User manual TJERNLUND MAC1E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 1105

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND MAC1E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 1105. We hope that this TJERNLUND MAC1E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 1105 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND MAC1E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 1105.


Mode d'emploi TJERNLUND MAC1E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 1105
Download
Manual abstract: user guide TJERNLUND MAC1E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 1105

Detailed instructions for use are in the User's Guide.

[. . . ] LED #1 (Amber) shows an appliance call for heat. LED #2 (Blue) shows that the burner is approved to fire after the Venter Fan Prover safety circuit through the UC1 is completed. LED #6 (RED) means power is supplied to the MAC1E through the UC1. MILLIVOLT INSTALLATIONS Each millivolt appliance interlocked with the MAC1E must have its own WHKE kit installed. [. . . ] MAC1E SAFETY INTERLOCK TEST PERFORM THE FOLLOWING INTERLOCK TEST AFTER CONNECTING MAC1E TO UC1 AND INTERLOCKING ALL BURNERS 1. Confirm power is supplied to MAC1E control from the UC1. MAC1E LED #1 (AMBER) should be on indicating an appliance call for heat. If the UC1, P1 & P2 Prover safety circuit is closed, indicating an approved condition, the appliance interlock relay will close making terminal #3 closed to terminal #4. MAC1E LED #2 (BLUE) shows that the burner is approved to fire. Fire all appliances to make sure each burner fires properly. Remove power to the UC1 and any interlocked appliances. The Power LED (RED) on UC1 or any LED's on UC1 or MAC1E should not be on. Test the safety circuit by removing either lead from Fan Prover switch connected to UC1 P1 and P2 Fan Prover safety circuit. Do not let the opened LEAD touch a ground or damage may occur to the control when power is reestablished. Reestablish power to the UC1 and interlocked appliances and initiate a call for heat. After 60 seconds a Prover Start Up fault should arise with UC1 LED #4 flashing 3 times. Remove appliance call for heat and power to the UC1 and any interlocked appliances. The Power LED (RED) on UC1 or any LED's on UC1 or MAC1E should not be on. Reconnect Fan Prover switch lead removed in step 4. Reestablish power to UC1 and interlocked appliances and initiate a call for heat from each appliance to confirm proper operation of UC1, MAC1E and appliances. Perform Draft Adjustment and Combustion air safety check as outlined in Venter/Inducer installation manual. IMPORTANT: DO NOT OPERATE AN APPLIANCE THAT OPERATES WITH THE PROVER SAFETY CIRCUIT DISCONNECTED!RESETTING FAULT CODE CREATED BY STEP 4 OF SAFETY INTERLOCK TEST IMPORTANT: Prior to accessing the fault code memory, note the settings of the UC1 dip switches so that they can be returned to their original Pre / Post-Purge positions. When power is supplied to the UC1 use caution when moving dip switches. The last fault code can be retrieved at any time by setting all dip switches 1-8 to the up, or "on" position. [. . . ] USER-PROVIDED CALL SWITCH "DRY" OR LINE / HOT COMMON / NEUTRAL J2 J1 XL XN R DO NOT SUPPLY VOLTAGE TO "A" OR "B". IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. LED2 LED1 LED6 IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. LED5 LED4 LED3 LED2 LED1 LED6 USER-PROVIDED CALL SWITCH DRY 24V RED POWER LED BLUE AMBER DRY 24V 115V 115V P2 RED POWER LED BLUE RED RED GREEN AMBER "DRY" CALL JUMPER OR LINE / HOT C INTERCEPTED CALL FOR HEAT J2 CALL JUMPER COM PROVER P1 ON PRE-PURGE SETTINGS (1 - 2) POST-PURGE SETTINGS (3 - 8) NO COM C INTERCEPTED CALL FOR HEAT GND APPLIANCE "GO" APPLIANCE CALL NO COMMON / NEUTRAL INTERLOCK RELAY F APPROVED SUPPLY 115 VAC 50/60 Hz K1 J1 GND 123456789 APPROVED XL INTERLOCK RELAY K1 F XN OPEN PROVER OPTION (9) R K2 N V I O GL RE AT RY E D V I O GL RE A RYT E D M TJERNLUND PRODUCTS, INC. TJERNLUND PRODUCTS, INC. VENTER / INDUCER MOTOR 1 H. P. MAX @ 115 VAC W H I T E G R E E N 24" FLEX CONDUIT G R E E N B L A C K W H I T E MTR B L A C K MAC1E CONTROL UNIVERSAL CONTROL P/N 1303962A IMPORTANT: Venter Fan Prover must be wired to P1 and P2 safety circuit in UC1. RED appliance interlock voltage jumper in MAC1E and UC1 must be positioned based on the control voltage of the appliance interlocked with each control 115V, 24V or DRY. Connect Black from MAC1E whip to XL on UC1. Connect White from MAC1E whip to XN on UC1. Connect Violet from MAC1E whip to C on UC1 Connect Gray from MAC1E whip to GND on UC1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND MAC1E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 1105

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND MAC1E CONTROL VERSION F (COMPATIBLE WITH UC1 CONTROL) 8504112 REV B 1105 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag