User manual THERMADOR 5060004249

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THERMADOR 5060004249. We hope that this THERMADOR 5060004249 user guide will be useful to you.

Lastmanuals help download the user guide THERMADOR 5060004249.


Mode d'emploi THERMADOR 5060004249
Download
Manual abstract: user guide THERMADOR 5060004249

Detailed instructions for use are in the User's Guide.

[. . . ] UNIVERSAL COOK'N'VENT ® INSTALLATION INSTRUCTIONS MODELS: UCV30 · UCV36 · UCV45 Rating: 120 Volt, 60 Hz. , 10. 0 Amps. For Integral Blower Installations: · Requires Integral Blower: Model # VTN600CVA · Requires Round Duct Size (6" Diam. ) · Requires Dedicated Branch Circuit Power Supply · 120 Volt AC· min. 15 Amps. , 3 prong receptacle · 60 Hz. · See Steps 3 and 5 for electrical receptacle and duct outlet location For Remote Blower Installations: · Requires Remote Blower: Model # VTR1000Q or VTR600R · Requires Duct Transition: Model # CVT314 (for 3-1/4" x 14" duct) or Model # CVT7 (for 7" Diam. Round) · Requires 4 wires and 1 ground wire connecting blower and vent · Requires Dedicated Branch Circuit Power Supply · 120 Volt · 15 Amps. , 3 prong receptacle · 60 Hz. , AC. [. . . ] · Back to back elbows and "S" turns significantly reduces air flow and are not recommended. · A short straight length of duct at the inlet of the remote blower gives the best delivery. · Transition to round duct as close to the Cook`n'Vent® as possible. 6" round duct · The use of flexible metal round duct should only be used when no other duct fitting exists. Limit use to short lengths and do not crush when making corners. · Where local codes permit, plastic pipe (PVCschedule 40 pipe or ABS pipe 7" or 8" diameter) can be used in areas of high ground moisture and in slab floors to eliminate future rusting. STEP 2 PREPARE COUNTERTOP CUTOUT For installation of the Cook'n'Vent® with a Thermador cooktop, refer to Part A and Figure 7. For installation with another brand of cooktop, refer to Part B and Figure 8. For all installations, verify cutouts will clear the inside of the front countertop support rail. The front and rear cutouts must be straight and parallel to the front edge of countertop and the rear backsplash or wall. Assure that the side cutouts are square to the front and rear cutouts. All illustrations and dimensions are based upon standard 24" deep by 36" high American style base cabinets with 25" countertops. When installing laminated or solid surface countertops such as SurellTM and Corian®, be sure to follow the countertop manufacturer's instructions regarding minimum corner radii, reinforcement of corners, etc. For overhead cabinet and cooktop side clearances consult cooktop Installation Instructions. A. INSTALLATION WITH A THERMADOR COOKTOP (FIGURE 7 AND TABLE 3) Provide an opening in the countertop as specified in Table 3. Make sure the distance from the front of the countertop to the front of the cutout is not less than dimension "SB. " Verify that the available flat countertop is greater than dimensions "OW" by "OD. " Make certain the backsplash thickness does not exceed dimension "BT". Page 7 TABLE 3 (in inches) UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS Cooktop Model No. SB is specified in the installation instructions shipped with the cooktop. Backsplash thickness must not exceed BT as calculated below: BT = 24 7/8" - SB+CO - OD - 2-1/4 (Provides 1 /8" clearance between vent and backsplash. ) A negative value for BT means countertop is too small for the installation. Verify that the available flat countertop has a width greater than OW and a depth greater than OD. OW depends on the installation: UCV30: OW equals the greater of COW or 30". UCV36: OW equals the greater of COW or 36". UCV45: OW equals the greater of COW or 45". OD is determined by: OD=COD+2-1/4". * Refer to Table 3 Notes on previous page. [. . . ] (Lost or missing wire nuts should only be replaced with: Spring type wire nuts, rated for a minimum of (2) #18ga wires and max. of (4) #14ga wires, UL & CSA rated to 600V and 302 deg. F/150 deg. 14 AWG wire Page 12 STEP 8 VERIFY INSTALLATION, OPERATION & COOKTOP ALIGNMENT Before performing this procedure, verify that all packing materials were removed from inside the lower enclosure front and that the grease filters have been properly installed. Refer to the Care and Use Manual for instructions regarding filter installation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 5060004249

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 5060004249 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag