User manual THERMADOR 9000008294

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THERMADOR 9000008294. We hope that this THERMADOR 9000008294 user guide will be useful to you.

Lastmanuals help download the user guide THERMADOR 9000008294.


Mode d'emploi THERMADOR 9000008294
Download
Manual abstract: user guide THERMADOR 9000008294

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION INSTRUCTIONS F o r T h e r m a d o r ® P r o f e s s i o n a l Indoor Grill Model PB30 Section 1: Safety Information WARNING Disconnect power before installing. Before turning power ON, be sure that all controls are in the OFF position. For Massachusetts Installations: 1. Installation must be performed by a qualified or licensed contractor, plumber or gas fitter qualified or licensed by the state, province or region where this appliance is being installed. Shut-off valve must be a "T" handle gas cock. [. . . ] All Professional® Indoor Grills are CSA approved. Figure 3a Model PB30BS ¦ Figure 3b Hood Bottom to Countertop 36" OR 48" HOOD 13" (350mm) Max. A C B Figure 4a. Wall Installation with Countertop Backsplash ¦ 18" Min. (457mm) Figure 4b. Wall Installation ¦ E F See Detail A Detail A Front face of cabinet x ¦ ¦ 1/4" (6. 4 mm) ¦ D Corner Notch Detail Refer to Detail A: x = 0" - Control panel projects 2" from front face of base cabinet. x = 5/8" - Control panel projects 1-3/8" from front face of base cabinet (rear of unit flush to wall with standard 24" deep base cabinet). x = 2" - Control panel flush with front face of base cabinet (min. 25-3/8" deep base cabinet required). 4 ¦ Custom removable access panel ¦ (762mm) to 30" to (914mm) 36" ¦ ¦ See Detail A 3/4" Min. ¦ ¦ Custom removable access panel ¦ ¦ Section 4: Ventilation Requirements It is strongly recommended that an exhaust hood be installed above the grill. Hoods that incorporate grease filters of mesh construction should not be used. Testing has shown that mesh filters can collect and hold enough grease to become a fire hazard. Downdraft ventilation should not be used. Due to the high heat capacity of this unit, and the smoke generated during grilling of foods, particular attention should be paid to the hood and ductwork installation to insure it meets local building codes. Due to the high volume of ventilation air required, a source of outside replacement (make-up) air is recommended. This is especially important for tightly sealed and insulated homes. A qualified heating and ventilating contractor should be consulted. Table 1 indicates the Thermador hoods, by model number, that are recommended for use with the indoor grill. For wall installations, the minimum hood width is 36" (915 mm) [3" (77 mm) overhang per side]. Where space permits, a wider hood may be desirable for improved ventilation performance. For best smoke capture, the lower edge of the hood Installation Type Wall Table 1 Hood PH36ZS1 PH42ZS PH48ZS PH54ZS Blower VTNl000Q Notes: 1 For wall installation where adequate space is available, the installer or user may elect to use a hood that is wider than the grill cooking surface. This may be particularly beneficial for those cases, such as a long duct run or heavy usage of the grill, in which improved capturing of the cooking exhaust is desired. should be installed a minimum of 30" (762 mm) to a maximum of 36" (915 mm) above the grill cooking surface. Minimum overhang of hood to grill on either side is 3 inches (77mm). NOTE: Ventilation hoods and blowers are designed for use with single-wall ducting. Some local building codes may require double-wall ducting. Before starting installation, consult local building codes and agencies to insure that the installation will meet local requirements. Section 5: Electrical Requirenments and Grounding Instructions The Thermador Professional® Indoor Grill uses an electronic ignition system that requires a 120 VAC, 10A, 60 Hz power supply. A properly grounded and polarized duplex outlet must be provided adjacent to the lower left rear corner of the unit. [. . . ] In the absence of a local code, the installation must conform to the National Fuel Gas Code ANSI Z223. 1/NFPA54current issue. Always use pipe dope or Teflon® tape on the pipe threads, and be careful not to apply excessive pressure when tightening the fittings. BURNER AIR ADJUSTMENT FIGURE 9 CAUTION Thermador recommends that burner adjustments be made by a qualified technician at the time of installation. Extreme care should be used when adjustments are made after installation. Improper or lack of adjustment may cause harmful by-products and may void your warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THERMADOR 9000008294

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THERMADOR 9000008294 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag