User manual TOSHIBA KV-9096A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA KV-9096A. We hope that this TOSHIBA KV-9096A user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA KV-9096A.


Mode d'emploi TOSHIBA KV-9096A
Download
Manual abstract: user guide TOSHIBA KV-9096A

Detailed instructions for use are in the User's Guide.

[. . . ] SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONTROL BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OPERATION DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] As the flaring sizes of R410A differ from those of refrigerant R22, the flare tools newly manufactured for R410A are recommended. However, the conventional tools can be used by adjusting projection margin of the copper pipe. B 9-3-7. Installation NOTE : For installation, at least 3 dimensions should be kept free from obstacles (walls). 3. The length and height difference of the connecting pipes between the indoor and outdoor units must be within the ranges indicated below. · Total piping length : Three room (A + B + C) Multi, Non. Additional refrigerant : 40 m or less 600mm or more B C mo 100 re mm fro m wor all re r mo m o wall 50m from · Minimum piping length : A or B or C = 2 m or more · Maximum indoor piping length : A or B or C = 20 m or less · Maximum piping height difference : A or B or C = 10 m or less 9-3-5. Optional Installation Parts (Separate Sold) Parts name RB-M43RE RB-M34EE Reducer (Ø12, 7 Ø9, 52) Expander (Ø9, 52 Ø12, 7) Fig. 9-3-3 m 200 rm mo ore mo 250 re mm fro m wor all · Maximum piping / height difference between two rooms = 10 m or less A 10 m or less C · Projection margin in flaring : B (Unit : mm) Rigid (Clutch type) Outer dia. R410A tool used of copper R410A R22 pipe 6, 35 Conventional tool used R410A R22 As shown in the figure, hang power cord and connecting cable downward, and take out it along piping connection port. Outdoor unit 9-3-6. Refrigerant Piping Connection 9, 52 12, 7 ~ 0, 5 0 ~ 0, 5 0 ~ 0, 5 0 (Same as left) 1, 0 (Same as left) (Same as left) ~ 1, 5 1, 0 ~ 1, 5 1, 0 ~ 1, 5 ~ 1, 0 0, 5 ~ 1, 0 0, 5 ~ 1, 0 0, 5 B Fig. If the outdoor unit is to be mounted on a wall, make sure that the platform supporting it is sufficiently strong. Connect the connecting cable to the terminal as identified with their respective matched numbers on the terminal block of indoor and outdoor unit. When connecting the connecting cable to the outdoor unit terminal, prevent water coming in the outdoor unit. Insulate the unused cords (conductors) with strip the sheath of connecting cable with PVC tape. Process them so that they do not touch any electrical or metal parts. For inter-unit wiring, do not use a cut wire jointed to another on the way. Use wires long enough to cover the entire length. Three room (A + B + C) Multi Terminal block (Connecting cable) Manifold valve Handle Lo Charge hose (For R410A only) Connecting pipe Handle Hi (Keep full closed) Charge hose (For R410A only) Vacuum pump adapter for counter-flow prevention (For R410A only) CAUTION · Do not apply excess torque. Otherwise, the nut may crack depending on the conditions. of copper pipe Ø6, 35 mm Ø9, 52 mm Ø12, 7 mm Tightening torque AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using vacuum pump. Do not use the refrigerant in the outdoor unit. For details, see the manual of vacuum pump. B A Vacuum pump Packed valve at liquid side Service port (Valve core (Setting pin)) Packed valve at gas side ~ 1, 8 kgf·m) 33 ~42 (3, 3 ~ 4, 2 kgf·m) 50 ~62 (5, 0 ~ 6, 2 kgf·m) 14 ~18 (1, 4 Use a vacuum pump Be sure to use a vacuum pump with counter-flow prevention function so that inside oil of the pump does not flow backward into pipes of the air conditioner when the pump stops. [. . . ] 9) Wind the attached color tape round the both terminals of the protective tube when colored protective tube is used. NOTES : 1) Store the joint part of the sensor and the connector in the electric parts box. 2) Never joint them near the thermal sensor part. Otherwise it would cause insulation inferiority because of dew drops. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA KV-9096A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA KV-9096A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag