User manual TJERNLUND SIDESHOT OIL & GAS SIDE WALL VENT SYSTEMS 8500000 REV. B 0404

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND SIDESHOT OIL & GAS SIDE WALL VENT SYSTEMS 8500000 REV. B 0404. We hope that this TJERNLUND SIDESHOT OIL & GAS SIDE WALL VENT SYSTEMS 8500000 REV. B 0404 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND SIDESHOT OIL & GAS SIDE WALL VENT SYSTEMS 8500000 REV. B 0404.


Mode d'emploi TJERNLUND SIDESHOT OIL & GAS SIDE WALL VENT SYSTEMS 8500000 REV. B 0404
Download
Manual abstract: user guide TJERNLUND SIDESHOT OIL & GAS SIDE WALL VENT SYSTEMS 8500000 REV. B 0404

Detailed instructions for use are in the User's Guide.

[. . . ] Also, eliminating chase increases living space and affords greater interior layout flexibility. Easy, One-Person Installation There's no pre-installation assembly required. Units attach to all classes of standard vent pipe. To reduce weight during installation and maximize serviceability, mechanical and electrical assemblies are located on the back of the unit and attached after vent termination is installed. Cut Opening Install Vent Termination Featuring UC1 Burner Interlock Control s Simplifies new installations and service calls since operation and wiring interlock problems are diagnosed and displayed through LED indicators. [. . . ] It automatically vents the flue gases from heating equipment to the outdoors. Surrounding combustible surfaces and exhaust gases are kept at safe temperatures by pulling outdoor air into its casing and mixing it with the flue gases during operation. After each burner cycle the SS1 will continue to operate for an adjustable period to purge the heater and vent of residual gases. The SS1 features a 3-way safety system consisting of the UC1 Interlock Control, Fan Proving Switch and High Limit. These devices monitor the SS1 performance and will disrupt the burner if a vent system malfunction is detected. Electrical Typical Burner Interlock with Aquastat Adjustable draft control Stainless Steel vent hood Flue gases Factory-wired controls SideShot 1 Application Tables Verify that the total BTU/hr. input of the heating appliance(s) fall within the proper category listed below. Please note the maximum equivalent feet and capacity differs between the SS1 and SS1C. To determine equivalent feet, add the total length of straight vent pipe plus 10 feet for each 90 degree elbow and 5 feet for each 45 degree elbow. Vent runs of over 15 linear feet should use an approved, insulated vent connector to prevent problems related to sulfur condensation. Note: The SS1 features a bottom or rear vent connection. The inlet collar accepts any brand or type of 6" diameter vent pipe. Power Requirement: Maximum of 2. 8 amps Motor HP: 1/10 Pre-purge: Options (0, 5, 20, 35 seconds) Post-Purge: Factory set at 2 minutes, Options (0, 30 seconds or 1, 2, 4, 8, 16 minutes) Dimensions A B C D E F G H I 27-3/8'' 16-1/2'' 12-1/4'' 8'' 13-3/4'' 15-1/8'' 7-3/4'' 14-3/4'' 23-1/4'' MODEL Natural LP Gas Flame Retention Oil Burner Standard Oil Burner Max. Equivalent Feet SS1 50, 000 - 160, 000 70, 000 - 220, 000* 70, 000 - 180, 000* BTU/hr. BTU/hr BTU/hr. 50 SS1C For Capacities Up To 315, 000 BTU/hr. MODEL Natural LP Gas NA Flame Retention Oil Burner Standard Oil Burner Max. Equivalent Feet SS1C 50, 000 - 315, 000* 50, 000 - 223, 000* BTU/hr. BTU/hr 50 FRONT VIEW SIDE VIEW *Calculate BTU/hr. input based on nozzle size and actual pump pressure. Note: The SS1 requires an 8"H x 8 3/8"W opening through the wall. Whisper quiet, 2nd generation vent system Indoor Draft Adjustment Precise draft is achieved by simply turning knob located on back of unit. No Annual Maintenance Self-cleaning stainless steel impeller and sealed ball bearing motor make the SS2 virtually maintenance free. Backward inclined impeller blades resist soot build up, reducing vibration and noise problems. Cooling fan forces room air directly over motor to extend its life. An Inside Look At The SS2 System Outside air cools gases Circulating room air keeps housing cool The SS2's innovative design is the result of an extensive research and development program involving heating contractors and end users. Due to its simplicity and practical built-in features, the SS2 takes side wall venting to a higher level of installation and maintenance convenience, operating and energy-saving efficiency -- at a very affordable price. Room air enters SS2 Cooled gases propelled from SS2 Warmed room air returns to room Hot flue gas from heating appliance General Description The SS2 is a mechanical vent system designed and listed for use with natural draft oil and gas heating equipment. [. . . ] input based on nozzle size and actual pump pressure. Maximum capacity based on 13% CO2 and Max. 5000 F inlet temperature. Dimensions A B C D E F G H I J 32-1/2'' 28-1/2'' 5-1/2'' 22-3/8'' 7-3/4'' 8'' 12-1/2'' 13-1/4'' 10-1/2'' 8-1/2 Electrical Power Requirement: Maximum of 2. 3 amps Motor HP: 1/20 Pre-Purge: Options (0, 5, 20, 35 seconds) Post-Purge: Factory set at 2 minutes, Options (0, 30 seconds, 1, 2, 4, 8, 16 minutes) Typical Burner Interlock with 24V Thermostat FRONT VIEW SIDE VIEW BACK VIEW Note: SS2 has a 4" vent connector. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SIDESHOT OIL & GAS SIDE WALL VENT SYSTEMS 8500000 REV. B 0404

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SIDESHOT OIL & GAS SIDE WALL VENT SYSTEMS 8500000 REV. B 0404 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag