User manual TEKTRONIX TDS3054C DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TEKTRONIX TDS3054C. We hope that this TEKTRONIX TDS3054C user guide will be useful to you.

Lastmanuals help download the user guide TEKTRONIX TDS3054C.


Mode d'emploi TEKTRONIX TDS3054C
Download
Manual abstract: user guide TEKTRONIX TDS3054CDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Fast waveform capture rates on a continuous basis save time by quickly revealing the nature of faults so advanced triggers can be applied to isolate them. Real-time intensity grading highlights the details about the history of a signal's activity, making it easier to understand the characteristics of the waveforms you've captured. Unlike other comparable oscilloscopes, the history remains even after the acquisition is stopped. Quickly Debug and Characterize Signals with DRT Sampling Technology and sin(x)/x Interpolation The TDS3000C Series combines unique digital real-time (DRT) sampling technology with sin(x)/x interpolation to allow you to accurately characterize a wide range of signal types on all channels simultaneously. [. . . ] DPOs provide 3 dimensions of signal information in real time: Amplitude, time, and the distribution of amplitude over time High-frequency and random glitch capture. Captures glitches as narrow as 1 ns (typical) using acquisition hardware at all time base settings Monitors the incoming signals on all channels and alerts the user to any waveform that deviates from the normal waveform being acquired Sample data only Waveform averaged, selectable from 2 to 512 Min-max values acquired over one or more acquisitions Use the Single Sequence button to capture a single triggered acquisition sequence at a time Amplitude, Time Cursors Automatic Measurements Display any four measurements from any combination of waveforms. Or display all measurements with measurement snapshot feature. Measurements include Period, Frequency, +Width, -Width, Rise time, Fall time, +Duty cycle, -Duty cycle, +Overshoot, High, Low, Max, Min, Peak-to-peak, Amplitude, Mean, Cycle mean, RMS, Cycle RMS, Burst width, Delay, Phase, Area*1, Cycle Area*1 Measurement Statistics Mean, Min, Max, Standard deviation. Requires TDS3AAM application module Thresholds User-definable thresholds for automatic measurements; settable in percent or voltage Gating Isolate a specific occurrence within an acquisition to take measurements, using either the screen or cursors *1 Requires TDS3AAM application module. Trigger System Characteristic Description Waveform Math Characteristic Description Main Trigger Modes Auto (supports Roll Mode for 40 ms/div and slower), Normal, Single Sequence B Trigger Trigger after time or events Trigger After Time Range 13. 2 ns to 50 s 1 to 9, 999, 999 events Trigger After Events Range Arithmetic FFT Advanced Math*1 Trigger Types Trigger Description Add, subtract, multiply, and divide waveforms Spectral magnitude. Set FFT vertical scale to Linear RMS or dBV RMS, and FFT window to Rectangular, Hamming, Hanning, or Blackman-Harris Integrate, Differentiate, Define extensive algebraic expressions including analog waveforms, math functions, scalars, up to two user-adjustable variables and results of parametric measurements. For example: (Intg (Ch1-Mean(Ch1)) × 1. 414 × VAR1) Note: Requires TDS3AAM application module. Edge Video Extended Video Pulse Width (or Glitch) Runt Slew Rate Pattern State Comm Alternate Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject Trigger on all lines or individual lines, odd/even or all fields on NTSC, PAL, SECAM Trigger on specific lines in broadcast and non-broadcast (custom) standards and on analog HDTV formats (1080i, 1080p, 720p, 480p). Requires TDS3VID or TDS3SDI application module Trigger on a pulse width <, >, =, to a selectable time limit ranging from 39. 6 ns to 50 s Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Trigger on pulse edge rates that are either faster or slower than a set rate. Edges can be rising, falling, or either Specifies AND, OR, NAND, NOR when true or false for a specific time Any logic state. Triggerable on rising or falling edge of a clock. Logic triggers can be used on combinations of 2 inputs (not 4) Provides isolated pulse triggering required to perform DS1/DS3 telecommunications mask testing per ANSI T1. 102 standard. Requires TDS3TMT application module Sequentially uses each active channel as a trigger source *1 Requires TDS3AAM application module. Waveform Processing Characteristic Description Autoset Deskew Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo autoset Channel-to-channel deskew ±10 ns may be manually entered for better timing measurements and more accurate math waveforms Display Characteristics Characteristic Description Display Type Display Resolution Interpolation Waveform styles Graticules Format 6. 5 in. (165. 1 mm) liquid-crystal TFT color display 640 horizontal × 480 vertical pixels (VGA) Sin(x)/x Dots, vectors, variable persistence, infinite persistence Full, grid, crosshair, and frame. A99 North America Universal Euro United Kingdom Australia Switzerland Japan China India No power cord Language Options Option Description Opt. L99 English French Italian German Spanish Japanese Portuguese Simplified Chinese Traditional Chinese Korean Russian No manual 6 www. tektronix. com Digital Phosphor Oscilloscopes -- TDS3000C Series Recommended Accessories Accessory Description Recommended Probes Probe Description TDS3GV TDS3AAM TDS3LIM TDS3TMT TDS3VID TDS3SDI TDS3BATC TDS3CHG AC3000 HCTEK4321 RM3000 SIGEXPTE Service Manual TNGTDS01 GPIB, VGA, RS-232 interface Advanced Analysis Module. Adds extended math capability, arbitrary math expressions, measurement statistics, and additional automated measurements Limit Testing Module. Adds custom waveform limit testing capabilities Telecom Mask Testing Module. Adds pass/fail compliance of ITU-T G. 703 and ANSI T1. 102 standards, custom mask testing, and more Extended Video Analysis Module. [. . . ] and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX TDS3054C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX TDS3054C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag