User manual TOSHIBA BMS-IFDD02E2 INSTALLATION MANUAL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA BMS-IFDD02E2. We hope that this TOSHIBA BMS-IFDD02E2 user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA BMS-IFDD02E2.
Manual abstract: user guide TOSHIBA BMS-IFDD02E2INSTALLATION MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] · After the installation work, perform a trial operation to check for any problem. Follow the Owner's Manual to explain how to use and maintain the unit to the customer. Ask the customer to keep this Installation Manual together with the Owner's Manual.
WARNING
· Ask an authorized dealer or qualified installation professional to install or reinstall the relay interface. [. . . ] · Humid or wet place · Dusty place · Place exposed to direct sunlight · Place where there is a TV set or radio within one meter · Place exposed to rain (outdoors, under eaves, etc. )
Installation Space and Maintenance Space
A side space for connecting through cable inlets and an upper space for maintenance must be reserved before installation. The other sides can be adjacent to surrounding objects.
100mm
100mm
100mm
4
2
Connection of Power cables/Earth wires/ Signal wires
CAUTION
The RS-485 signal wire has polarity. If connected with incorrect polarity, the unit will not work.
REQUIREMENT Disconnect the appliance from the main power supply. This appliance must be connected to the main power supply by a circuit breaker or switch with a contact separation of at least 3mm.
Power cables/Earth wires/Signal wires
Connect power cables, earth wires, and signal wires to the specified terminals on the terminal block.
Secure each cable with a cable clamp.
SW3
ON 1234
SW4
SW7
Connect the earth wire to the earth terminal on the chassis. Power cable
N L
DI4
DI3
DI2
DI1
SW1
SW2
A B FG
DI8
DI7
DI6
DI5
Digital input contacts
Touch Screen Controller
DO1 DO2 DO3 DO4 GND +12V
RS-485
Digital output load
Length of stripped power cable
35 10
Length of stripped communication wire
35 6
Length of stripped digital Input/Output connector wire
35 6
55
10
Insert the wire by pushing the lever with a screwdriver. Check that the wire is inserted securely.
When inserting two RS-485 communication cables into a single terminal for connection to another interface, crimp them using the attached pin terminal.
5
2
Connection of Power cables/Earth wires/ Signal wires (continued)
CAUTION
Wiring Connection
If an inductive load (relay coil) or a bulb is connected, a surge voltage or rush current will be generated. Take adequate measures against surge voltage or rush current. The following describes wiring connections of the Digital Input/Output Relay Interface when it is used in the air conditioner control system.
· Terminator resistor setting
Set the RS-485 terminator resistor by the TCS-NET Relay Interface. Do not set it by the Digital Input/Output Relay Interface.
· Shield earthing
The shield earth of the RS-485 signal wires should be single-point earth. Earth the wires on the Touch Screen Controller. Other shield lines should be closed, and the terminal end should be open and insulated.
· Connection of external digital inputs
Input circuit examples are shown below (electrically isolated using a photo-coupler). (1) Example of contact input connection
12V
(2) Example of current sink connection
12V
Input terminal DI-1 to DI-8 Contact
Input terminal DI-1 to DI-8 Current sink
· Connection of external digital outputs
Output circuit examples are shown below (open collector output electrically isolated using a photocoupler). (1) Example of load connection
12V Output terminal DO1 to DO4 Load External power supply
(2) Example of load connection
12V +12V
GND
Output terminal DO1 to DO4
6
2
Connection of Power cables/Earth wires/ Signal wires (continued)
Crimp 3 wires with a closed end wire joint. Yellow Brown
Connection diagram
A U2 U1 FG NL B
B
Red A Orange
Red/Orange
Brown/Yellow
Power supply
A B
RS-485
TCC-LINK
Connect the shield wire of the two wires
TCS-NET RELAY INTERFACE
SW1
TOUCH SCREEN CONTROLLER
4
ADDRESS
DI 1 DI 2 DI 3 DI 4 DI 5 DI 6 DI 7 DI 8
Input contact 1 Input contact 2 Input contact 3 Input contact 4 Input contact 5 Input contact 6 Input contact 7 Input contact 8 The RS-485 signal wire has polarity A and B. [. . . ] When SW4 is pushed, the respective input status of DI-5 to DI-8 is indicated by LED2 to LED5. (*) To return to the normal operation, reset SW2 to "zero (0)" and push SW7.
SW4 OFF SW4 ON LED2 Displays DI-1 input status. Input ON: LED lights Input OFF: LED turns off LED4 Displays DI-3 input status. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA BMS-IFDD02E2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA BMS-IFDD02E2 will begin.