User manual THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS J1939

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS J1939. We hope that this THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS J1939 user guide will be useful to you.

Lastmanuals help download the user guide THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS J1939.


Mode d'emploi THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS J1939
Download
Manual abstract: user guide THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS J1939

Detailed instructions for use are in the User's Guide.

[. . . ] MEC 310 GENSET CONTROLLER Option J ­ CANbus J1939 r. 0474G PM077 Rev 1 09/08/20 9087A ­ 198 Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology. com www. thomsontechnology. com th This description of options covers the following products: MEC 310 FW version 1. 2X. X MEC 310 GENSET CONTROLLER - Option J ­ CANbus J1939 Table of Contents 1. WARNINGS AND LEGAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 LEGAL INFORMATION AND RESPONSIBILITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ELECTROSTATIC DISCHARGE AWARENESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY ISSUES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FACTORY SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. DESCRIPTION OF OPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 OPTION J. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 TERMINAL DESCRIPTION FOR MEC 310. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 MODBUS COMMUNICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 WIRING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3. [. . . ] Some parameters can only be changed using the TPS 300 programming software. The parameter list will automatically be abandoned, if no button is pressed during a 30 sec. period. PM077 R1 09/08/20 Page 14 THOMSON TECHNOLOGY MEC 310 GENSET CONTROLLER - Option J ­ CANbus J1939 Running detection During a start sequence the start relay is deactivated, if: the speed exceeds the RPM running setting the running feedback input is ON, or the measured frequency of the generator is above 30Hz, or the speed information given by the EIC communication is above the limit EICoverspeed_6010 During a stop sequence the generator is considered to be stopped, if: the speed is below the running setting the running feedback input is OFF, or the measured frequency of the generator is below 30Hz, or the speed information given by the EIC communication is below the limit EICoverspeed_6010 PM077 R1 09/08/20 Page 15 THOMSON TECHNOLOGY MEC 310 GENSET CONTROLLER - Option J ­ CANbus J1939 The J1939 warnings/shutdowns with corresponding SPN and FMI numbers in this chapter refer to those that will automatically appear in the alarm list. The alarms can be acknowledged from the display. The available alarms vary from engine type to engine type. Besides these, the entire log list can be read in the engine controller by holding the `LOG' button for 3 seconds. Caterpillar/Perkins (J1939) Warnings and shutdowns Warning/shutdown list SPN 100 102 110 172 174 190 J1939 codes FMI FMI warning shutdown 17 1 15 15 1 15 15 15 0 X X Low oil pressure Intake manifold #1 P Coolant temperature High inlet air temp. Fuel temperature Overspeed EIC yellow lamp EIC red lamp FMI indication ` ­ ` means that the alarm in question is not supported. Write commands to engine controller · Engine controls All the write commands to the engine controller (ex: speed, start/stop, etc. ) are enabled in setting 7563 (EIC Controls). Engine speed CANbus ID for speed control: 0x0c000000. J1939 TSC1. · The speed regulation is enabled in setting 2781 (Reg. output) and 7563 (EIC Controls). PM077 R1 09/08/20 Page 16 THOMSON TECHNOLOGY MEC 310 GENSET CONTROLLER - Option J ­ CANbus J1939 Cummins CM850 (J1939) Warnings and shutdowns Warning/shutdown list SPN 100 110 175 105 174 111 190 101 109 J1939 codes FMI FMI warning shutdown 18 1 16 0 16 0 16 0 16 0 18 1 16 0 1 X X Low oil pressure Coolant temperature Oil temperature Intake manifold temp Fuel temperature Coolant level low Overspeed Crankcase pressure high Coolant pressure low EIC yellow lamp EIC red lamp FMI indication ` ­ ` means that the alarm in question is not supported. Write commands to engine controller · Engine controls All the write commands to the engine controller (ex: speed, start/stop, etc. ) are enabled in setting 7563 (EIC Controls). Engine speed CANbus ID for speed control: 0x00FF69DC. For Cummins proprietary `Engine governing' EG telegram, the source address of the ML-2 controller is 0xDC/220 dec). The speed regulation is enabled in setting 2781 (Reg. output) and 7563 (EIC Controls). · · Frequency selection Nominal frequency is written automatically based on the frequency nominal setting. 50Hz is written if fNOM < 55Hz, 60Hz is written if fNOM is >55Hz. Gain setting Gain is set in menu 2773. · PM077 R1 09/08/20 Page 17 THOMSON TECHNOLOGY MEC 310 GENSET CONTROLLER - Option J ­ CANbus J1939 Detroit Diesel DDEC (J1939) Warnings and shutdowns Warning/shutdown list SPN J1939 codes FMI FMI warning shutdown X X EIC yellow lamp EIC red lamp FMI indication ` ­ ` means that the alarm in question is not supported. Write commands to engine controller · Engine controls All the write commands to the engine controller (ex: speed, start/stop, etc. ) are enabled in setting 7563 (EIC Controls). Engine speed CANbus ID for speed control: 0x0c000000. J1939 TSC1. · The speed regulation is enabled in settings 2781 (Reg. output) and 7563 (EIC Controls). PM077 R1 09/08/20 Page 18 THOMSON TECHNOLOGY MEC 310 GENSET CONTROLLER - Option J ­ CANbus J1939 Deutz EMR 2 (J1939) Warnings and shutdowns Warning/shutdown list SPN 100 110 190 J1939 codes FMI FMI warning shutdown 1 0 0 X X Low oil pressure Coolant temperature Overspeed EIC yellow lamp EIC red lamp FMI indication ` ­ ` means that the alarm in question is not supported. Write commands to engine controller · Engine controls All the write commands to the engine controller (ex: speed, start/stop, etc. ) are enabled in setting 7563 (EIC Controls). Engine speed CANbus ID for speed control: 0xc000003. For J1939 TSC1, the source address of the ML2 controller is 3. · The speed regulation is enabled in setting 2781 (Reg. output) and 7563 (EIC Controls). PM077 R1 09/08/20 Page 19 THOMSON TECHNOLOGY MEC 310 GENSET CONTROLLER - Option J ­ CANbus J1939 General J1939 (J1939) Warnings and shutdowns Warning/shutdown list SPN J1939 codes FMI FMI warning shutdown X X EIC yellow lamp EIC red lamp FMI indication ` ­ ` means that the alarm in question is not supported. Write commands to engine controller · Engine controls All the write commands to the engine controller (ex: speed, start/stop, etc. ) are enabled in setting 7563 (EIC Controls). [. . . ] Trap inlet Air filter diff press Cool filter diff press Atmospheric pressure Ambient air temp [F/10] Description 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 EIC actual % torque EIC acc. speed EIC air inlet pressure EIC exhaust gas temp. EIC coolant pressure EIC water in fuel Reserved Reserved Reserved Reserved EIC turbo oil temp. EIC trap inlet EIC Air filter diff press EIC Cool filter diff press EIC Atm press EIC Ambient air temp [%] [%] [%] [bar] [psi] [deg] [F] [H] [bar] [psi] [V] [bar] [psi] [%] [bar] [psi] [bar] [psi] [2 bits] [deg] [F] [bar] [psi] [bar] [psi] [bar] [psi] [bar] [psi] [deg] [F] 1/1 1/1 1/1 1/100 1/10 1/1 1/100 1/10 1/100 1/10 1/100 1/100 1/1 1/1 - - 1/10 1/100 - - 1/10 1/100 1/1000 1/100 1/100 1/10 - PM077 R1 09/08/20 Page 33 THOMSON TECHNOLOGY MEC 310 GENSET CONTROLLER - Option J ­ CANbus J1939 Measurement table (read only) function code 04h. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS J1939

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS J1939 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag