethernet and USB 2. 0 Compliance Testing, Jitter, Timing, Eye Diagrams, Power, and DDR Memory Bus Analysis Limit and Mask Testing provide Quick Insight into Signal Characteristics
Data Sheet
all channels and an optional record length of up to 250M points on two channels. With Wave Inspector® controls for rapid waveform navigation, and more than 10 optional software and analysis packages for common technologies and in-depth analysis tasks, the MSO/DPO5000 Series from Tektronix provides the feature-rich tools you need to simplify and speed debug of your complex design.
Comprehensive Features Speed Every Stage of Debug
The MSO/DPO5000 Series offers a robust set of features to speed every stage of debugging your design from quickly discovering an anomaly and capturing it, to searching your waveform record for the event and analyzing its characteristics and your device's behavior.
Discover Fast waveform capture rate - over 250, 000 wfm/s - maximizes the probability of capturing elusive glitches and other infrequent events.
Feature-rich Tools for Debugging Mixed Signal Designs
With the MSO/DPO5000 Mixed Signal Oscilloscope Series, you can analyze up to 20 analog and digital signals with a single instrument to quickly find and diagnose problems in complex designs. [. . . ] MyScope control windows benefit all oscilloscope users, eliminating the ramp-up time that many face when returning to the lab after not using an oscilloscope for a while, and enabling power users to be far more efficient. Floating Licenses Floating licenses offer an alternative method to manage your Tektronix asset. Floating licenses allow license-key enabled options to be easily moved among all your MSO/DPO5000, DPO7000, and DPO/DSA/MSO70000 Series of Tektronix oscilloscopes. Floating licenses are available for many license-key enabled options. To order a floating version of an option license add "DPOFL-" prefix to the option name. DPOFL-ET3) Check www. tektronix. com for additional information about floating license options.
Compact Form Factor A compact, portable form factor allows the MSO/DPO5000 Series to be easily moved between labs and, with a depth of just 8. 12 in. (206 mm), it saves you valuable space on your test bench. Additionally the 5U rack height makes the MSO/DPO5000 Series an ideal choice for ATE applications where rack space is limited. TekVPI® Probe Interface The TekVPI probe interface sets the standard for ease of use in probing. TekVPI probes feature status indicators and controls, as well as a probe
10
www. tektronix. com
Mixed Signal Oscilloscopes -- MSO5000, DPO5000 Series
Capture data into Microsoft Excel using the unique Excel toolbar, and create custom reports using the Word toolbar.
Remote Operation and Extended Analysis There are many ways to connect to your MSO/DPO5000 Series oscilloscope to conduct extended analysis. The first makes use of the
Windows Remote Desktop capability connect directly to your oscilloscope and operate the user interface remotely through the built-in Remote Desktop. A second way to connect is through Tektronix OpenChoice® software which makes use of the fast embedded bus, transferring waveform data directly from acquisition to analysis applications on the Windows desktop at much faster speeds than conventional GPIB transfers. Industry-standard protocols, such as TekVISATM interface and ActiveX controls are included for using and enhancing Windows applications for data analysis and documentation. IVI-COM instrument drivers are included to enable easy communication with the oscilloscope using GPIB, serial data, and LAN connections from programs running on the instrument or an external PC. Or, use the Software Developer's Kit (SDK) to help create custom software to automate multistep processes in waveform collection and analysis with Visual BASIC, C, C++, MATLAB, LabVIEW, LabWindows/CVI, and other common Application Development Environments (ADE). Microsoft® Excel and Word toolbars are included to simplify data capture and transfer directly to these programs running on the Windows desktop. A third way to connect to your oscilloscope is through NI LabVIEW SignalExpress Tektronix Edition, enabling you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming.
www. tektronix. com
11
Data Sheet
Characteristics
Vertical System Analog Channels
Characteristic MSO5034 DPO5034 MSO5054 DPO5054 MSO5104 DPO5104 MSO5204 DPO5204
Input Channels Analog Bandwidth (3 dB) Rise Time (Calculated) DC Gain Accuracy Bandwidth Limits Input Coupling Input Impedance Input Sensitivity Vertical Resolution Max Input Voltage, 1 M Max Input Voltage, 50 Position Range Delay between any Two Channels (Typical) Offset Range 1 mV/div - 50 mV/div 50. 5 mV/div - 99. 5 mV/div 100 mV/div - 500 mV/div 505 mV/div - 995 mV/div 1 V/div - 5 V/div 5. 05 V/div - 10 V/div Offset Accuracy Channel-to-Channel Isolation (Any two channels at equal Vertical Scale settings) (Typical)
350 MHz 1 ns
4 500 MHz 1 GHz 2 GHz 700 ps 350 ps 175 ps ±1. 5%, derated at 0. 10%/°C above 30 °C Depending on instrument model: 1 GHz, 500 MHz, 350 MHz, 250 MHz, and 20 MHz AC, DC 1 M ±1%, 50 ±1% 1 M: 1 mV/div to 10 V/div 50 : 1 mV/div to 1 V/div 8 bits (11 bits with Hi Res) 300 VRMS CAT II, with peaks ±425 V For <100 mV/div derate at 20 dB/decade above 100 kHz to 30 VRMS at 1 MHz, 10 dB/decade above 1 MHz For 100 mV/div derate at 20 dB/decade above 3 MHz to 30 VRMS at 30 MHz, 10 dB/decade above 30 MHz 5 VRMS, with peaks ±20 V ±5 divisions 100 ps (50 , DC coupling and equal V/div at or above 10 mV/div)
1 M: ±1 V 50 : ±1 V 1 M: ±0. 5 V 50 : ±0. 5 V 1 M: ±10 V 50 : ±10 V 1 M: ±5 V 50 : ±5 V 1 M: ±100 V 50 : ±5 V 1 M: ±50 V 50 : NA ±(0. 005 × |offset position| + DC Balance) Note: Both position and constant offset term must be converted to volts by multiplying by the appropriate volts/div term 100:1 at 100 MHz and 30:1 at >100 MHz up to the rated BW
Vertical System Digital Channels
Characteristic All MSO5000 Models
Input Channels Thresholds Threshold Selections User-defined Threshold Range Threshold Accuracy Maximum Input Voltage Input Dynamic Range
16 Digital (D15 - D0) Per-channel Thresholds TTL, ECL, User ±40 V
±(100 mV + 3% of threshold setting) ±42 Vpeak 30 Vp-p 200 MHz 10 Vp-p >200 MHz Minimum Voltage Swing 400 mV Input Impedance 100 k Probe Loading 3 pF Vertical Resolution 1 bit
12
www. tektronix. com
Mixed Signal Oscilloscopes -- MSO5000, DPO5000 Series
Horizontal System Analog Channels
Characteristic MSO5034 DPO5034 MSO5054 DPO5054 MSO5104 DPO5104 MSO5204 DPO5204
Maximum Sample Rate (All channels) Maximum Sample Rate (1 or 2 channels) Maximum Equivalent Time Sampling Rate Maximum Record Length with Standard Configuration Maximum Record Length with Option 2RL Maximum Record Length with Option 5RL Maximum Record Length with Option 10RL Maximum Duration at Highest Real-Time Sample Rate Time Base Range Time Resolution (in ET/IT mode) Time Base Delay Time Range Channel-to-Channel Deskew Range Trigger Jitter (RMS) Time Base Accuracy
5 GS/s --
5 GS/s -- 400 GS/s 12. 5M 25M 50M 125M 25 ms 250 ps/div to 1000 s/div 2. 5 ps/div 5 divisions to 5000 s ±75 ns
5 GS/s 10 GS/s
5 GS/s 10 GS/s
12. 5M (4 ch) 25M (1 or 2 ch) 25M (4 ch) 50M (1 or 2 ch) 50M (4 ch) 125M (1 or 2 ch) 125M (4 ch) 250M (1 or 2 ch)
10 psRMS for Edge trigger type 100 psRMS for all Non-edge trigger types ±5 ppm over any 1 ms interval
Horizontal System Digital Channels
Characteristic All MSO5000 Models
Trigger System
Characteristic Description
Maximum Sample Rate (Main) Maximum Record Length (Main) Maximum Sample Rate (MagniVu) Maximum Record Length (MagniVu) Minimum Detectable Pulse Width Channel-to-Channel Skew (typical) Maximum Input Toggle Rate
500 MS/s (2 ns resolution) 12. 5M Standard Up to 40M with Record Length options 16. 5 GS/s (60. 6 ps resolution) 10k points centered around the trigger 1 ns 200 ps 500 MHz at minimum input swing; higher toggle rates can be achieved at higher amplitudes
Main Trigger Modes Trigger Coupling Trigger Holdoff Range
Trigger Sensitivity
Auto, Normal, and Single DC, AC, HF Rej (attenuates >50 kHz), LF Rej (attenuates <50 kHz), Noise Reject (reduces sensitivity) 250 ns to 8 s
Internal DC Coupled
For 1 M: 1 mV/div to 4. 98 mV/div: 0. 75 div from DC to 50 MHz, increasing to 1. 3 div at instrument bandwidth 5 mV/div: 0. 40 div from DC to 50 MHz, increasing to 1 div at instrument bandwidth For 50 : 0. 40 div from DC to 50 MHz, increasing to 1 div at instrument bandwidth External (Auxiliary Input) 200 mV from DC to 50 MHz, increasing to 500 mV at 1 M 250 MHz
Trigger Level Range
Any Channel ±8 divisions from center of screen External (Auxiliary Input) ±8 V Line Fixed at about 50% of line voltage
www. tektronix. com
13
Data Sheet
Trigger Modes
Mode Description
Mode
Description
USB (Optional)
Edge Glitch Runt Width Timeout Transition Setup/Hold Pattern
State Video
Trigger Sequences
A/B Sequence Event Trigger Types Trigger Delay by Time 4 ns to 8 s Trigger Delay by Events 1 to 4, 000, 000 events I2C (Optional) Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I2C buses up to 10 Mb/s SPI (Optional) Trigger on SS or data on SPI buses up to 10 Mb/s RS-232/422/485/UART Trigger on Start Bit, End of Packet, Data, and Parity Error (Optional) up to 10 Mb/s
Positive or negative slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and noise reject Trigger on or reject glitches of positive, negative, or either polarity. Programmable glitch width is 4 ns minimum to 8 s maximum Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Trigger on width of positive or negative pulse either within or outside of selectable limits (4 ns to 8 s) Trigger on an event which remains high, low, or either, for a specified time period (4 ns to 8 s) Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative, or either Trigger on violations of both setup time and hold time between clock and data present on any two input channels Trigger when any logical pattern of signals goes false or stays true for specified period of time (4 ns to 1 s). Pattern (AND, OR, NAND, NOR) specified for all analog and digital input channels defined as High, Low, or Don't Care Any logical pattern of analog channels and digital channels (MSO models) clocked by edge on another channel. Trigger on rising or falling clock edge Trigger on all lines, specific line number, odd, even, or all fields on NTSC, PAL, SECAM, and HDTV 480p/60, 576p/50, 875i/60, 720p/30, 720p/50, 720p/60, 1080/24sF, 1080i/50, 1080p/25, 1080i/60, 1080p/24, 1080p/25, 1080p/50, 1080p/60, Bi-level, Tri-level Main, Delayed by Time, Delayed by Events. [. . . ] For example, DPO-UP DDRA.
*5 Requires TekVPI® to TekProbe BNC adapter (TPA-BNC).
Accessories
Accessory Description
Option
Description
077-0076-xx 077-0010-10 077-0063-05 SIGEXPTE TPA-BNC TEK-USB-488 HCTEK54 RMD5000 119-7083-xx 119-6297-xx 119-7766-xx 065-0851-xx K420
Service Manual Programmer Manual Performance Verification and Specifications Manual NI LabVIEW SignalExpress Tektronix Edition Software (Full Version) TekVPI-to-TekProbe BNC Adapter GPIB-to-USB Adapter Hard Transit Case Rackmount Kit Mini Keyboard (USB interface) Full-size keyboard with 4-port USB hub External DVD R/W Drive Removable HD Spare with rotational media Oscilloscope Cart
To upgrade record length:
RL02E RL05E RL010E RL25E RL210E RL510E DDRA*1 DJAE ET3*2 LT MTM PWR SR-COMP SR-EMBD SR-USB USB*3 VNM MSOE
From Standard Configuration to Opt. 2RL Configuration From Standard Configuration to Opt. 5RL Configuration From Standard Configuration to Opt. DJA Jitter and Eye Analysis Tools - Advanced (DPOJET) Add Opt. [. . . ]