Detailed instructions for use are in the User's Guide.
[. . . ] Saves time, removes complexity, and reduces measurement uncertainty Analysis Tools for Debugging and Validating Today's Digital Systems FPGA DDR A Broad Selection of Microprocessor and Bus Support MIPI CSI and DSI Debug
Features & Benefits
Comprehensive Set of Signal Integrity Tools that Allow You to Quickly Isolate, Identify, and Debug Complex Signal Integrity Issues Glitch Trigger and Storage Allows you to trigger on and highlight potential signal integrity problems. Not only can the TLA6000 Series trigger on the problem, but by highlighting suspected problems in red, you will be able to easily determine which signals you need to investigate further iCapture Route the suspected signal to the analog output of the TLA6000 using the exclusive Tektronix iCapture feature. This eliminates the need to double-probe with an oscilloscope probe, reducing time to debug iView Time-correlated view of both logic analyzer and oscilloscope data to trace the SI problem across the digital and analog domain
Applications
Digital Hardware Validation and Debug Monitoring, Measurement, and Optimization of Digital Hardware Performance Embedded Software Integration, Debug, and Verification
Data Sheet
Efficiently Debug and Validate Your Digital System at a Price You Will Like!
The affordable TLA6000 Series of logic analyzers offer the performance needed to debug, validate, and optimize the functionality of your digital system. [. . . ] (38. 1 cm) diagonal Type: Active-matrix color TFT LCD with backlight Resolution: 1024×768 Both the front-panel and one external display can be used simultaneously at 1024×768 resolution General-purpose knob with dedicated hotkeys and knobs for horizontal and vertical scaling and scrolling Available with Option 18
External Signal Output
Simultaneous Display Capability Front Panel
External Signal Input
Touch Screen
Power
Voltage Range/Frequency: 90-250 V AC at 45-66 Hz, 100-132 V AC at 360-440 Hz Input Current: 7 A maximum at 90 V AC (70 A surge) Power Consumption: 750 W maximum
Integrated View (iViewTM) Capability
Characteristic Description
TLA Mainframe Configuration Requirements Number of Tektronix Oscilloscopes that can be Connected to a TLA System External Oscilloscopes Supported TLA Connections Oscilloscope Connections Setup Data Correlation
GPIB-iView (Opt. 1C) requires TLA Application Software 5. 0 or greater 1
Environmental
Characteristic Description
Temperature More than 100. For a complete listing of currently supported oscilloscopes, please visit our website http://www. tektronix. com/iview USB, Trigger In, Trigger Out, Clock Out GPIB, Trigger In, Trigger Out, Clock In (when available) for the GPIB-iView cable (Opt. 1C) iViewTM external oscilloscope wizard automates setup After oscilloscope acquisition is complete, the data is automatically transferred to the TLA and time correlated with the TLA acquisition data The oscilloscope and TLA data is automatically deskewed and time correlated when using the iViewTM external oscilloscope cable 2m Altitude Safety Humidity
Operating: +5 °C to +45 °C Nonoperating: 20 °C to +60 °C 20% to 80% Operating: 30 °C; 80% relative humidity (29 °C maximum wet-bulb temperature) Nonoperating: 8% to 80% (29 °C maximum wet-bulb temperature) Operating: 1, 000 ft. Can be as wide as any group, must be grouped according to specified order of significance From 8 ns before to 7 ns after clock edge in 125 ps increments. This range may be shifted towards the positive region by 0 ns, 4 ns, or 8 ns From 7 ns before to 8 ns after clock edge in 125 ps increments. This range may be shifted towards the positive region by 0 ns [+8, 8] ns, 4 ns [+12, 4] ns, or 8 ns [+16, 0] ns Any data sample MagniVu position can be set from 0% to 60% centered around the MagniVu trigger Global (conditional), by state (start/stop), block, by trigger action, or transitional. Also force main prefill selection available
Trigger Action Types
Maximum Triggerable Data Rate Trigger Sequence Rate Counter/Timer Range Counter Rate Timer Clock Rate Counter/Timer Latency Range Recognizers
Setup-and-Hold Violation Recognizer Setup Time Range Setup-and-Hold Violation Recognizer Hold Time Range Trigger Position MagniVu Trigger Position Storage Control (Data qualification)
www. tektronix. com
5
Data Sheet
Ordering Information
TLA6202 TLA6203 TLA6204
68-channel Logic Analyzer module, 8 GHz timing, 235 MHz state, 2 Mb record length. Options for up to 128 Mb record length and/or up to 450 MHz state. 102-channel Logic Analyzer module, 8 GHz timing, 235 MHz state, 2 Mb record length. Options for up to 128 Mb record length and/or up to 450 MHz state. 136-channel Logic Analyzer module, 8 GHz timing, 235 MHz state, 2 Mb record length. Options for up to 128 Mb record length and/or up to 450 MHz state. All Include: Mini Keyboard (119-7275-xx), Optical Wheel Mouse (119-7054-xx), Front-panel cover (200-4939-xx), TLA Application Software CD (063-3881-xx), Certificate of Traceable Calibration. Please specify probe, power, language, and service options when ordering.
Recommended Accessories
Accessory Description
LACART (2-shelf cart) K4000 (3-shelf cart) 016-1522-xx 020-2664-xx 650-4815-xx
Logic Analyzer Cart Wheeled Transport Case Rackmount Kit Additional Removable Hard Drive Assembly; No SW
Power Plug Options
Option Description Order Number
Instrument Options
Option Description
1P 2P 3P 1S 2S 3S 45 AM 18 1C PO TL
Add full complement of P6810 (General-purpose) probes Add full complement of P6434 (Mictor) probes. Includes SQUIRE adapters Add full complement of P6960 (D-Max) probes Increase to 8 Mb record length Increase to 32 Mb record length Increase to 128 Mb record length Increase state speed to 450 MHz Add full analog mux control Add touch screen Add iView cable Add accessory pouch Add TekLink cable
A0 A1 A2 A3 A4 A5 A6 A10 A11 A99
North America Universal Euro United Kingdom Australia 240 V, North America Switzerland Japan China India No power cord or AC adapter
161-0104-00 161-0104-06 161-0104-07 161-0104-14 161-0104-08 161-0167-00 161-A005-00 161-0306-00 161-0324-00 --
Language Options
Option Description
L0 L5 L10 L99
English Manual Japanese Manual Russian Manual No Manual
6
www. tektronix. com
Tektronix Logic Analyzers -- TLA6000 Series
Service Options
Option Description
Upgrades
Provides a single calibration event or coverage for the designated calibration interval, whichever comes first Calibration Service, 3 Years Calibration Service, 5 Years Calibration Data Report Calibration Data Report, 3 Years (with Option C3) Calibration Data Report, 5 Years (with Option C5) Repair Service, 3 Years Repair Service, 5 Years On-site Service, 1 Year On-site Service, 3 Years (with R or C options) Repair Service Coverage, 1-year Post Warranty Repair Service Coverage, 2-year Post Warranty Repair Service Coverage, 3 Years (includes product warranty period). [. . . ] Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. [. . . ]