User manual TJERNLUND SS2 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504063 REV B 1199

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND SS2 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504063 REV B 1199. We hope that this TJERNLUND SS2 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504063 REV B 1199 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND SS2 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504063 REV B 1199.


Mode d'emploi TJERNLUND SS2 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504063 REV B 1199
Download
Manual abstract: user guide TJERNLUND SS2 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504063 REV B 1199

Detailed instructions for use are in the User's Guide.

[. . . ] B 11/99 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (651) 426-2993 · (800) 255-4208 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODEL SS2 INSTALLATION INSTRUCTIONS !Recognize this symbol as an indication of important safety information! OWNER INSTRUCTIONS, DO NOT DESTROY !CAUTION: The owner of the SS2 must keep the area around the vent terminal free of snow, ice and debris. NOTE: MAXIMUM FLUE GAS TEMPERATURES MUST NOT EXCEED 650oF (343O C) MINIMUM TEMPERATURE MUST BE 250O F (121O C) AT VENT SYSTEM INLET. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. [. . . ] Turning this draft adjustment knob clockwise will increase draft and raise the BTU capacity. Turning the knob counter-clockwise will decrease draft and lower the BTU capacity. The SS2 is factory set for the highest draft (BTU capacity). IMPORTANT: Before proceeding, close all windows, doors and fireplace dampers. Turn on all appliances in the structure that exhaust indoor air such as clothes dryer, exhaust fans, range hoods, bathroom and whole house exhaust fans. Failure to perform the draft adjustment procedure may cause a poor vent system installation possibly resulting in fire, carbon monoxide poisoning, explosion, personal injury or property damage. Insert a stack thermometer into the vent pipe as close as possible to the SS2 inlet. NOTE: plug hole when finished with installation. Adjust barometric draft control to the minimum or least draft setting. Place the heating system into operation. NOTE: There will be a slight pause between the venter operation and the burner operation. Continuously monitor the over fire draft and adjust the SS2 draft adjustment knob to maintain a reading of -. 02 to -. 03" W. C. . When the flue gas temperature at the venter inlet has stabilized make any final draft adjustment necessary to maintain a reading of -. 02 to -. 03" W. C. . IMPORTANT: If a minimum of -. 02" W. C. cannot be obtained with the SS2 draft adjustment knob turned fully clockwise, close the burner air shutter until a reading of -. 02" W. C. Perform a smoke test and make any adjustments to the burner air shutter and venter draft adjustment to arrive at a trace of smoke (between 0 and 1) at a minimum over fire draft of -. 02" W. C. . Perform a CO2 test at the same location as the smoke test. Reduce the CO2 1% to 2% by opening the burner air shutter. Recheck over fire draft and increase venter draft if necessary to maintain a minimum of -. 02" W. C. . IMPORTANT: Depending on installation variables it may be necessary to operate burner at CO2 levels of 12% to 13% with firing rates over 1 GPH to maintain a minimum of -. 02" W. C. Consult factory at 1-800-255-4208 if you experience burner setup problems. Do not allow heating system to run at less than a -. 02" W. C. over fire draft or at a CO2 level that is less than a 1% reduction from the value measured at a trace of smoke and a -. 02" W. C. [. . . ] will issue credit or provide a free part to replace one that becomes defective during the two year warranty period. If the part is over 30 months old, proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under two years. All receipts should include the date code of the SideShot to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SS2 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504063 REV B 1199

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SS2 SIDESHOT (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504063 REV B 1199 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag