User manual TJERNLUND HS3,4,5 POWER VENTERS WITH UC1 CONTROL 8506002 REV B 1002

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND HS3,4,5 POWER VENTERS WITH UC1 CONTROL 8506002 REV B 1002. We hope that this TJERNLUND HS3,4,5 POWER VENTERS WITH UC1 CONTROL 8506002 REV B 1002 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND HS3,4,5 POWER VENTERS WITH UC1 CONTROL 8506002 REV B 1002.


Mode d'emploi TJERNLUND HS3,4,5 POWER VENTERS WITH UC1 CONTROL 8506002 REV B 1002
Download
Manual abstract: user guide TJERNLUND HS3,4,5 POWER VENTERS WITH UC1 CONTROL 8506002 REV B 1002

Detailed instructions for use are in the User's Guide.

[. . . ] HS3 MOTOR SPECIFICATIONS HS-3 MOTOR SPECIFICATIONS ELECTRICAL DATA TJERNLUND PRODUCTS, INC. TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MECHANICAL DATA HS-3 POWER VENTER SPECIFICATIONS HS3 POWER VENTER SPECIFICATIONS HS3 FAN CURVE WITH DAMPER OPEN DESCRIPTION OF APPLICATION Used as a means of Side Wall Venting commercial gas appliances. [. . . ] @ 120 VAC. UC1 UNIVERSAL CONTROL COMPONENT DESCRIPTION HS3 REV B 10/02 HS4 MOTOR SPECIFICATIONS HS-4 MOTOR SPECIFICATIONS ELECTRICAL DATA TJERNLUND PRODUCTS, INC. TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com DESCRIPTION OF APPLICATION Used as a means of Side APPLICATION DESCRIPTION OF Wall Venting commercial gas appliances. Used also to co-vent multiple heaters within combined BTU/hr. input listed below (requires accessory controls). Includes a Fan Proving Switch and the UC1 Universal Control for 24V, 115V or "dry contact" actuation. LED diagnostics and Pre / Post-purge options are standard with the UC1. HS-4 (Discontinued 7/02) Replace with model HS4. HS-4 POWER VENTER SPECIFICATIONS HS4 POWER VENTER SPECIFICATIONS MECHANICAL DATA HS4 FAN CURVE WITH DAMPER OPEN Note: Tjernlund Products, Inc. reserves the right to make changes to specifications without notification. HS4 Maximum Power Consumption 1/2 Amp @ 120 VAC 50/60 Hz + Venter motor load Pre-Purge: Options (0, 15, 30, 60 seconds) Post-Purge: Factory set at 2 minutes Options (0, 30 seconds; 1, 2, 4, 8, 16 minutes) Dimensions: 5" x 8" (2' electrical whip inc. ) FAN PROVING SWITCH 5 VDC UC1 board supplied power switched through Fan Prover. UC1 burner / gas valve interlock rated for 1 H. P. @ 120 VAC. COMPONENT DESCRIPTION UC1 UNIVERSAL CONTROL HS5 MOTOR SPECIFICATIONS HS-5 MOTOR SPECIFICATIONS ELECTRICAL DATA TJERNLUND PRODUCTS, INC. TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com DESCRIPTION OF APPLICATION Used as a means of Side Wall Venting commercial gas appliances. Used also to co-vent multiple heaters within combined BTU/hr. [. . . ] @ 120 VAC. 208-230 VAC motor wiring is not compatible with the UC1 Control. A 115 VAC coil / 230 VAC contact DPST motor contactor rated for 1 H. P. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND HS3,4,5 POWER VENTERS WITH UC1 CONTROL 8506002 REV B 1002

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND HS3,4,5 POWER VENTERS WITH UC1 CONTROL 8506002 REV B 1002 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag