User manual THOMSON TS 870

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual THOMSON TS 870. We hope that this THOMSON TS 870 user guide will be useful to you.

Lastmanuals help download the user guide THOMSON TS 870.


Mode d'emploi THOMSON TS 870
Download

You may also download the following manuals related to this product:

   THOMSON TS 870 WITH TSC 80E CONTROLLER (658 ko)

Manual abstract: user guide THOMSON TS 870

Detailed instructions for use are in the User's Guide.

[. . . ] TS 870 AUTOMATIC TRANSFER SWITCHES INSTALLATION, OPERATING & SERVICE MANUAL PM062 Rev 6 08/08/01 9087A ­ 198 Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology. com www. thomsontechnology. com th TS 870 TRANSFER SWITCH TABLE OF CONTENTS 1. PRODUCT REVISION HISTORY EQUIPMENT STORAGE 2. 1. ENVIRONMENTAL CONDITIONS 1 1 1 3. NOTES TO INSTALLER 3. 1. UPSTREAM CIRCUIT PROTECTIVE DEVICES/ELECTRICAL CONNECTIONS TRANSFER SWITCHES WITH INTEGRAL OVER CURRENT PROTECTION TRANSFER SWITCHES WITH MULTI-TAP VOLTAGE CAPABILITY SYSTEM PHASING-HIGH LEG DELTA SYSTEMS REMOTE START CONTACT FIELD WIRING DIELECTRIC TESTING INSTALLATION OF OPEN TYPE TRANSFER SWITCHES 2 2 3 3 4 5 5 5 4. GENERAL DESCRIPTION 4. 1. [. . . ] The control circuit isolation plug is located on the inner side of the transfer switch enclosure door. To operate manually, insert the operating handle into the square hole on the front of the mechanism and rotate to the desired position. Remove the operating handle once operation is complete and re-insert into the handle holder on the left-hand side of the transfer switch mechanism. PM062 REV 6 08/08/01 17 Thomson Technology TS 870 TRANSFER SWITCH Automatic operation may be regained by replacing the control circuit isolation plug. With all sources of power de-energized to the transfer switch, the control circuit isolation plug can be re-connected. The drive system will operate the transfer switch to the required position. (See manual operation instruction on front of transfer switch mechanism. ) PM062 REV 6 08/08/01 18 Thomson Technology TS 870 TRANSFER SWITCH 9. TRANSFER SWITCH MECHANISM ­1000A-1200A, T-Style The transfer mechanism consists primarily of the transfer motor, a hub assembly, two operating rods and two power switching device operating yokes. The reversible transfer motor drives the hub assembly, which in turn moves the operating rods that are connected to the power switching device operating yokes. The power switching device toggles are set inside the yokes and are moved by them. There are two limit switches, which are contacted by the operating yokes (one for each direction of travel), which disconnect the transfer motor power supply when the power switching devices have attained full travel. The adjuster screws, located on the yokes determine the operating point of these limit switches. Should adjustment be required, it is advisable to consult Thomson Technology for further information. The transfer switch mechanism has three possible positions: a) b) d) Utility power switching device closed and generator power switching device open; Generator power switching device closed and utility power switching device open; Both utility and generator power switching devices open, but NEVER both utility and generator power switching devices closed at the same time. 9. 1. MANUAL OPERATION DANGER!!!!Do not open equipment until ALL power sources are disconnected This equipment must be installed and serviced only by qualified electrical personnel utilizing safe work practices and appropriate Personal Protective Equipment (PPE). Failure to do so may cause personal injury or death Isolate the transfer switch from all sources of supply before opening the enclosure for manual operation. With all sources of power de-energized to the transfer switch, the control circuit isolation plug can be unplugged to prevent subsequent operation. To operate manually, pull the release plunger and operate the handle in the desired direction. Automatic operation may be regained by replacing the isolation plug. With all sources of power de-energized to the transfer switch, the control circuit isolation plug can be re- PM062 REV 6 08/08/01 19 Thomson Technology TS 870 TRANSFER SWITCH connected. The drive system is self-engaging and will operate the transfer switch to the required position. (See manual operation instruction on front of transfer switch mechanism. ) PM062 REV 6 08/08/01 20 Thomson Technology TS 870 TRANSFER SWITCH 10. RECOMMENDED MAINTENANCE DANGER!!!!Do not open equipment until ALL power sources are disconnected This equipment must be installed and serviced only by qualified electrical personnel utilizing safe work practices and appropriate Personal Protective Equipment (PPE). Failure to do so may cause personal injury or death 10. 1. DO NOT perform dielectric tests on the equipment with the control components in the circuit. [. . . ] To change the software setting, follow the procedure below; NOTE: The TSC 80E controller does not utilize the system voltage jumpers, which are located on the printed circuit board. Any jumpers on the printed circuit board will be ignored. PASSWORD ENTRY PROCEDURE To enter the programming mode, follow the procedure as shown: 1. Press the ENTER key to obtain the Password Main Menu. The "PASSWORD ENTRY & RESETS" prompt will appear). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON TS 870

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON TS 870 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag