Quickly and easily capture waveforms with advanced triggering.
See all the details other oscilloscopes might miss with Tektronix proprietary digital real-time sampling.
Performance You Need at a Price You Can Afford
The TDS2000C Digital Storage Oscilloscope Series provides you with affordable performance in a compact design. Packed with standard features including USB connectivity, 16 automated measurements, limit testing, data logging, and context-sensitive help the TDS2000C Series oscilloscopes help you get more done, in less time.
Digital Precision for Accurate Measurements
With up to 200 MHz bandwidth and 2 GS/s maximum sample rate, no other digital storage oscilloscope offers as much bandwidth and sample rate for the price. Tektronix proprietary sampling technology provides real-time sampling with a minimum of 10X oversampling on all channels, all the time to accurately capture your signals. [. . . ] The built-in data logging feature means you can set up your oscilloscope to save user-specified triggered waveforms to a USB memory device for up to 8 hours.
www. tektronix. com
3
Data Sheet
and waveform data into the stand-alone desktop application or directly into Microsoft Word and Excel. Alternatively, if you prefer not to use your PC, you can simply print your image directly to any PictBridge-compatible printer.
Connect Your Bench for Intelligent Debug
Every TDS2000C Series oscilloscope ships with an included copy of the Limited Tektronix Edition of National Instrument's LabVIEW SignalExpress for basic instrument control, data logging, and analysis. SignalExpress supports the range of Tektronix bench instruments*2 enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design.
Easily capture, save, and analyze measurement results with included National Instrument's LabVIEW SignalExpress, Limited Tektronix Edition software.
Performance You Can Count On
In addition to industry-leading service and support, every TDS2000C Series oscilloscope comes backed with a Lifetime Warranty*1 as standard.
*1 Limitations apply. For terms and conditions, visit www. tektronix. com/lifetimewarranty. *2 For a complete listing of Tektronix instruments supported by NI LabVIEW Signal Express, visit www. tektronix. com/signalexpress.
Easy PC Connectivity Easily capture, save, and analyze measurements results by connecting to your PC with the rear-panel USB device port and the included copy of OpenChoice PC Communications Software. Simply pull screen images
4
www. tektronix. com
Digital Storage Oscilloscopes -- TDS2000C Series
Characteristics
TDS2000C Series Digital Storage Oscilloscopes
TDS2001C TDS2002C TDS2004C TDS2012C TDS2014C TDS2022C TDS2024C
Display (QVGA LCD) Bandwidth*3 Channels External Trigger Input Sample Rate on Each Channel Record Length Vertical Resolution Vertical Sensitivity DC Vertical Accuracy Vertical Zoom Maximum Input Voltage Position Range Bandwidth Limit Input Coupling Input Impedance Time Base Range Time Base Accuracy Horizontal Zoom
I/O Interfaces
TFT 50 MHz 2
TFT 70 MHz 2
TFT 70 MHz 4
TFT 100 MHz 2 Included on all models 2. 0 GS/s
TFT 100 MHz 4
TFT 200 MHz 2
TFT 200 MHz 4
500 MS/s
1. 0 GS/s
1. 0 GS/s
2. 0 GS/s
2. 0 GS/s
2. 0 GS/s
2. 5k points at all time bases on all models 8 bits 2 mV to 5 V/div on all models with calibrated fine adjustment ±3% on all models Vertically expand or compress a live or stopped waveform 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz 2 mV to 200 mV/div +2 V >200 mV to 5 V/div +50 V 20 MHz for all models AC, DC, GND on all models 1 M in parallel with 20 pF 5 ns to 50 s/div 2. 5 ns to 50 s/div 2. 5 ns to 50 s/div 50 ppm Horizontally expand or compress a live or stopped waveform USB host port on front panel supports USB flash drives USB device port on back of instrument supports connection to PC and all PictBridge-compatible printers Optional (2) 2. 5k point reference waveforms (2) 2. 5k point (2) 2. 5k point (4) 2. 5k point (2) 2. 5k point 64 GB 96 or more reference waveforms per 8 MB 10 front-panel setups 4000 or more front-panel setups per 8 MB 128 or more screen images per 8 MB (the number of images depends on file format selected) 12 or more Save All operations per 8 MB A single Save All operation creates 3 to 9 files (setup, image, plus one file for each displayed waveform) (4) 2. 5k point (2) 2. 5k point (4) 2. 5k point
5 ns to 50 s/div
5 ns to 50 s/div
2. 5 ns to 50 s/div
2. 5 ns to 50 s/div
USB Ports GPIB
Nonvolatile Storage
Reference Waveform Display Waveform Storage without USB Flash Drive Maximum USB Flash Drive Size Waveform Storage with USB Flash Drive Setups without USB Flash Drive Setups with USB Flash Drive Screen Images with USB Flash Drive Save All with USB Flash Drive
*3 Bandwidth is 20 MHz at 2 mV/div, all models.
www. tektronix. com
5
Data Sheet
Acquisition Modes
Mode Description
Waveform Math
Characteristic Description
Peak Detect Sample Average Single Sequence Roll
High-frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 s/div to 50 s/div Sample data only Waveform averaged, selectable: 4, 16, 64, 128 Use the Single Sequence button to capture a single triggered acquisition sequence At acquisition time base settings of >100 ms/div
Operators FFT
Add, Subtract, Multiply, FFT Windows: Hanning, Flat Top, Rectangular 2048 sample points
Sources 2-channel models CH1 CH2, CH2 CH1, CH1 + CH2, CH1 × CH2 4-channel models CH1 CH2, CH2 CH1, CH3 CH4, CH4 CH3, CH1 + CH2, CH3 + CH4, CH1 × CH2, CH3 × CH4
Autoset Menu Trigger System
Characteristic Description
Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset.
Signal Type Autoset Menu Choices
Trigger Modes
Auto, Normal, Single Sequence
Trigger Types
Trigger Description
Edge (Rising/Falling) Video Pulse Width (or glitch)
Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM) Trigger on a pulse width less than, greater than, equal to, or not equal to, a selectable time limit ranging from 33 ns to 10 s
Square Wave Sine Wave Video (NTSC, PAL, SECAM)
Single Cycle, Multicycle, Rising or Falling Edge Single Cycle, Multicycle, FFT Spectrum Field: All, Odd, or Even Line: All or Selectable Line Number
Autorange
Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from point to point, or when the signal exhibits large changes.
Display Characteristics
Characteristic Description
Trigger Source
Characteristic Description
2-channel Models 4-channel Models
CH1, CH2, Ext, Ext/5, AC Line CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line
Display Interpolation Display Types Persistence Format
QVGA Active Color TFT Sin(x)/x Dots, vectors Off, 1 s, 2 s, 5 s, infinite YT and XY
Trigger View
Displays trigger signal while Trigger View button is depressed.
Multiple-language User Interface and Context-sensitive Help
Characteristic Description
Trigger Signal Frequency Readout
Provides a frequency readout of the trigger source.
Languages Available
English, French, German, Italian, Japanese, Korean, Portuguese, Russian*4, Simplified Chinese, Spanish, Traditional Chinese
*4 Requires Russian firmware, indicated by "RUS" suffix.
Cursors
Characteristic Description
Environmental and Safety
Characteristic Description
Types Measurements
Amplitude, Time T, 1/T, V
Automatic Waveform Measurements
Period, Frequency, +Width, Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, RMS, Cycle RMS, Cursor RMS, Duty Cycle, Phase, Delay
Temperature Operating Nonoperating Humidity Operating and nonoperating Altitude Operating and nonoperating Electromagnetic Compatibility Safety
0 to +50 °C 40 to +71 °C Up to 80% RH at or below +40 °C Up to 45% RH up to +50 °C Up to 3, 000 m Meets Directive 2004/108/EC, EN 61326-2-1 Class A; Australian EMC Framework UL61010-1:2004, CSA22. 2 No. For terms and conditions visit www. tektronix. com/lifetimewarranty. *6 Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the data sheet of each probe and accessory model for its unique warranty and calibration terms.
Power Plug Options
Option Description
A0 A1 A2 A3 A5 A6 A10 A11 A99
North America Universal Euro United Kingdom Australia Switzerland Japan China India No power cord or AC adapter
www. tektronix. com
7
Data Sheet
User Manual Options
Translated front-panel overlays included with their respective user manuals.
Option Description
Recommended Probes
Probe Description
L0 L1 L2 L3 L4 L5 L6 L7 L8 L9 L10
English manual French manual Italian manual German manual Spanish manual Japanese manual Portuguese manual Simple Chinese manual Standard Chinese manual Korean manual Russian manual
Recommended Accessories
Accessory Description
TPP0101 10X Passive Probe, 100 MHz bandwidth TPP0201 10X Passive Probe, 200 MHz bandwidth P2220 1X/10X Passive Probe, 200 MHz bandwidth P6101B 1X Passive Probe (15 MHz, 300 VRMS CAT II rating) P6015A 1000X High-voltage Passive Probe (75 MHz) P5100 100X High-voltage Passive Probe (250 MHz) P5200 High-voltage Active Differential Probe (25 MHz) P6021 15 A, 60 MHz AC-current Probe P6022 6 A, 120 MHz AC-current Probe A621 2000 A, 5 to 50 kHz AC-current Probe A622 100 A, 100 kHz AC/DC Current Probe/BNC TCP303/TCPA300 150 A, 15 MHz AC/DC Current Probe/Amplifier TCP305/TCPA300 50 A, 50 MHz AC/DC Current Probe/Amplifier TCP312/TCPA300 30 A, 100 MHz AC/DC Current Probe/Amplifier TCP404XL/TCPA400 500 A, 2 MHz AC/DC Current Probe/Amplifier
TEK-USB-488 SIGEXPTE AC2100 HCTEK4321 RM2000B 071-1075-xx 071-1828-xx 174-4401-xx
GPIB-to-USB converter National Instruments SignalExpress Tektronix Edition Interactive Measurement Software Professional Version Soft Carrying Case for Instrument Hard Plastic Carrying Case for Instrument (requires AC2100) Rackmount Kit Programmer Manual English Only Service Manual English Only USB host to device cable, 3 ft. long
Service Options*6
Option Description
C3 C5 D1 D3 D5 CA1
Calibration Service 3 Years Calibration Service 5 Years Calibration Data Report Calibration Data Report 3 Years (with Opt. [. . . ] Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. [. . . ]