User manual TOSHIBA MMK-AP0073H DATA BOOK

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA MMK-AP0073H. We hope that this TOSHIBA MMK-AP0073H user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA MMK-AP0073H.


Mode d'emploi TOSHIBA MMK-AP0073H
Download

You may also download the following manuals related to this product:

   TOSHIBA MMK-AP0073H SERVICE MANUAL (4702 ko)

Manual abstract: user guide TOSHIBA MMK-AP0073HDATA BOOK

Detailed instructions for use are in the User's Guide.

[. . . ] [. . . ] Normally, the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound. Note : Rated conditions Cooling : Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB Heating : Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB 2 EN Engineering Data 2 Dimensions 1050 Model : MMK-AP0073H, AP0093H, AP0123H, AP0153H, AP0183H, AP0243H Front panel Air filter Air inlet 228 73. 5 320 7 50 Heat exchanger 50 Knock out system Knock out system 50 7 163 204 Installation plate hanger 132 568 200 72 78 56 24 150 Wireless remote controller 82 73. 5 26 Remote controller holder Installation plate hanger Connecting pipe (0. 39m) (07, 09, 12 series; 9. 5mm 15, 18 series; 12. 7mm 24 series; 15. 9mm) 132 235 215 Hanger 85 23 786 235 215 Drain hose (0. 5mm) Connecting pipe (0. 44m) (07, 09, 12 series; 6. 4mm 15, 18 series; 6. 4mm 24 series; 9. 5mm) 132 Space required for installation and servicing 320 40 Hanger 47 215. 5 Center line 262. 5 Hanger 262. 5 153. 5 109 40 Distance A 110 or more 850 or more 170 or more B C Comments For exchange of cross flow fan Installation plate outline Installation plate EN 3 Engineering Data 3 Center of gravity Distance to center of gravity (mm) X Y Z 445 105 170 Model : MMK-AP0073H, AP0093H, AP0123H, AP0153H, AP0183H, AP0243H 4 EN Engineering Data 4 Electrical current characteristics Type Model MMK-AP0073H MMK-AP0093H MMK-AP0123H MMK-AP0153H MMK-AP0183H MMK-AP0243H MMK-AP0073H MMK-AP0093H MMK-AP0123H MMK-AP0153H MMK-AP0183H MMK-AP0243H Nominal Voltage (V-Ph-Hz) 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 220-1-60 Voltage Range Min 198 198 198 198 198 198 198 198 198 198 198 198 Fan Motor kW 0. 030 0. 030 0. 030 0. 030 0. 030 0. 030 0. 030 0. 030 0. 030 0. 030 0. 030 0. 030 Power Supply MCA 0. 22 0. 24 0. 24 0. 40 0. 40 0. 47 0. 22 0. 24 0. 24 0. 40 0. 40 0. 47 Max 264 264 264 264 264 264 242 242 242 242 242 242 FLA 0. 20 0. 22 0. 22 0. 37 0. 37 0. 43 0. 20 0. 22 0. 22 0. 37 0. 37 0. 43 MOCP 15 15 15 15 15 15 15 15 15 15 15 15 50Hz High Wall Type 60Hz High Wall Type EN 5 Engineering Data 5 unit size Sensible capacity table outdoor air temp. CDB 10. 0 12. 0 14. 0 16. 0 18. 0 20. 0 21. 0 23. 0 25. 0 27. 0 29. 0 31. 0 33. 0 35. 0 37. 0 39. 0 10. 0 12. 0 14. 0 16. 0 18. 0 20. 0 21. 0 23. 0 25. 0 27. 0 29. 0 31. 0 33. 0 35. 0 37. 0 39. 0 10. 0 12. 0 14. 0 16. 0 18. 0 20. 0 21. 0 23. 0 25. 0 27. 0 29. 0 31. 0 33. 0 35. 0 37. 0 39. 0 High Wall Type ( MMK-AP0***3H ) 14. 0CWB 20CDB TC 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 7 1. 7 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 2 2. 2 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 3. 0 2. 9 2. 8 SHC 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 5 1. 4 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 8 1. 7 1. 7 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 1 2. 1 16. 0CWB 23CDB TC 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 1. 9 1. 9 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 4 3. 3 3. 3 3. 3 3. 3 3. 3 3. 3 3. 3 3. 3 3. 3 3. 3 3. 3 3. 3 3. 3 3. 3 3. 2 3. 1 SHC 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 5 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 8 1. 8 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 3 2. 2 18. 0CWB 26CDB TC 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 1 2. 0 2. 7 2. 7 2. 7 2. 7 2. 7 2. 7 2. 7 2. 7 2. 7 2. 7 2. 7 2. 7 2. 7 2. 7 2. 6 2. 6 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 5 3. 4 3. 3 SHC 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 6 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 1. 9 1. 9 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 4 2. 4 indoor air temp. 19. 0CWB 27CDB TC 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 2 2. 1 2. 1 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 8 2. 7 2. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 6 3. 5 3. 4 SHC 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 6 1. 6 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 1. 9 1. 9 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 4 2. 4 20. 0CWB 28CDB TC 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 3 2. 2 2. 1 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 9 2. 8 2. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 7 3. 6 3. 5 SHC 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 6 1. 6 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 1. 9 1. 9 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 4 2. 4 22. 0CWB 30CDB TC 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 3 2. 3 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 1 3. 0 2. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 9 3. 8 3. 7 SHC 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 7 1. 6 1. 6 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 2. 0 1. 9 1. 9 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 4 2. 3 24. 0CWB 32CDB TC 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 5 2. 4 2. 4 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 1 3. 0 4. 1 4. 1 4. 1 4. 1 4. 1 4. 1 4. 1 4. 1 4. 1 4. 1 4. 1 4. 1 4. 1 4. 1 4. 0 3. 9 SHC 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 6 1. 5 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 9 1. 8 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 4 2. 3 2. 3 007 009 012 TC : Total capacity [kW] SHC : Sensible capacity [kW] 6 EN Engineering Data High Wall Type ( MMK-AP0***3H ) unit size outdoor air temp. [. . . ] [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA MMK-AP0073H

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA MMK-AP0073H will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag