User manual THERMADOR 20-02-275I

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THERMADOR 20-02-275I. We hope that this THERMADOR 20-02-275I user guide will be useful to you.

Lastmanuals help download the user guide THERMADOR 20-02-275I.


Mode d'emploi THERMADOR 20-02-275I
Download
Manual abstract: user guide THERMADOR 20-02-275I

Detailed instructions for use are in the User's Guide.

[. . . ] Conversion for use with propane gas can be made using a kit, Model NLPKIT5, P/N 35-00-622. A qualified technician or installer can convert the cooktop. This kit includes instructions for adjusting valves and regulator and contains new burner jets. This appliance is equipped with an intermittent/interrupted ignition device. ! [. . . ] THE THIRD GROUND PRONG SHOULD NOT UNDER ANY CIRCUMSTANCES, BE CUT OR REMOVED. 2 Three Prong Receptacle Receptacle Box Cover Plate Three Prong Plug Fig. 3 Two Prong Receptacle Cover Plate Alternate Grounding Method - See Fig. 3. If installing a properly grounded wall receptacle is impossible at the time of installation, consult your local electrical inspector for permission to connect a temporary adapter (with polarized blades) which could be plugged into your present 2-wire receptacle. If this is done, you must attach the lug and/or the green adapter wire to the receptacle cover plate screw. Ground from it to a grounded metal cold water pipe, * see Fig. You must permanently ground the adapter before connecting the appliance to the power supply. CAUTION: Attaching the adapter ground wire to the wall receptacle cover screw does not ground the appliance unless the cover screw is grounded through the house wiring. If there is any doubt as to whether the wall receptacle is properly grounded, the customer should have it checked by a qualified electrician. Cold water pipe must have metal continuity to the electrical ground and not be interrupted by plastic, rubber or other electrically insulating connectors (including water meter or pump) without adding a jumper wire at these connections. 4. Page 4 Ground Wired Ground Wire Three Prong Adaptor Grounded Cold Three Water Metal Pipe Prong Plug Fig. 4 Wire Clamp Metal Clamp Water Pipe Meter STEP FOUR: PREPARE CABINET 1. See Cabinet Considerations under Step One: Before You Begin, page 3. Fig. 5 CABINET AND COUNTERTOP DIMENSIONS 1" Min. to Wall "B" 21-3/4" 2. Instructions are based on Standard American cabinets 36" high x 24" deep. If nonstandard cabinets are used care should be taken to alter dimensions accordingly. All cutout dimensions given in figure 5 have to be precisely followed. Plan the installation of the unit so that the power cord, gas shut-off valve and gas pressure regulator are accessible from the front of cabinet. If a drawer is installed, directly under the cooktop, its depth should be no greater than 15 inches. This unit has been Design Certified for installation in countertop near adjacent walls and projecting surfaces constructed of combustible materials. The minimum horizontal distance from the back edge of the cooktop to adjacent vertical combustible wall, and minimum horizontal distance from front edge of cooktop to front side of countertop is 1 inch. The minimum horizontal distance from the sides of the cooktop to the adjacent vertical combustible walls are as follows: left and right side walls is 3 inches and to the rear wall is 1 inch. "F" 3" Deep from Top of Counter 3" Min. [. . . ] Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilating engineer for your specific ventilation requirements. For the most detailed information, refer to installation instructions accompanying product or write Thermador indicating the model number. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 20-02-275I

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 20-02-275I will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag