User manual TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504105 REV B 0503
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504105 REV B 0503. We hope that this TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504105 REV B 0503 user guide will be useful to you.
Lastmanuals help download the user guide TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504105 REV B 0503.
Manual abstract: user guide TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504105 REV B 0503
Detailed instructions for use are in the User's Guide.
[. . . ] B 05/03
TJERNLUND PRODUCTS, INC.
1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (651) 426-2993 · (800) 255-4208 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com
VERSION X. 04
INCLUDES NEW UC1 UNIVERSAL CONTROL
MODEL SS2 INSTALLATION INSTRUCTIONS
!Recognize this symbol as an indication of important safety information!
OWNER INSTRUCTIONS, DO NOT DESTROY
!CAUTION: The owner of the SS2 must keep the area around the vent terminal free of snow, ice and debris.
NOTE: MAXIMUM FLUE GAS TEMPERATURES MUST NOT EXCEED 650oF (343O C) MINIMUM TEMPERATURE MUST BE 250O F (121O C) AT VENT SYSTEM INLET.
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. [. . . ] Crimp Ground wire to grounding spade in SS2 electrical box. Make sure RED voltage jumper on UC1 is on DRY. NOTE: If burner safety control goes out on lockout, the SideShot will continue to run as long as a call for heat is present.
SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH A HONEYWELL R8184 SERIES OR EQUIVALENT PRIMARY CONTROL AND A BURNER MOTOR POST-PURGE
L1 THERMOSTAT BLACK ORANGE WHITE B O W T T F 115V DRY 24V F HONEYWELL R8184 SERIES OR EQUIVALENT J2 J1
UNIVERSAL CONTROLLER
IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE.
CALL JUMPER
OIL VALVE SUPPLY 115 VAC 50/60 Hz
R
XL XN N M MTR
9183006 TJERNLUND PRODUCTS, INC.
LEGEND: 115 VAC
D/N 9183046-4
BURNER MOTOR
IGNITION TRANS
SS2 MOTOR
SS2 COOLING FAN
IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN SS2 ELECTRICAL BOX.
1. Separate the burner motor wire and ignition transformer from the Orange wire of R8184. Connect the Orange of R8184 to #1 on UC1 terminal block. Connect #2 on UC1 terminal block to White on R8184 or N. Connect the HOT wire of oil solenoid valve to #4 on UC1 terminal block and neutral wire to White or N. Connect burner motor and ignition transformer HOT wires to M terminal on UC1 and neutrals to White or N. Connect 115 VAC supply voltage to L & N terminals on UC1. Installer must supply overload and disconnect protection. Crimp ground wire to grounding spade in SS2 electrical box. Make sure RED voltage jumper on UC1 is on 115V. 13
SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH A SINGLE ZONE 24 VAC THERMOSTAT
IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE.
THERMOSTAT
Y R G R C J1 Y W INTERNAL CONTROL OF FURNACE SUPPLY 115 VAC 50/60 Hz
R
115V
DRY
24V
W G J2 XL XN
UNIVERSAL CONTROLLER
CALL JUMPER
LEGEND: 115 VAC 24 VAC
D/N 9183046-5
IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN SS2 ELECTRICAL BOX.
1. Connect W from t-stat to #1 on terminal block of UC1. Connect #2 on UC1 terminal block to C on internal control terminal strip of furnace/boiler. Connect #4 on UC1 terminal block to W on internal control terminal strip of furnace/boiler. Connect 115 VAC supply voltage to L & N terminals on UC1. Installer must supply overload and disconnect protection. Crimp ground wire to grounding spade in SS2 electrical box. Make sure RED voltage jumper on UC1 is on 24V. NOTE: If burner safety control goes out on lockout, the SideShot will continue to run as long as a call for heat is present.
SIDESHOT WITH INTEGRAL UC1 CONTROL CONNECTED WITH A 24 VAC ELECTRONIC IGNITION MODULE
IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. SPARK (9) (8) J2
OR
115V
UNIVERSAL CONTROLLER
DRY
CALL JUMPER
24V
J1
(7) 24V 24V GND BNR GND PV MV / PV MV (6) (5) (4) (3) (2) (1)
PI YE
GR YE WH OR WH OR YE
SUPPLY 115 VAC 50/60 Hz
R
XL XN
LEGEND: 115 VAC 24 VAC
D/N 9183046-8
PV PV MV MV
HONEYWELL IGNITION CONTROL
GR
IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN SS2 ELECTRICAL BOX.
GAS VALVE
1. [. . . ] Proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under two years. All receipts should include the date code of the SideShot to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. 1. ) Follow troubleshooting guide to determine defective component. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504105 REV B 0503
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SS2 SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504105 REV B 0503 will begin.