If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-137SAV-E. We hope that this TOSHIBA RAS-137SAV-E user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAS-137SAV-E.
Manual abstract: user guide TOSHIBA RAS-137SAV-ESERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] SVM-08011-1
SERVICE MANUAL
SPLIT TYPE
Indoor Unit
<High Wall, Heat Pump Type>
Outdoor Unit
<Heat Pump Type>
RAS-137SKV-E RAS-167SKV-E
RAS-137SAV-E RAS-167SAV-E
R410A
Revised Mar, 2008
FILE NO. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Insert the drain hose firmly until the connector contacts with the insulation, then secure it in place using the original screw.
9. 52 mm 12. 7 mm
To connect the pipe after installation of the unit (figure)
(To the front flare)
270 mm
Gas side
CAUTION
Securely insert the drain hose and drain cap; otherwise, water may leak.
230 mm
Liquid side
R30 or less (6. 35), R40 or less (9. 7) Use polishing (polyethylene core or the like for bending pipe).
43 mm
In case of right or left piping
After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool.
Outward form of indoor unit
Use a screwdriver handle, etc.
Fig. 10-3-15
NOTE : If the pipe is incorrectly bent, the indoor unit may be unstable on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them.
55
FILE NO. SVM-08011
CAUTION
Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape.
Indoor unit Auxiliary pipes Installation plate Connecting cable
10-3-7. Run the drain hose at a downward sloped angle.
NOTE : Hole should be made at a slight downward slant on the outdoor side.
Do not rise the drain hose. Do not form the drain hose into the waved shape.
50 mm or more
Fig. 10-3-18 Carefully arrange the pipes so that none of the pipes stick out of the rear plate of the indoor unit. Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint, moreover, seal the joint with the vinyl tape, etc. Since condensation can result in machine performance trouble, be sure to insulate both connecting pipes. (Use polyethylene foam as insulating material. ) When bending a pipe, be careful not to crush it.
Do not put the drain hose end into water.
Do not put the drain hose end in the drainage ditch.
Fig. Put water in the drain pan and make sure that the water is being drained outside. When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe.
Shield pipe
10-3-6. Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks. Swing the indoor unit to right and left to confirm that it is firmly hooked on the installation plate. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confirm that it is firmly hooked on the installation plate.
1
Drain hose Inside the room
Extension drain hose
Fig. 10-3-22
CAUTION
Install the drain pipe for proper drainage. Improper drainage can result in water dripping inside the room. This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit, to the drain pan. Therefore, do not locate the power cord and other parts at a high place than the drain guide.
Hook here 1 Installation plate
2
Hook
Push (unhook)
Fig. [. . . ] 2) Cut the protective tube after pulling out it (200 mm). 3) Move the protective tube toward the thermal sensor side and tear the tip of lead wire in two then strip the covering part. 4) Pass the stripped part through the thermal constringent tube. 5) Cut the old sensor 100 mm length on the connector side, and recycle that connector. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-137SAV-E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.