Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TELTONIKA TM2 AT. We hope that this TELTONIKA TM2 AT user guide will be useful to you.
Lastmanuals help download the user guide TELTONIKA TM2 AT.
Manual abstract: user guide TELTONIKA TM2 ATCOMMANDS MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] TM2 AT Commands Manual
History Company was established on 15th of April 1998. ompany started with production of telecommunication devices. In 2001 company expanded its fields of activity by starting design and manufacturing of electronical systems for wireless data transfer. In 2002 contract of partnership and collaboration was signed with company Pro-Sign GmbH (Germany), considering design and representation of graphic programming interface iCon-L in Eastern Europe. [. . . ] The settings which may be changed are described in the chapter related to the &V command. 14. 10. 2 Syntax Command syntax: AT&Y[<value>]
Command
Possible responses OK or +CME ERROR: <error>
Set command AT&Y1
14. 10. 3 Defined values <value> may be: - 0: selects profile 0 - 1: selects profile 1 - 2: selects the default factory settings. If the parameter is not inserted, the value is set to 0.
14. 11 Request identification information I
14. 11. 1 Description This action command causes the DCE to transmit one or more lines of information text, determined by the manufacturer, followed by a final result code. 14. 11. 2 Syntax Command syntax: ATI[<value>] Command Possible responses
99
TM2 AT Guide Command
Set command
Possible responses Manufacturer 3 OK or +CME ERROR: <error>
ATI3
14. 11. 3 Defined values <value> may be in range 0-9; for each value an other text provided by the manufacturer will be displayed.
14. 12 Request manufacturer Identification +GMI
14. 12. 1 Description This action command causes the DCE to transmit one or more lines of information text, determined by the manufacturer, which allows to identify the manufacturer. 14. 12. 2 Syntax Command syntax: AT+GMI Command AT+GMI Note: get manufacturer identification
Test command
Possible responses <manufacturer> OK or +CME ERROR: <error> OK
AT+GMI=?
14. 13 Request model identification +GMM
14. 13. 1 Description This command gives the model identification. 14. 13. 2 Syntax Command syntax: AT+GMM Command AT+GMM Note: get model identification Test command AT+GMM=?Possible responses <model> OK or +CME ERROR: <error> OK
14. 14 Request revision identification +GMR
14. 14. 1 Description This command gives the revised version of the mobile station.
100
TM2 AT Guide
14. 14. 2 Syntax Command syntax: AT+GMR Command AT+GMR Note: get revision version
Test command
Possible responses <revision> OK or +CME ERROR: <error> OK
AT+GMR=?
14. 15 Request product serial number identification +GSN
14. 15. 1 Description This command gets the product serial number, known as IMEI (International Mobile Equipment Identity) of the MS. 14. 15. 2 Syntax Command syntax: AT+GSN Command AT+GSN Note: get the IMEI
Test command
Possible responses <IMEI> OK or +CME ERROR: <error> OK
AT+GSN=?
14. 16 DTE-DCE character framing +ICF
14. 16. 1 Description This command sets the local serial port start-stop (asynchronous) character framing which is used in the information interchange between DCE and DTE. The value 0 is correspondent to the auto-detect case. Please note: - due to hardware characteristics the frame recognition can be present in conjunction with the autobauding recognition only i. e. the AT+ICF command is effective if AT+IPR is set to 0 only. In this case the AT+ICF returns the 0 value; - outside the autobauding conditions the AT+ICF=0 answers OK but it does not switch the system to automatically frame recognition and it doesn't take actions. command will return the current value of the frame format. The AT+IPR=0 command instead force the AT+ICF to be 0; - under the autobauding conditions, the AT+ICF command provided with a value different than 0 will answer ERROR since is not possible to force a frame type in those automatically conditions; - if a data frame format refers to a frame without parity (ex. format 3), the parity value returned by the AT+ICF?command has no meaning;
101
TM2 AT Guide
- - the stop bit number cannot be automatically recognized i. e. if the system is switched from the 8N2 to the autodetect feature and a 1 stop bit frame is provided at the serial port, unpredictable behaviour of the system can occur; 14. 16. 2 Syntax Command syntax: AT+ICF=[<format>[, <parity>]] Command
Set command
Possible responses OK or +CME ERROR: <error> +ICF: <format>, <parity> OK +ICF: (0-3, 5), (0-1) i. e. lists of supported <format> and <parity> OK
AT+ICF=3, 1
Read command
AT+ICF?
Test command
AT+ICF=?14. 16. 3 Defined values <format> may be: - 0: auto detect - 1: 8 data 2 stop - 2: 8 data 1 parity 1 stop - 3: 8 data 1 stop - 5: 7 data 1 parity 1 stop <parity> may be: - 0: odd - 1: even
14. 17 DTE-DCE local flow control +IFC
14. 17. 1 Description This command controls the operation of local flow control between DTE and DCE used when data are sent or received. 14. 17. 2 Syntax Command syntax: AT+IFC=[<DCE_by_DTE>[, <DTE_by_DCE>]] Command
Set command
Possible responses OK or +CME ERROR: <error> +IFC: <DCE_by_DTE>, <DTE_by_DCE> OK +IFC: (0-2), (0-2) i. e. lists of supported <DCE_by_DTE> and <DTE_by_DCE>
AT+IFC=2, 2
Read command
AT+IFC?
Test command
AT+IFC=?
102
TM2 AT Guide Command Possible responses OK
14. 17. 3 Defined values <DCE_by_DTE> may be: - 0: none - 1: DC1/DC3 on circuit 103 (XON/XOFF) - 2: circuit 133 (RTS) <DTE_by_DCE> may be: - 0: none - 1: DC1/DC3 on circuit 104 (XON/XOFF) - 2: circuit 106 (CTS)
14. 18 Set flow control \Q
14. 18. 1 Description This command controls the operation of local flow control between DTE and DCE used when data are sent or received. 14. 18. 2 Syntax Command syntax: AT\Q[<value>] Command
Set command
Possible responses OK or +CME ERROR: <error>
AT\Q3
14. 18. 3 Defined values <value> may be: - 0: no flow control - 1: DC1/DC3 on circuit 103 and 104 (XON/XOFF) - 2: DTE_by_DCE on circuit 106 (CTS) - 3: DCE_by_DTE on circuit 133 (RTS and DTE_by_DCE on circuit 106 (CTS)
14. 19 Fixed DTE rate +IPR
14. 19. 1 Description This command specifies the data rate at which the DCE will accept commands. [. . . ] [15]GSM 04. 12 Digital cellular telecommunications system (Phase 2+); Short Message Service Cell Broadcast (SMSCB) Support on Mobile Radio Interface. [16]3GPP TS27. 007 Technical Specification Group Terminals; AT command set for User Equipment (UE); V3. 11. 0 [17]3GPPTS27. 005 Technical Specification Group Terminals; Use of Data Terminal Equipment - Data Circuit terminating Equipment (DTE-DCE) interface for Short Message Services (SMS) and Cell Broadcast Service (CBS); V4. 1. 0 [18]GSM 07. 60 Digital cellular telecommunication system (Phase 2+); GPRS Service description; stage 2 [19]GSM 11. 11 Digital cellular telecommunications system (Phase 2+); Specification of the Subscriber Identity Module Mobile Equipment (SIM ME) interface [20]ITU-T V. 25ter ITU-T V. 25 ter Recommendation: Data Communications over the Telephone Network; Serial asynchronous automatic Dialling and control. [21]ITU-T T. 32 ITU-T Recommendation T. 32 Asynchronous Facsimile DCE Control - Service Class 2 [22]3GPP TS 22. 030 Digital cellular telecommunications system (Phase 2+); Universal Mobile Telecommunications System (UMTS); Man-Machine Interface (MMI) of the User Equipment (UE) [23]ISO 639 (1988) Code for the representation of names of languages
20. 2 Internal
Title [24]FOAT User Guide Doc ID DN07. MK. DO. 000002
171
TM2 AT Guide
21 Appendices
21. 1 Mobile Termination error result code +CME ERROR
<err> Meaning 0 phone failure 1 no connection to phone 2 3 4 5 10 11 12 13 14 15 16 20 21 22 23 24 25 26 27 30 31 100 103 106 107 111 112 113 132 133 134 149 148 150 1500 1501 1502 1503 1504 1520 phone-adaptor link reserved operation not allowed operation not supported PH-SIM PIN required SIM not inserted SIM PIN required SIM PUK required SIM failure SIM busy SIM wrong incorrect password memory full invalid index not found memory failure text string too long invalid characters in text string dial string too long invalid characters in dial string no network service network timeout unknown illegal MS illegal ME GPRS services not allowed PLMN not allowed Location area not allowed roaming not allowed in this location area service option not supported requested service option not subscribed service option temporarily out of order PDP authentication failure unspecified GPRS error invalid mobile class Wrong GPIO identifier Set GPIO default error Select GPIO mode error Read GPIO error Write GPIO error Wrong ADC identifier all +C. . commands described in GSM07. 07 +CLCK, +CPWD, +CPIN, ATD*. . . #. . . [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TELTONIKA TM2 AT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.