If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TL AUDIO IVORY 2 5052. We hope that this TL AUDIO IVORY 2 5052 user guide will be useful to you.
Lastmanuals help download the user guide TL AUDIO IVORY 2 5052.
Detailed instructions for use are in the User's Guide.
[. . . ] TLAudio user manual
®
Ivory 2 Series
5052
STEREO VALVE PROCESSOR
TL Audio Ltd, Letchworth, Herts, SG6 1AN, UK email: info@tlaudio. co. uk web: http://www. tlaudio. co. uk
4. 11
What Is Compression?Overview of Compressor Threshold Ratio Attack and Release Knee Gain Make Up Compressor On EQ S/C & Frequency Conscious Meter Equalisation Cut/Boost Control Frequency Control Q (Bandwidth) Control Shelving EQ EQ On EQ Pre Output Limiter Stereo Link Modes Optional DO-2 Digital
CONTENTS
1 2 3 3. 1 3. 2 3. 3 3. 4 3. 5 3. 6 3. 7 3. 8 3. 9 3. 10 3. 11 4 4. 1 4. 2 4. 3 4. 4 4. 5 4. 6 4. 7 4. 8 4. 9 4. 10 INTRODUCTION PRECAUTIONS INSTALLATION A. C. Mains Supply Microphone Input Compression Balanced Line Input Unbalanced Line Input Instrument Input Insert Points Sidechain Insert Points Line Outputs Nominal Operating Level Ventilation Rear Panel OPERATION Input Stage Microphone Input Line Input Instrument Input 30dB Pad Switch 90Hz Filter Phase Reverse Drive and Peak LEDs Output Gain Bypass
4. 12 4. 13 4. 14 4. 15 4. 16 4. 17 4. 18 4. 19 4. 20 4. 21 4. 22 4. 23 4. 24 4. 25 4. 26 4. 27 4. 28 4. 29 4. 30 4. 31
Operation
Output Card 5 5. 1 5. 2 mode 5. 3 mode 6 7 8 FAQ SPECIFICATIONS SERVICE In Use Stereo mixdown GETTING STARTED Connections In Use Mono tracking
1.
INTRODUCTION
Congratulations on purchasing the Ivory 5052 Stereo Valve Processor by TL Audio!The Ivory 2 Series consists of a range of hybrid valve signal processors, which utilise low noise solid state electronics in conjunction with classic valve circuitry to produce audio processing units offering very high quality signal paths with the unique valve audio character. [. . . ] Working this way frees up the EQ section within the 5052, allowing it to be used for normal EQ duties. 4. 21 Meter.
The 5052 is equipped with a pair of illuminated VU meters. The associated Meter switch enables this meter to monitor each one of four parameters. When switched to `I/P', the meter reads the audio input level just after the preamp stage. When switched to `O/P' the meter reads the audio output level, and is calibrated to read 0VU when a +4dBu signal is reached at the main XLR line outputs of the 5052 (or 10dBu at the unbalanced line outputs). The meter when switched to `Comp G/R' (Gain Reduction) indicates the amount of compression occurring. If the signal is below the threshold, the meter will indicate 0dB: i. e. As the signal passes through the threshold, the meter will start to indicate the gain reduction at the compressor stage (this will be a negative value, so the meter will move to the left, applied. The final setting on the Meter switch is marked `Lim G/R', and this separately monitors the amount of gain reduction that the limiter circuit is applying. A separate `+ 10dB' switch is provided which reduces the meter reading by 10dB below the actual audio signal level, and this applies to both input and output level metering. This is useful when the 5052 is being fed with large input levels - or is producing large output levels - and the meter needle would otherwise be pressing constantly at its end stop. This situation is normal, particularly if the 5052 is interfacing with digital recorders or mixers where large signal levels are regularly encountered. Note that this reading won't include any extra gain make-up
The 5052 equaliser section has four bands, each with continuously variable cut/boost and frequency controls. The LM and HM bands also have a variable Q (or bandwidth) control that means these two bands are fully parametric in operation (see section 4. 25). Before switching the EQ into circuit, it is advisable to set the cut/boost controls to their centre, or flat, position. Each channel of EQ is brought into circuit with the overall "EQ-ON" push switch positioned to the far right of the unit. "EQ-ON" is signalled by a green LED. The four bands of EQ per channel are labelled as LF (low frequency), LM and HM (low and high mid frequency) and HF (high frequency). However, the frequency variation available on each band allows overlapping of two, or more, bands into the same frequency range. This arrangement allows maximum flexibility, permitting
reduction of a narrow band whilst simultaneously boosting an overlapping broader band of frequencies, for example. Used individually or in combination, the filter bands allow comprehensive equalisation of any audio signal. 4. 23 Cut/Boost Control.
Each of the four EQ bands has a +/- 15dB gain control that is used to apply cut or boost at the frequency selected by the Frequency control. [. . . ] Unbalanced output via jack, -10dBu nominal level. Stereo Operation: Independent selection of Compressor, Equaliser and Limiter for stereo. All selected controls stereo ganged, Channel 1 operates as master.
Metering: Variable intensity "Drive" LED, illuminating over the range +6 to +16dBu. "Peak" LED at +19dBu, monitoring the signal chain at multiple points. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TL AUDIO IVORY 2 5052
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TL AUDIO IVORY 2 5052 will begin.