User manual TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800. We hope that this TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800.


Mode d'emploi TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800
Download
Manual abstract: user guide TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800

Detailed instructions for use are in the User's Guide.

[. . . ] TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM WARNING: The BLACK & WHITE Power Venter motor wires shown the diagram below are applicable only for the HS115-3. For models HS115-4 & HS115-5 use BLACK and WHITE wires from electrical box wip and connect to proper terminals on motor. Upon first startup, as viewed from opposite end of shaft, verify HS115-4 & HS115-5 motors rotate clockwise. Mount electrical box with Fan Prover in a vertical position. [. . . ] It is recommended that the Power Venter be mounted as close as possible to the point of termination. HS-3 HS-4, HS-5 VENT PIPE INSTALLATION If Installing the Power Venter on an appliance not equipped with a draft hood or draft diverter (e. g. Power Burners, Induced Draft), a barometric draft control must be added. The barometric draft control must be the same size as the flue outlet and installed as close as possible to the appliance. After the draft hood, draft diverter or barometric draft control, a tapered reducer should be installed to reduce the flue to the size shown in the selection table on page 2 of these instructions. After the tapered reducer, install the appropriate type of vent pipe to the inlet of the Power Venter. The vent pipe chosen must be in compliance with local codes. The Power Venter inlet and outlet are designed to accept single wall vent pipe. If using vent pipe other than single wall, the installer must supply adapters to connect to the Power Venter. ELECTRICAL SPECIFICATIONS 5 MODEL HS-3, HS-4, HS-5 WIRING WITH SINGLE APPLIANCE The HS-3, HS-4, and HS-5 Power Venters are equipped with 2 relays. One is used to activate the Power Venter while the other is used to isolate the Fan Proving Switch from the load of the appliance. The relays and Fan Proving Switch are factory wired for easy installation. The installer needs to complete 3 steps to wire the Power Venter as noted below: 1. Route the metal conduit from the electrical box to the Power Venter motor and connect the Black, White and Ground wires to the motor. Connect the Red, Blue and Orange wires in the electrical box to the appliance. Supply 115 VAC to the input wires in the electrical box. NOTE: All models as viewed from the opposite end of the shaft should rotate clockwise. The motor should be wired correctly by Tjernlund for proper rotation. INTERNAL WIRING OF H FACTORY WIRING OF HS-3, HS-4, HS-5 ELECTRICAL BOX LADDER DIAGRAM OF HS-3, HS-4, HS-5 6 MODELS HS-3, HS-4, HS-5 CONNECTION DIAGRAMS WITH SINGLE APPLIANCE The diagrams below represent common ways in which the HS-3, HS-4, HS-5 Power Venters are interlocked to 24V controlled appliances. Variations of these diagrams are acceptable as long as the Fan Proving Switch isolation circuit is wired to disable the gas valve if a venting malfunction should occur. HS-3, HS-4, HS-5 CONNECTED TO APPLIANCE WITH SPARK IGNITION WARNING: The BLACK & WHITE motor wires shown in this diagram are applicable only for the HS-3. For models HS-4 & HS-5 use BLACK and WHITE wires from electrical box wip and connect to proper terminals on motor. See motor nameplate for proper wiring. HS-3, HS-4, HS-5 CONNECTED TO A BOILER WARNING: The BLACK & WHITE motor wires shown in this diagram are applicable only for the HS-3. [. . . ] will issue credit to the original distributor or provide a free part to replace one that becomes defective during the one year warranty period. If the part is over 18 months old, proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under one year. All receipts should include the date code of the Power Venter to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND HS115-3,4,5 (DISCONTINUED) 8505010 REV 0800 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag