User manual THERMADOR 15-12-596C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THERMADOR 15-12-596C. We hope that this THERMADOR 15-12-596C user guide will be useful to you.

Lastmanuals help download the user guide THERMADOR 15-12-596C.


Mode d'emploi THERMADOR 15-12-596C
Download
Manual abstract: user guide THERMADOR 15-12-596C

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS MANUAL PROFESSIONAL RANGES ALL-GAS MODELS ­ PRG304, PRG36 AND PRG48 DUAL-FUEL MODELS - PRDS304, PRDS36 AND PRDS48 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION, ELECTRICAL CONNECTIONS, GAS CONNECTIONS, AND GROUNDING MUST COMPLY WITH ALL APPLICABLE CODES. IMPORTANT: Save these instructions for the Local Electrical Inspector's use. INSTALLER: Please leave these Installation Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. [. . . ] These screws will prevent rotation of the channel. Note: A number of mounting holes are provided in the Adjustable Anti-Tip Channel. Be certain to use the hole that enables the channel to engage the mounting bracket when the range is in its final installed position. For ranges that are to be installed flush against a rear wall, use the first hole in the Adjustable Anti-Tip Channel, such that the short portion of the channel extends out from the bottom of the range flange and the long portion is hidden beneath the range. 13 PRG36 Floor Mount PLAN VIEW Anti-Tip Channel Mounting Bracket PRG304: 2-3/4" PRG36: 4-5/8" Anti-Tip Channel Mounting Bracket STEP 4: INSTALLING ANTI-TIP DEVICE STEP B: Set the bracket on the floor and turn it until it is oriented properly. The long channel should be on the top with the free end facing towards you, one set of mounting flanges should be resting horizontally on the floor, and the other set of mounting flanges should be positioned vertically facing the rear. STEP C: Slide the bracket to the desired position. "B") spacing from the side wall to the center line of the closest bracket mounting hole is as shown in the chart above and in Figures 14 and 15. STEP D: If you plan to mount the bracket to the rear wall, slide the bracket back until it is positioned against the rear wall. If you plan to mount the bracket to the floor, position the bracket such that the center line of the mounting holes in the horizontal bracket flanges are 7/16" in front of the rear edge of the range side panel when the range is in its final installed position. STEP E: With the bracket properly positioned, use the bracket as a template and mark the location of the selected four (4) mounting holes. STEP F: Drill four (4) holes at the marked locations. STEP G: Using the four (4) screws provided, securely fasten the bracket. STEP H: Carefully slide the range into position. FOR THE ANTI-TIP DEVICE TO ENGAGE THE RANGE, THE REAR EDGE OF THE RANGE SIDE PANEL MUST BE WITHIN 2" OF THE VERTICAL MOUNTING FLANGE OF THE ANTI-TIP BRACKET, REMOVE ANY LOOSE ITEMS SUCH AS GRATES AND BURNER CAPS FROM THE TOP OF THE RANGE, THEN CAREFULLY TILT THE RANGE FORWARD TO ENSURE THAT THE ANTI-TIP DEVICE ENGAGES TO PREVENT TIPPING. Min. A Max. B Max, up to 2" Shown from Left Side Wall SIDE VIEW FIG. 15 PRDS Floor Mount PLAN VIEW 716" Shown from Left Side Wall SIDE VIEW Page 14 STEP 5: GAS REQUIREMENTS AND HOOKUP Verify the type of gas being used at the installation site. As shipped from the factory, all units are configured for use on natural gas. For use with propane gas, the unit must be converted. Field conversion for use with propane must only be done by qualified service personnel. Contact the dealer where the unit was purchased or Thermador (800/735-4328). The field conversion kit for all Professional Gas (PRG series) ranges is Thermador Model PROGASLPKIT. The field conversion kit for all Professional Dual Fuel (PRDS series) ranges is Thermador Model STARLPKIT. [. . . ] Burner caps properly seated into burner bases with alignment pins engaged. Grill components properly seated (not all models). Refer to Use & Care Manual for Grill details. Bezels centered on burner knobs, and knobs turn freely. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 15-12-596C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 15-12-596C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag