User manual THEBEN LU361PE-S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THEBEN LU361PE-S. We hope that this THEBEN LU361PE-S user guide will be useful to you.

Lastmanuals help download the user guide THEBEN LU361PE-S.


Mode d'emploi THEBEN LU361PE-S
Download
Manual abstract: user guide THEBEN LU361PE-S

Detailed instructions for use are in the User's Guide.

[. . . ] â· Patented adjustment design of sensor - Resolve dead angle of most current selling ceiling sensor in the market. â· Two relays for switching outputs (LU 361 PE-S) - One relay for lighting and another voltage free relay for HVAC (Heating, Ventilation, Air conditioner), or security camera, etc. Short impulse: Provide short triggering. [. . . ] And refer to wiring diagram to connect it in parallel with the first sensor (LU 361 PE2) in power box (See Fig. Refer to wiring diagram to connect wiring into power box terminal then replace protecting-cover and tighten it with screws (Voir Fig. Organize all wirings, then fix the power box with screws and mount it in the ceiling (Voir Fig. Insert two spring-clip pins into hole and press the sensor upward, then spring-clip pins will automatically stick on ceiling. â· Adjust sensor position and assure its bottom fixed tightly on ceiling (See Fig. Wipe gently with a clean and dry cloth if the sensor surface is dirty. Slightly pull out sensor head with a screwdriver at OPEN mark before sensor head adjustment (See Fig. You can adjust sensor head to meet your detection coverage. LED can be regarded as indicator when performing a walk test without connecting any loads. Walk Test The purpose of the walk test is to check and adjust the motion sensor detection range. Turn "METER" knob to "7m", "TIME 1" knob to "test", then you can carry out a walk test and it is uncontrolled by LUX (See Fig. When first time switches the power n or power is re-supplied again after the power is shut off, LED will turn on for 40 secs. During the time of warming up, there is no output for LOAD I if it is in test & impulse mode, otherwise it has permanent output as LOAD II. Once any activities are detected after warming up period (40 secs. [. . . ] Keep away from detection zone to avoid activating sensor while doing the test. Please check whether the power supply and load are connected correctly. Avoid aiming the sensor toward any heat sources such as air conditioners, electric fans, heaters or any highly reflective surfaces. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THEBEN LU361PE-S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THEBEN LU361PE-S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag