Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TISSOT T-TOUCH EXPERT. We hope that this TISSOT T-TOUCH EXPERT user guide will be useful to you.
Lastmanuals help download the user guide TISSOT T-TOUCH EXPERT.
Detailed instructions for use are in the User's Guide.
[. . . ] 1 sec.
or
10:10 07
T
27. 12. 07
10:10 00
T
11:32 27
11:32 00
T
11:32 27
T
a)
b)
27. 12. 07
Activate glass
10;10 00
T
10:10 00
T
11:32 27
T
11:32 00
T
11:32 27
T
Time T or T2 display (example: T)
Setting mode
: forward 1 min. (hands and display)
Validate setting a) The seconds restart at zero b) The seconds continue
december
27
SETTING > DATE
The calendar is perpetual, i. e. the number of days per month is predefined. In continuous setting, the days scroll past slowly at first, and then quicker. [. . . ] Absolute atmospheric pressure is the actual pressure D 990 at the time and place of measurement, and 995 1000 cannot be altered. Relative pressure is a 15 10 1 0 02 0 10 1005 1A * value relative to sea level, based on local absolute atmospheric pressure . Barometers and weather charts show relative pressure values. The relative pressure value depends on the climate zone set, and can be preset on the watch. The relative pressure presetting is in line with the altitude.
6
42
12
24
6
Characteristics of function Measurement range: absolute pressure: 300 hPa to 1100 hPa relative pressure: 950 hPa to 1100 hPa Accuracy: absolute pressure: ± 3 hPa relative pressure: varies with altimeter Resolution: 1 hPa Unit conversion: 1 hectoPascal [hPa] = 1 millibar [mb]
4478m
m
ALTIMETER
The altitude is displayed on the digital screen for 10 hours continuously. After 10 hours, the altimeter mode is deactivated, and the date is displayed.
1 sec.
27. 12. 07 792M
03:18h55
27. 12. 07
Activate glass
792M 2599FT
Altitude display
03:18h55
Altitude difference display
4478m
m
SETTING > ALTITUDE PRESETTING
2 sec.
or
792M 792M 795M 795M
or
795M
792M
Altitude display
792M
Setting mode
795M
: up 1 m or 3 ft : down 1 m or 3 ft
795M
Validate setting
www. tissot. ch
7/13
10
141_ E N
10
T-TOUCH EXPERT
*
m
ALTIMETER > ALTITUDE DIFFERENCE
Sequentially every 2 seconds
2 sec. 2 sec.
03:18h55
03:18h55
1188A
Total cumulative gain in altitude during elapsed time
18A5
Mean vertical speed of ascent (metres/minute or feet/minute)
Elapsed time or stopped time
2 sec. 2 sec.
03:18h55
Altitude difference display
3192d
24d5
Mean vertical speed of descent (metres/minute or feet/minute)
2 sec.
03:18h55
Back: Elapsed time or stopped time
Total cumulative loss in altitude during elapsed time
00:00h00
R
03:18h55
R
00:00h00
2 sec.
rUn 00:00h00
R
STOP 03:18h55
R
rESET 00:00h00
Reset Altitude difference meter
Start Altitude difference meter
Stop Altitude difference meter
4478m
m
GLOSSARY > ALTIMETER
We advise you to stop the altitude difference meter during rest times and then restart it, in order to obtain more accurate results.
792M
R
Description of function In altimeter mode, your T-TOUCH becomes a barometric altimeter, displaying the altitude relative to mean sea level.
Explanations 2000m This is a barometric instrument, which calculates 1500m the altitude as a function of absolute pressure 1000m (atmospheric). As the altitude rises, pressure 500m 0m drops, and vice versa. So the altimeter measures the difference between absolute pressure (atmospheric) and relative pressure (relative to sea level) to display the altitude. Your T-TOUCH is temperature compensated, and you can adjust your geographic location (hemisphere and climate zone). The altitude displayed is therefore corrected automatically. In compass mode, the digital screen displays the angle between 12 o'clock and the minutes hand.
1 sec.
27. 12. 07 337
0
300 A
0
CAL
337
0
N
27. 12. 07
Activate glass
337
0
S
3000
A
CAL
User compass calibration
3370
Back to compass display
Compass display
Azimuth display
N W S E
SETTING > COMPASS > MAGNETIC DECLINATION
2 sec. or
337
0
or
337
0
6W
0
R
2E
0
R
337
0
N
337
0
S
&0
R
W
20
R
E
3370
Validate setting
Compass display
Setting mode and magnetic declination display
: +/- 1 degree East : +/- 1 degree West
N
A
45°
COMPASS > AZIMUTH
In compass mode, your T-TOUCH enables you to define and follow an azimuth. To do so, you need only set the azimuth value and align the watch using the arrows. The 6-12 o'clock axis will indicate the heading to take.
N
300 A
0
300
0
A
300A
0
300
0
S
300o
3000
A
3000
A
3000
A
3000
A
Azimuth display
a) Turn the 6-12 o'clock axis left to align 12 o'clock with the azimuth
b) Turn the 6-12 o'clock axis right to align 12 o'clock with the azimuth
c) The 6-12 o'clock axis is aligned with the azimuth
N
A
45°
SETTING > COMPASS > AZIMUTH
2 sec.
300
0
A
300
0
A
270
or
270
0
A
0
or
A
270
0
A
N
300
0
A
S
3000
A
2700
A
2700
A
Azimuth display
Setting mode
: increase azimuth by 1 degree : decrease azimuth by 1 degree
Validate setting Back to azimuth display
www. tissot. ch
10/13
141_ E N
T-TOUCH EXPERT
*
CAL
SETTING > COMPASS > COMPASS CALIBRATION
2 sec.
CAL CAL run
CAL r un
CAL
Compass Calibration display
CAL run
Activate calibration mode glass deactivated during calibration
Turn the watch more than a complete revolution on a horizontal surface (e. g. a table) in an environment free from magnetic interference, at a rotation speed of around 30° per second. Total time: 20 seconds maximum
CAL
ok
CAL
ko
334
334
0
N
0
S
a) Calibration successful data stored
b) Calibration failed repeat calibration
Back to compass display
N
N
W S
E
A
45°
GLOSSARY > COMPASS
Azimuth
N
Compass In compass mode, your T-TOUCH indicates the True North Pole, factoring in magnetic declination.
In azimuth mode, your T-TOUCH indicates the azimuth (heading) that you need to turn to. Azimuth explanations
Heading
337
0
S
Compass explanations The vertical lines (meridians) on the Earth converge at the True North Pole (Ng), indicating its direction. The hand of a conventional compass indicates the direction of the Magnetic North Pole (Nm). The angle () between these two directions Ng and Nm is known as magnetic declination. The magnetic Ng declination value depends on your location on Nm Earth. [. . . ] Conversion formulae: Measurement range: Accuracy: Resolution: T 0C = (T 0F -32) x 5/9 T 0F = T 0C x 9/5 + 32 5°C to +55°C / 23°F to 130°F ± 1°C / ± 1. 8°F 0. 1°C/ 0. 2°F
www. tissot. ch
12/13
141_ E N
T-TOUCH EXPERT
*
SENSOR FAULT
GENERAL INFORMATION
When a function is selected and the display is cleared, it is probably due to a failure of the selected function's sensor.
To activate the functions on your T-TOUCH a gentle press on the push-buttons or touch on the glass is all that is required. The brightness of the digital display decreases when the hands are in motion.
5 sec.
R
27. 12. 07
In fast continuous setting mode, the display moves at a faster rate (e. g. for date function: months or years instead of days) than in non-continuous or normal speed setting mode (e. g. for date: days instead of months or years). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TISSOT T-TOUCH EXPERT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TISSOT T-TOUCH EXPERT will begin.