User manual TEKTRONIX RFM210

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TEKTRONIX RFM210. We hope that this TEKTRONIX RFM210 user guide will be useful to you.

Lastmanuals help download the user guide TEKTRONIX RFM210.


Mode d'emploi TEKTRONIX RFM210
Download
Manual abstract: user guide TEKTRONIX RFM210

Detailed instructions for use are in the User's Guide.

[. . . ] User Manual RFM210 DVB-T Measurement Receiver 071-1098-00 This document applies to firmware version FW0722 Rev04 and above. Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service. www. tektronix. com Copyright © Tektronix, Inc. [. . . ] END is the END Level that should be entered into the RFM210 LEVEL field. RFM210 DVB-T Measurement Receiver User Manual 5- 51 Calibration Mode Example END Calculation As an example, suppose the RFM210 MER measurement is 29. 18 dB (calibration DISABLEd) and the Reference receiver MER measurement is 35. 0 dB. The calculation of the END level would be: END = 10 log 10 -29. 18 10 - 10 -35. 0 = 30. 5 dB 10 Now enter 30. 5 under Calibration LEVEL, and select Calibration ENABLE. The RFM210 MER will now read approximately 35 dB. Trial and Error Determination of END In this method, repeated trial values of END LEVEL are entered until the RFM210 corrected MER reads identically to that of the Reference receiver. Select Calibration ENABLE, and choose a trial END LEVEL. Selecting the starting trial value is simplified by noting that LEVEL is always greater than the RFM210 uncorrected MER value. Press the ESCAPE key once, and observe the MER reading. If it is lower than the reference receiver value, re-enter the Calibration menu and lower the LEVEL. If the MER is higher than the reference receiver, raise the LEVEL. This procedure converges quite quickly and has the advantage of requiring no calculation. Note that the END value is specific to a given RF channel. Calibration mode is individually set on each channel, and the unique END Value for that channel must be determined if Calibration is to be used. When Calibration is enabled, the MER reading may drift more, especially if there is a substantial difference between the reference receiver and uncorrected RFM210 MER readings. To get the same measurement stability as when Calibration is disabled, the number of symbols should be increased. For example, for 2K systems, if 200 symbols are selected with Calibration disabled, then between 300 and 400 symbols should be used with Calibration enabled. 5- 52 RFM210 DVB-T Measurement Receiver User Manual Specifications Technical Specifications Table 6- 1: RFM210 technical specifications Subject Mains Rear panel label Line Voltage Function Mains AC supply Specification 95 - 240 VAC, 0. 7 - 0. 3 A, 50/60 Hz, 35 W Fuse Rating 1. 6 A, , slow blow type Tuner RF IN Frequency Range* RF Input Level* Frequency Accuracy Channel Bandwidth (Specific to version) Typical Noise Figure Input Impedance Typical Input Return Loss Baseband Signals BASEBAND INPUT Low IF input available to accept external input 46 - 860 MHz (VHF-- UHF) - 10 to - 77 dBm (-- 20 to - 55 dBm Optimum) Double Conversion 6, 7 or 8 MHz 9 dB 75 10 dB 3. 429 MHz (6 MHz BW) 4. 0 MHz (7 MHz BW) 4. 571 MHz (8 MHz BW) Input level - 10 dBm 50 Input level - 10 dBm 50 Input gain adjustment range - 5 dBm to - 20 dBm 3. 429 MHz 4. 0 MHz 4. 571 MHz (6 MHz BW) (7 MHz BW) (8 MHz BW) BASEBAND INPUT GAIN BASEBAND OUTPUT Baseband Input Gain adjustment potentiometer Low IF output available for external monitoring Baseband Output Gain adjustment potentiometer DVB - ASI TS High Priority DVB - ASI TS Low Priority or HP Priority in non-hierarchical mode DVB - SPI (LVDS) TS High Priority DVB - SPI (LVDS) TS Low Priority or HP Priority in non-hierarchical mode BASEBAND OUTPUT GAIN MPEG2 Transport p Streams (TS) DVB-- ASI OUT HP DVB-- ASI OUT LP (HP) DVB-- SPI HP OUT DVB-- SPI LP (HP) OUT Output level typically - 10 dBm 50 Output gain adjustment range - 5 dBm to - 20 dBm ASI Transport Stream 75, 800 mV signal SPI Transport Stream Low Voltage Differential Signalling Output RFM210 DVB-T Measurement Receiver User Manual 6- 1 Technical Specifications Table 6- 1: RFM210 technical specifications (Cont. ) Subject COFDM Demodulator Rear panel label Function Modulation Systems Carriers Supported Viterbi FEC Rates Guard Intervals Hierarchical Modes Specification QPSK 16QAM 64QAM 2K/ 8K DVB-- T 1/2, 2/3, 3/4, 5/6, 7/8 1/32, 1/16, 1/8, 1/4 Non-Hierarchical and Hierarchical Modes supported with simultaneous HP and LP TS available Reed Solomon (204, 188) and Viterbi Correction Status of TPS, FEC Interfering PAL Analog Carrier 75 , 3. 5 V peak typical 75 , 3. 5 V logic signal 75 , 3. 5 V peak typical 300 mV signal typical 75 , 3. 5 V peak typical 75 , 0. 5 V peak typical 100 , 5 V peak typical 100 , 5 V peak typical MER dB MER Average % MER Peak dB BER Pre Viterbi BER Post Viterbi Ratio in dBs Mean and Deviation Imbalance in % Error in º In dBs In º RMS Loss of TX Sync Errors remaining post-Reed Solomon Frequency Response, Group Delay, Impulse Response via PC application Error Correction Synchronization Monitoring DVB-- T input level Max Channel Monitoring 1. Ch Channell S State Mode Md X/TRIG Y/W Z VGA Monitor Ethernet TR 101 290 Measurement VGA PRIMARY TEST Constellation (X Axis) Channel State Synchronization Constellation (Y Axis) Channel State Modulation Intensity (Z Axis) VGA Output 10base-- T Ethernet Ethernet Monitor MER Modulation Error Ratio BER Bit Error Ratio S/N Signal to Noise STE System Target Error AI Amplitude Imbalance QE Quadrature Error CS Carrier Suppression PJ Phase Jitter SF Sync Failure UCE Uncorrectable Errors Channel Response 6- 2 RFM210 DVB-T Measurement Receiver User Manual Technical Specifications Table 6- 1: RFM210 technical specifications (Cont. ) Subject Mechanical Rear panel label Function Height Depth Width Weight Environmental Ratings g Operating Temperature Operating Humidity Operating Altitude Equipment Class * Specification Standard 1U (44 mm) 400 mm Standard 19 inch Rack Mounting 4. 5 kg +5° C to +35° C 20% to 80% non-- condensing 2000 m (6500 ft. ) maximum Environmental testing as per Equipment Class 5 See following Notes Notes Tuner Frequency Range The COFDM tuner accepts RF signals in bands VHF and UHF (470 MHz to 860 MHz). The channel plan held within each unit is specific and therefore will determine the channels the receiver will demodulate. Where the allocated channel plan includes upper or lower offsets to the standard channels, these are selectable as defined channels. RF Input Level The RFM210 receiver has a wide input range of over the VHF/UHF bands from - to - dBm. The front-panel Carrier level display is derived from -10 -77 the Input AGC of the receiver and all bars should be completely full for best measurement. The RF input level should be within the range - to - dBm, to ensure -20 -55 reliable MER measurements. This requirement is illustrated in the graph below. The measured MER in this application was approximately 29 dB. [. . . ] A swab is useful for cleaning in narrow spaces around the controls and connectors. Do not use abrasive compounds on any part of the instrument. Avoid getting moisture inside the instrument during external cleaning and use only enough solution to dampen the cloth or swab. Use a 75% isopropyl alcohol solution as a cleanser and rinse with deionized water. Repacking for Shipment If an instrument is to be shipped to a Tektronix field office for repair, attach a tag to the instrument showing the following: H H H Owner's name and address Serial number Description of the problem(s) encountered and/or service required. The RFM210 DVB-T Measurement Receiver is shipped in cartons designed to provide it with the maximum protection. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX RFM210

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX RFM210 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag