User manual TJERNLUND UC1 UNIVERSAL CONTROL (VERSION X.04) 8504107 REV C 0204

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TJERNLUND UC1 UNIVERSAL CONTROL (VERSION X.04) 8504107 REV C 0204. We hope that this TJERNLUND UC1 UNIVERSAL CONTROL (VERSION X.04) 8504107 REV C 0204 user guide will be useful to you.

Lastmanuals help download the user guide TJERNLUND UC1 UNIVERSAL CONTROL (VERSION X.04) 8504107 REV C 0204.


Mode d'emploi TJERNLUND UC1 UNIVERSAL CONTROL (VERSION X.04) 8504107 REV C 0204
Download
Manual abstract: user guide TJERNLUND UC1 UNIVERSAL CONTROL (VERSION X.04) 8504107 REV C 0204

Detailed instructions for use are in the User's Guide.

[. . . ] C 02/04 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com VERSION X. 04 MODEL UC1 INSTALLATION INSTRUCTIONS !Recognize this symbol as an indication of important Safety Information! OWNER INSTRUCTIONS, DO NOT DESTROY THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS PRODUCT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL INJURY OR PROPERTY DAMAGE. DO NOT DESTROY. [. . . ] Prover Leads are not polarity sensitive. If using a Draft Inducer and only venting millivolt appliances the PS1505 Fan Proving Switch is not necessary, see WHKE instructions for complete details. UC1 UNIVERSAL CONTROL CONNECTED TO A GAS OR OIL BURNER WITH AN AQUASTAT IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. LEGEND: 115 VAC D/N 9183046-7 AQUASTAT L1 L2 C1 C2 B1 B2 115V DRY CALL JUMPER J2 UNIVERSAL CONTROLLER 24V N J1 L1 LINE VOLTAGE OIL BURNER PRIMARY CONTROL, BURNER RELAY OR GAS VALVE SUPPLY 115 VAC 50/60 Hz R XL XN GROUND IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. 1. Disconnect B1 from L1 of oil burner primary control, burner relay or hot of gas valve and reconnect to #1 on UC1 terminal block. Connect #2 on UC1 terminal block to B2 or N. Connect #4 on UC1 terminal block to the L1 on line voltage oil burner primary control, burner relay or gas valve. Make sure RED voltage jumper on UC1 is on 115V. Connect 115 VAC supply voltage to L & N terminals on UC1. Crimp Ground wire to grounding spade terminal in UC1. Important: Installer must supply overload and disconnect protection. If not previously completed, connect ground from UC1 whip to Venter ground. Connect Black and White leads from UC1 whip to Venter motor leads. Connect Blue and Yellow leads from UC1 whip to Fan Prover switch. Prover Leads are not polarity sensitive. NOTE: If burner safety control goes out on lockout, the Venter will continue to run as long as a call for heat is present. 8 UC1 UNIVERSAL CONTROL CONNECTED TO A HONEYWELL R7184 SERIES OR EQUIVALENT PRIMARY CONTROL WITH A LINE VOLTAGE THERMOSTAT OR AQUASTAT R7184 T Low Voltage Jumper T L1 Limit L2 Line Voltage Thermostat or Aquastat Control Limit SUPPLY 115 VAC 60 Hz LEGEND: 115 VAC D/N 9183046-6 IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. Oil Valve OIL VALVE 115V DRY 24V Burner Motor BURNER MOTOR J2 CALL JUMPER UNIVERSAL CONTROLLER Interrupted Ignitor A Alarm A Cad Cell Intermittant IGNITION TRANS J1 SUPPLY 115 VAC 50/60 Hz R XL XN GROUND IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. 1. Disconnect burner motor wire off the R7184. Connect burner motor terminal of R7184 to #1 on UC1 terminal block. Connect #2 on UC1 terminal block to L2 or N. Connect #4 on UC1 terminal block to burner motor wire removed from R7184. Make sure RED voltage jumper on UC1 is on 115V. [. . . ] Proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under one year. All receipts should include the date code of the UC1 to ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal. 1. ) Follow troubleshooting guide to determine defective component. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND UC1 UNIVERSAL CONTROL (VERSION X.04) 8504107 REV C 0204

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND UC1 UNIVERSAL CONTROL (VERSION X.04) 8504107 REV C 0204 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag