User manual TJERNLUND HSUL,HST,HS115-J,1,2 POWER VENTERS (DISCONTINUED) 8506001 REV 1 1194

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND HSUL,HST,HS115-J,1,2 POWER VENTERS (DISCONTINUED) 8506001 REV 1 1194. We hope that this TJERNLUND HSUL,HST,HS115-J,1,2 POWER VENTERS (DISCONTINUED) 8506001 REV 1 1194 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND HSUL,HST,HS115-J,1,2 POWER VENTERS (DISCONTINUED) 8506001 REV 1 1194.


Mode d'emploi TJERNLUND HSUL,HST,HS115-J,1,2 POWER VENTERS (DISCONTINUED) 8506001 REV 1 1194
Download
Manual abstract: user guide TJERNLUND HSUL,HST,HS115-J,1,2 POWER VENTERS (DISCONTINUED) 8506001 REV 1 1194

Detailed instructions for use are in the User's Guide.

[. . . ] MOTOR SPECIFICATIONS ELECTRICAL DATA Volts 115 Hertz 60 RPM 3000 Watts 95 Amps 1. 26 Therm. Yes MECHANICAL DATA DESCRIPTION Shaded Pole Open Int. [. . . ] NOTE: TO ARRIVE AT TOTAL SYSTEM STATIC PRESSURE REFER TO CURVE AND ADD . 38" TO COMPENSATE FOR VENT HOOD AND WIND RESISTANCE. COMPONENT DESCRIPTION Relay (Model HSUL-J only) 24/115V Switching Relay Timer Relay (Model HST-J only) Dual Voltage 24/115V input, 1-10 minute post purge adjustment Fan Proving Switch (All Models) 3 FLA, 18LRA @ 120V P/N 8506001 REV. 1 11/94 -SIDE VIEW- -END VIEW- -PLAN VIEW- MOTOR SPECIFICATIONS ELECTRICAL DATA Volts 115 Hertz 60 RPM 3000 Watts 166 Amps 1. 51 Therm. Yes MECHANICAL DATA DESCRIPTION Shaded Pole Open Int. Length (In) BEARINGS Type Material Yes Yes Yes 3. 33 4. 50 . 313 2. 25 Sleeve Sintered Iron TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODELS AND APPLICATION: HSUL-1 (Gas) Used as a means of Side Wall Venting 24 volt controlled appliances. This Power Venter includes a 24/115 volt switching Relay and a Fan Proving Switch. HS115-1 (Gas) Used as a means of Side Wall venting 115 volt appliances. This Power Venter DOES NOT include a Switching Relay but still includes the Fan Proving Switch. HST-1 (Oil or Gas) Used as a means of Side Wall Venting 24 volt or 115 volt controlled appliances which require a Post Purge cycle. This Power Venter includes a Post Purge Timer Relay and a Fan Proving Switch. reserves the right to make changes to specifications without notification. HSUL-1, HS115-1 & HST-1 POWER VENTER SPECIFICATIONS Performance curves Static pressure (inches H2O) vs CFM (std. NOTE: TO ARRIVE AT TOTAL SYSTEM STATIC PRESSURE REFER TO CURVE AND ADD . 38" TO COMPENSATE FOR VENT HOOD AND WIND RESISTANCE. COMPONENT DESCRIPTION Relay (Model HSUL-1 only) 24/115V Switching Relay Timer Relay (Model HST-1 only) Dual Voltage 24/115V input, 1-10 minute post purge adjustment Fan Proving Switch (All Models) 3 FLA, 18LRA @ 120V -SIDE VIEW- -END VIEW- -PLAN VIEW- MOTOR SPECIFICATIONS ELECTRICAL DATA Volts 115 Hertz 60 RPM 3300 Watts 166 Amps 1. 51 Therm. Length (In) BEARINGS Type Material Yes Yes No 3. 33 4. 50 . 313 2. 25 Sleeve Sintered Iron TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODELS AND APPLICATION: HSUL-2 (Gas) Used as a means of Side Wall Venting 24 volt controlled appliances. [. . . ] reserves the right to make changes to specifications without notification. HSUL-2, HS115-2 & HST-2 POWER VENTER SPECIFICATIONS Performance curves Static pressure (inches H2O) vs CFM (std. NOTE: TO ARRIVE AT TOTAL SYSTEM STATIC PRESSURE REFER TO CURVE AND ADD . 38" TO COMPENSATE FOR VENT HOOD AND WIND RESISTANCE. COMPONENT DESCRIPTION Relay (Model HSUL-1 only) 24/115V Switching Relay Timer Relay (Model HST-1 only) Dual Voltage 24/115V input, 1-10 minute post purge adjustable Fan Proving Switch (All Models) 3 FLA, 18LRA @ 120V -SIDE VIEW-END VIEW-PLAN VIEW- [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND HSUL,HST,HS115-J,1,2 POWER VENTERS (DISCONTINUED) 8506001 REV 1 1194

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND HSUL,HST,HS115-J,1,2 POWER VENTERS (DISCONTINUED) 8506001 REV 1 1194 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag