[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Drill the anchor bolt holes as illustrated in the above figure. Install the installation plate horizontally and level.
10-3-3. The supply voltage must be the same as the rated voltage of the air conditioner. Prepare a power source for the exclusive use of the air conditioner.
NOTE : · Wire type : More than H07RN-F or 245IEC66 (1. 0mm²)
CAUTION
When installing the installation plate with mounting screw, do not use the anchor bolt hole. Otherwise the unit may fall down and result in personal injury and property damage.
CAUTION
· This appliance can be connected to a main circuit breaker in either of the following two ways. Connection to fixed wiring: A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporated in the fixed wiring. An approved circuit breaker or switch must be used. Connection with power supply plug: Attach power supply plug with power cord and plug it into wall outlet. An approved power supply cord and plug must be used.
Anchor bolt Projection 15mm or less
Fig. 10-3-4
NOTE : · Perform wiring work being sure the wire length is long enough.
5 mm dia. Wiring Connection How to connect the connecting cable
7 Mounting screw Ø4 × 25L
Clip anchor (local parts)
Fig. 10-3-13
Left-hand connection with piping
2. Bend the connecting pipes so that they are positioned within 43 mm above the wall surface. If the connecting pipes are positioned more than 43 mm above the wall surface, the indoor unit may be unstable. When bending the connecting pipe, make sure to use a spring bender to avoid crushing the pipe.
No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. If applied, deterioration and drain leakage of the drain plug may occur.
Insert a hexagon wrench (Ø4mm)
Refer to the table below for the bending radius of each connection pipe.
Outer diameter 6. 35 mm 9. 52 mm Bending radius 30 mm 40 mm 50 mm
Fig. 10-3-14
How to attach the drain hose
Always use the original screw that secured the drain hose to the unit. If using a different screw may cause water to leak. Insert the drain hose firmly until the connector contacts with the insulation, then secure it in place using the original screw.
12. 7 mm
To connect the pipe after installation of the unit (figure)
(To the front flare)
220 mm 170 mm
Gas side
CAUTION
Securely insert the drain hose and drain cap; otherwise, water may leak.
Liquid side
R30 or less (Ø6. 35), R40 or less (Ø9. 7) Use polishing (polyethylene core or the like for bending pipe).
43 mm
In case of right or left piping
· After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool.
Outward form of indoor unit
Use a screwdriver handle, etc.
Fig. 10-3-15
NOTE : If the pipe is incorrectly bent, the indoor unit may be unstable on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them.
78
CAUTION
· Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. [. . . ] (B16GKVP-E, M16GKCVP-E) Clamp, Cord
124
13-2. Outdoor Unit
4
41, 42 6 35 23 24 44 33 34 50 36
25 39, 40
43 32
52 12, 45, 47 13, 46, 48 15, 18, 21 14, 17, 20 16, 19, 22 49 27 30 50, 51 9 1 37 2
38
7
5 8
3
29 28 10 31
125
The parts in the following parts list are conformed to RoHS. Therefore be sure to use the following parts for repairing and replacing. 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 20 21 22 23 24 25 28 29 30 31 Part No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA AS200
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.