User manual TOSHIBA RAS-10NKVX-T SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-10NKVX-T. We hope that this TOSHIBA RAS-10NKVX-T user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAS-10NKVX-T.


Mode d'emploi TOSHIBA RAS-10NKVX-T
Download
Manual abstract: user guide TOSHIBA RAS-10NKVX-TSERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] SVM-06032 SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-10GKV-E2 / RAS-10GAV-E2 RAS-13GKV-E2 / RAS-13GAV-E2 RAS-16GKV-E2 / RAS-16GAV-E2 RAS-10NKV-A2 / RAS-10NAV-A2 RAS-13NKV-A2 / RAS-13NAV-A2 RAS-16NKV-A2 / RAS-16NAV-A2 RAS-10NKVX-T / RAS-10NAVX-T RAS-13NKVX-T / RAS-13NAVX-T June, 2006 FILE NO. SPECIFICATIONS 1-1 1-2 1-3 Specifications Operation Characteristic Curve Capacity Variation Ratio According to Temperature Safety During Installation/Servicing Refrigerant Piping Installation Tools Recharging of Refrigerant Brazing of Pipes Indoor Unit Outdoor Unit Indoor Unit (For 10, 13 Series) Indoor Unit (For 16 Series) Outdoor Unit (For 10 Series) Outdoor Unit (For 13, 16 Series) Indoor Unit (For 13NKV) Indoor Unit (For 16NKV) Outdoor Unit (For 10NAV) Outdoor Unit (For 13NAV) Outdoor Unit (For 16NAV) Refrigerant Cycle Diagram Operation Data Indoor Unit Outdoor Unit (Inverter Assembly) Outlined of Air Conditioner Control Description of Operation Circuit Temporary Operation Auto Restart Function Filter Check Lamp Remote Control and its Functions Safety Cautions Indoor Unit Outdoor Unit - 1- 2. REFRIGERANT R410A 2-1 2-2 2-3 2-4. 2-5. 3. CONSTRUCTION VIEWS 3-1 3-2 4. WIRING DIAGRAM 4-1 4-2 4-3 4-3 5. SPECIFICATION OF ELECTRICAL PARTS 5-1 5-2 5-3 5-4 5-5 6. REFRIGERANT CYCLE DIAGRAM 6-1 6-2 7. CONTROL BLOCK DIAGRAM 7-1 7-2 8. OPERATION DESCRIPTION 8-1 8-2 8-3 8-4 8-5 8-6 9. INSTALLATION PROCEDURE 9-1 9-2 9-3 FILE NO. SVM-06032 9. INSTALLATION PROCEDURE 9-1 9-2 9-3 10-1 10-2 10-3 10-4 10-5 10-6 10-7 10-8 10-9 Safety Cautions Indoor Unit Outdoor Unit First Confirmation Primary Judgment Judgment by Flashing LED of Indoor Unit Self-Diagnosis by Remote Control (Check Code) Judgment of Trouble by Every Symptom Check Code 1C (Miswiring in indoor/outdoor units) and 1E How to Diagnose Trouble in Outdoor Unit How to Check Simply the Main Parts How to Simply Judge Whether Outdoor Fan Motor is Good or Bad 10. [. . . ] When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. An allowable length of the connecting pipe is up 15 m. An allowable height level is up to 10 m. A place where the drain water does not raise any problem. 9-3-2. Refrigerant piping connection <Flaring> 1. Cut the pipe with a pipe cutter. Obliquity Roughness Warp 90 Fig. Insert a flare nut into the pipe, and flare the pipe. Projection margin in flaring : A (Unit : mm) A Die Pipe Fig. Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always exposed to strong wind like a coast or on a high storey of a building, secure the normal fan operation using a duct or a wind shield. In particularly windy areas, install the unit such as to avoid admission of wind. Installation in the following places may result in trouble. A place where high-frequency waves are likely to be generated as from audio equipment, welders, and medical equipment. Rigid (Clutch type) Outer dia. of copper pipe R410A tool used Conventional tool used 6. 35 9. 52 12. 70 0 to 0. 5 0 to 0. 5 0 to 0. 5 1. 0 to 1. 5 1. 0 to 1. 5 1. 0 to 1. 5 Imperial (wing nut type) Outer dia. of copper pipe 6. 35 9. 52 12. 70 R410A 1. 5 to 2. 0 1. 5 to 2. 0 2. 0 to 2. 5 <Tightening connection> Align the centers of the connecting pipes and tighten the flare nut as far as possible with your fingers. Then tighten the nut with a spanner and torque wrench as shown in the figure. Half union Flare nut Strong wind Externally threaded side Internally threaded side Use a torque wrench to tighten. Fig. 9-3-1 Use a wrench to secure. Fig. 9-3-4 CAUTION Do not apply excess torque. Otherwise, the nut may crack depending on the conditions. 62 FILE NO. of copper pipe 6. 35 mm 9. 52 mm 12. 70 mm Tightening torque 16 to 18 (1. 6 to 1. 8 kgfm) 30 to 42 (3. 0 to 4. 2 kgfm) 50 to 62 (5. 0 to 6. 2 kgfm) After the piping has been connected to the indoor unit, you can perform the air purge together at once. AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump. Do not use the refrigerant in the outdoor unit. [. . . ] 1 2 3 4 5 6 7 8 9 10 11 12 13 Part No. 43T19313 43T20306 43T00438 43T43366 43T62323 43T00439 43T47308 43T46331 43T47332 43T46332 43T47331 43T21374 43T47001 Description FAN GUARD PROPELLER FAN FRONT CABINET CONDENSOR ASSEMBLY TERMINAL COVER BACK CABINET CAPILLARY TUBE; 1. 0 DIA VALVE;PACKED 9. 52 DIA BONNET, 9. 52 DIA VALVE;PACKED 6. 35 DIA BONNET, 6. 35 DIA FAN-MOTOR (HF-240-20B-2R) NUT FLANGE Location No. 14 15 17 18 19 20 21 22 23 24 25 26 Part No. 43T19312 43T49327 43T54313 43T41358 43T62305 43T00440 43T63312 43T42323 43T79305 43T46313 43T46333 43T46334 Description HANDLE CUSHION, RUBBER BIMETAL THERMO COMPRESSOR (DA89X1C-23FZ) PACKED VALVE COVER UPPER CABINET FIXING PLATE VALVE BASE COATING ASSEMBLY DRAIN NIPPLE REACTOR 4 WAY VALVE COIL-4WAY ASSEMBLY - 108 - FILE NO. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-10NKVX-T

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-10NKVX-T will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag