Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA 1700. We hope that this TOSHIBA 1700 user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA 1700.
Detailed instructions for use are in the User's Guide.
[. . . ] UNINTERRUPTIBLE POWER SUPPLIES
1700 Series
User Manual 1700 Series Uninterruptible Power System Single Phase 1. 5/2. 0/2. 4 kVA
IMPORTANT NOTICE The instructions contained in this manual are not intended to cover all of the details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred to the local Toshiba sales office. The contents of this instruction manual shall not become a part of or modify any prior or existing agreement, commitment, or relationship. The sales contract contains the entire obligation of Toshiba International Corporation's UPS Division. [. . . ] Pressing it again will change it back to disabled and the 100% LED will go off. B. 2 Once the option is set as desired, press and hold the function control button to save the setting. The UPS will indicate the setting has been saved by blinking the LED(s). The LED(s) will continue to blink for a short time after which the UPS will exit programming mode and return to bypass operation. To return the system to normal operation switch the RUN/STOP switch back to the RUN position. This should be done whenever a new battery pack is installed. The unit is now ready to reset the battery installed date. This is indicated by the Battery LED turning on. Once this mode has been entered press and hold the function control button to reset the battery install date to the current date. The UPS will indicate that the date has been reset by blinking the Battery LED for a short time after which the UPS will return to bypass operation. To return the system to normal operation switch the RUN/STOP switch back to the RUN position.
Fixed Frequency Mode The 1700 Series UPS has the option of operating in a fixed frequency mode. Normally the UPS operates in the frequency autodetect mode. If a specific output frequency is required (i. e. 50Hz or 60Hz) the UPS can be set at the factory to supply the desired frequency regardless of the input frequency (input frequency must be within allowable limits, see Specifications on page 31). For a unit already in use the output frequency can be set through software. For instructions on setting the output frequency through software please contact Toshiba at (800) 231-1412 or by e-mail at toshibaups@tic. toshiba. com. It is important to note that when the UPS is operating with a fixed output frequency, output is disabled in bypass. Adding an Additional Battery Module Note: Only one additional battery module may be added to the standard unit. For longer runtime options contact your Toshiba sales representative or the Toshiba marketing department at (800) 2311412 or by e-mail at toshibaups@tic. toshiba. com. Figure 5 shows the standard unit with one additional battery module added. To install a second battery module follow these steps: 1) Unplug the standard battery module from the electronics module. Unlock and remove the electronics module from the battery module. [. . . ] Toshiba UPS Unit Battery 1 2 1 2 Series Capacity Dispatch Warranty On-Site Warranty On-Site am pm 1700 1. 5, 2. 0, 2. 4 kVA 36 months No, Depot 24 months No, Depot M-F, 8 -5 CT
Note 1: Note 2: The warranty period begins from the shipment date. The shipment date is determined by the date on the TIC Bill of Lading. For the 1700 Series the warranty applies if the unit is sent and returned (paid for) by the user to/from the Toshiba plant or a Toshiba designated Authorized Service Center.
If any UPS, part of UPS, and/or BATTERY fails to conform or is defective then TIC will repair or replace it at TIC's option.
LIMITATIONS AND EXCLUSIONS
This limited warranty shall not cover the UPS, UPS part, or BATTERY during their respective warranty periods, if the following storage, maintenance, installation, operating conditions are not met throughout the warranty periods (5 conditions below): VALVE REGUALATED LEAD ACID (VRLA) BATTERIES FOR TOSHIBA UPS REQUIRED OPERATING CONDITIONS Annual Average Temperature per cell < 32°C 1. Temperature Temperature 25°C (77°F) (89°F) for more than 30 days Maximum Number of Cycles (24 months) Discharge time 30 minutes 69 2. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA 1700
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA 1700 will begin.