[. . . ] 45 degree elbows are equivalent to 5 feet of straight duct. The number after the EF-matches the round duct diameter. Example: The EF-6AUTO connects to 6" round duct. For complete dimensions and performance specifications visit www. tjernlund. com. [. . . ] Extreme caution must be exercised to prevent injury. If EF-AUTO fan does not run when the forced air handler fan/blower is running, verify 115 VAC power is supplied to the outlet the EF-AUTO is plugged into. If 115 VAC power is supplied to outlet and EF-AUTO does not run follow the steps below. Block register at end of EF-AUTO duct run and turn on air handler fan/blower. If EF-AUTO turns on with register blocked, verify furnace filter is clean. Replace filter if dirty and see if EF-AUTO turns on when air handler fan/blower is running. If filter is clean, move EF-AUTO closer to the Air handler fan/blower to see if higher pressure turns EF-AUTO on. Proceed to next step if EF-AUTO does not turn on. CAUTION: You will need to check for voltage across PRC control to proceed. Pull motor leads off of M1 & M2 on PRC sensing control. With forced air handler fan/blower running, check for 115 VAC across M1 & M2 on PRC sensing control, (See Diagram C). If voltage is not present, contact Tjernlund Products, Inc. @ 800-255-4208 for further assistance.
FOLLOW THE STEPS BELOW FOR AN EXISTING INSTALLATION:
It may be necessary to measure voltage during troubleshooting. Extreme caution must be exercised to prevent injury. If EF-AUTO fan does not run when the forced air handler fan/blower is running, verify 115 VAC power is supplied to the outlet the EF-AUTO is plugged into. If 115 VAC power is supplied to outlet and EF-AUTO does not run follow the steps below. IMPORTANT: Unplug EF-AUTO fan from outlet before proceeding. Use a small screw driver to carefully pry sensing tube off of PRC sensing port while at the same time pulling on sensing tube, (See Diagram D). [. . . ] EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so that limitation may not apply to you. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND EF-6AUTO
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND EF-6AUTO will begin.