User manual TJERNLUND 950-2420 24SP200 SPILLAGE KIT 8504056 REV 1 0397

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND 950-2420 24SP200 SPILLAGE KIT 8504056 REV 1 0397. We hope that this TJERNLUND 950-2420 24SP200 SPILLAGE KIT 8504056 REV 1 0397 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND 950-2420 24SP200 SPILLAGE KIT 8504056 REV 1 0397.


Mode d'emploi TJERNLUND 950-2420 24SP200 SPILLAGE KIT 8504056 REV 1 0397
Download
Manual abstract: user guide TJERNLUND 950-2420 24SP200 SPILLAGE KIT 8504056 REV 1 0397

Detailed instructions for use are in the User's Guide.

[. . . ] DIAGRAM A1 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com 24SP200 SAFETY INTERLOCK SYSTEM (P/N 950-2420) (For Millivolt and 24 Volt Control Systems only) This Safety Interlock System may be used on conventional chimney or Power Vented appliances equipped with a draft hood, draft diverter or draft control. DIAGRAM A2 PURPOSE To provide a means for appliance shut-down in the event of flue blockage or down drafts. OPERATION The Spill Switch circuits are "normally closed" and will not affect normal appliance operation. When concentrated spillage of combustion gases occurs from the draft hood, diverter or barometric control, the Spill Switch circuit will open preventing burner operation. PARTS LIST QUANTITY (2) (1) (1) (1) DESCRIPTION Spill Switches with manual reset, 200o F set point Wire routing packet 8" jumper wire 6' 16/2 jacketed cable DIAGRAM A3 INSTALLATION 1. Attach Spill Switches to draft hood (A1), diverter (A2) or barometric control (A3), see respective diagram. [. . . ] Remove vent connector from vent breaching at joint above Spillage Sensing Switches, (See Diagram C1). Block vent connector with sheet metal or other non-combustible material, (See Diagram C2). Adjust thermostat to call for heat allowing burner to fire. RESULT: Spillage will emit from draft hood, diverter or barometric control. In less than two minutes, Spillage Sensing Switches will open, preventing thermostat signal from reaching burner. If Sensing Switches do not open, check for vent pipe leakage. Wait 2-3 Minutes. . . Push reset button on Spillage Sensing Switches. CAUTION: Metal vent pipe will be HOT! 3. 4. DIAGRAM C1 COMBUSTION AIR TEST The 24SP200 Flue Gas Spillage Sensing Kit is designed to alert the user to a potentially hazardous condition. It is not designed to, and cannot replace regular chimney inspection, appliance servicing and combustion testing. DO NOT USE THE 24SP200 AS A SUBSTITUTE FOR PROFESSIONAL APPLIANCE MAINTENANCE. DIAGRAM C2 1. Close all doors and windows of the building. If appliance is installed in utility room or closet, close the entrance door to this room. Turn on all exhaust fans, such as range hoods, bathroom exhausts and whole house fans to maximum speeds. Do not operate a fan used strictly for summer exhausting. [. . . ] Customer Service Department at 1-800-255-4208. 7:30 AM-4:30 PM CST. OWNERS INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT DO NOT DESTROY REV. 1, 3/97 © 1997 TJERNLUND PRODUCTS, INC. P/N 8504056 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND 950-2420 24SP200 SPILLAGE KIT 8504056 REV 1 0397

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND 950-2420 24SP200 SPILLAGE KIT 8504056 REV 1 0397 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag