User manual TJERNLUND HS-3C CANADIAN 8504002 REV 2 0997

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND HS-3C CANADIAN 8504002 REV 2 0997. We hope that this TJERNLUND HS-3C CANADIAN 8504002 REV 2 0997 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND HS-3C CANADIAN 8504002 REV 2 0997.


Mode d'emploi TJERNLUND HS-3C CANADIAN 8504002 REV 2 0997
Download
Manual abstract: user guide TJERNLUND HS-3C CANADIAN 8504002 REV 2 0997

Detailed instructions for use are in the User's Guide.

[. . . ] 2 9/97 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODEL HS-3C FOR NATURAL GAS OR LP OWNER INSTRUCTIONS, DO NOT DESTROY !Recognize this symbol as an indication of important Safety Information! NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED 285OC (550 OF) AT VENT SYSTEM INLET. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, PERSONAL INJURY OR PROPERTY DAMAGE. [. . . ] This will diminish the possibility of appliance interruption during periods of extreme winds. CODE REQUIREMENTS · A venting system shall not terminate underneath a veranda, porch, or deck, or above a paved sidewalk or a paved driveway that is located between two buildings, and that serves both buildings. · The exit terminals of mechanical draft systems shall not be less than 2. 13m (7ft) above grade when located adjacent to a paved sidewalk or driveway. · A venting system shall not direct flue gases towards brickwork, siding, or other construction, in such a manner that may cause damage from heat or condensate from the flue gases. · A vent system shall not direct flue gases so as to jeopardize people, overheat combustible structures, or enter buildings. A venting system shall not terminate within 1. 8 m (6ft) of the following: · A window, door or mechanical air supply inlet of any building, including soffit openings · A gas service regulator vent outlet · A combustion air inlet · A property line · A direction facing combustible materials or openings of surrounding buildings A venting system shall not terminate within 1m (3ft) of the following: · Above a gas meter/regulator assembly within 1m (3ft) horizontally of the vertical centreline of the regulator · A oil tank or an oil tankfill inlet · The inside corner of an L-shaped structure A venting system shall not terminate within . 3m (1ft) of the following: · Above grade level or any surface that may support snow, ice, or debris 3 POWER VENTER MOUNTING The installer must supply plumber's strap or 1/4" threaded rod with nuts and washers for mounting. The Power Venter may be mounted in any position as long as the shaft of the motor remains horizontal. The Power Venter housing is single wall, 15. 2 CM (6") must be maintained from all combustible materials. It is recommended that the Power Venter be mounted as close as possible to the point of termination. VENT PIPE INSTALLATION If Installing the Power Venter on an appliance not equipped with a draft hood or draft diverter (e. g. Power Burners, Induced Draft), a barometric draft control must be added. The barometric draft control must be the same size as the flue outlet and installed as close as possible to the appliance. After the draft hood, draft diverter or barometric draft control, a tapered reducer should be installed to reduce the flue to the size shown in the capacity table on page 1 of these instructions. After the tapered reducer, install the appropriate type of vent pipe to the inlet of the Power Venter. The vent pipe chosen must be in compliance with local codes. The Power Venter inlet and outlet are designed to accept single wall vent pipe. If using vent pipe other than single wall, the installer must supply adapters to connect to the Power Venter. While it is recommended that the Power Venter be mounted at the point of termination, it is acceptable to install vent pipe between the outlet of the Power Venter and the point of termination. The Installer must seal all vent pipe connections after the Power Venter with high-temperature caulk or aluminum vent pipe tape to prevent flue gas leakage during operation. The size of the vent pipe between the Power Venter and point of termination should be the same size shown on the selection table. Support the vent pipe as recommended by it's manufacturer. Examples of proper vent pipe installation are shown below. IMPORTANT: Elbows placed directly after discharge on Power Venter may cause erratic operation of Fan Prover. [. . . ] will issue credit to the original distributor or provide a free part to replace one that becomes defective during the one year warranty period. If the part is over 18 months old, proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under one year. All receipts should include the date code of the Power Venter to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND HS-3C CANADIAN 8504002 REV 2 0997

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND HS-3C CANADIAN 8504002 REV 2 0997 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag