Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THOMSON MEC 310#GENSET CONTROLLER. We hope that this THOMSON MEC 310#GENSET CONTROLLER user guide will be useful to you.
Lastmanuals help download the user guide THOMSON MEC 310#GENSET CONTROLLER.
Manual abstract: user guide THOMSON MEC 310#GENSET CONTROLLER
Detailed instructions for use are in the User's Guide.
[. . . ] MEC 310
GENSET CONTROLLER
INSTALLATION AND OPERATION MANUAL
r. 0472f
PM075 Rev 2 09/08/20
9087A 198 Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Fax (604) 888-3381 E-Mail: info@thomsontechnology. com www. thomsontechnology. com
th
This description of options covers the following products: MEC 310 SW version 1. 2X. X
MEC 310 GENSET CONTROLLER
Table of Contents
1. ABOUT THIS DOCUMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 GENERAL PURPOSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INTENDED USERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 CONTENTS/OVERALL STRUCTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. WARNINGS AND LEGAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 LEGAL INFORMATION AND RESPONSIBILITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ELECTROSTATIC DISCHARGE AWARENESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SAFETY ISSUES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FACTORY SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. [. . . ] Select ALL parameters to be saved in USW project file.
5. Choose file name and where to save project file on PC
PM075 REV 2 09/08/20
Page 70
THOMSON TECHNOLOGY
MEC 310 GENSET CONTROLLER
6. Press Firmware update button and select new application software (*. A79 file)
New application software can be downloaded from www. thomsontechnology. com 7. This will force MEC 310 into boot mode (LED 1 will flash red)
If the programming should be interrupted, it's possible to force the unit back into boot mode by disconnecting Aux. Press and hold the "OFF" button. voltage and unit is into boot mode.
PM075 REV 2 09/08/20
Page 71
THOMSON TECHNOLOGY
MEC 310 GENSET CONTROLLER
Indication of boot mode: blank display and LED 1 flash red. After download of new firmware is done, saved parameters can be downloaded into unit.
9. Write to device, using "Batch job" function
PM075 REV 2 09/08/20
Page 72
THOMSON TECHNOLOGY
MEC 310 GENSET CONTROLLER
11.
Select parameters which want to be downloaded into the unit.
12. Restart unit
PM075 REV 2 09/08/20
Page 73
THOMSON TECHNOLOGY
MEC 310 GENSET CONTROLLER
GSM communication GSM communication can be used for 2 purposes: 1. Sending SMS alarm messages to up to 5 different mobile phones. The messages will be sent in clear text, representing the alarm in question (e. g. The ID represents the total numbers of sent SMS. Communicate with the MEC 310 TSP 300 software.
2.
Connection:
SMS alarm message Mobile phone
Modem RS232 connection SSP PC with TPS 300
MEC 310 GC-1
Telephone line
Service port
The connection is based on an RS232 connection to a GSM modem via the service port on the MEC 310. Since the connection on the MEC 310 is a TTL communication, the SSP interface box is needed to convert the signals to RS232. The SSP connects via a cable with SUB-D 9-pin female connector on the modem side. The easiest way to get the modem is to purchase it through a local dealer. The SIM card needed comes from your local mobile net provider. The easiest way to set the PIN code in the modem itself is to mount the SIM card in a mobile phone and change the PIN code there. The SIM card will remember the PIN code when it is installed in the modem. Siemens recommends a short power interruption (30 sec. ) once a day to prevent lock-up of the modem. The easiest way to do this is to use a 24 hour watch. Should an alarm occur during the interruption, the multi-line unit will re-transmit it when the modem starts again, so no messages are lost. [. . . ] 10001 10002 Setting
Cmd. 1 timer/start/stop Cmd. 1 timer/start/stop
Min. setting Setpoint Enable
timer M-logic
Max. setting
Stop
Factory setting
timer M-logic
OFF
ON
OFF
10010 Cmd. 1 day(s) No. 10010 Setting Cmd. 1 day(s) Setting MO TU WE TH FR SA SU MO-TU-WE-TH MO-TU-WE-TH-FR SA-SU MO-TU-WE-TH-FR-SA-SU Factory setting
X
10020 Cmd. 1 hour No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON MEC 310#GENSET CONTROLLER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON MEC 310#GENSET CONTROLLER will begin.