User manual TOSHIBA RAS-18PKVSG-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-18PKVSG-E. We hope that this TOSHIBA RAS-18PKVSG-E user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAS-18PKVSG-E.


Mode d'emploi TOSHIBA RAS-18PKVSG-E
Download
Manual abstract: user guide TOSHIBA RAS-18PKVSG-E

Detailed instructions for use are in the User's Guide.

[. . . ] — This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. — Children should be supervised to ensure that they do not play with the appliance. — Do not use any refrigerant different from the one specified for complement or replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body. [. . . ] " # REMOTE CONTROL Infrared signal emitter Start/Stop button Mode select button (MODE) Temperature button (TEMP) Fan speed button (FAN) Swing louver button (SWING) Set louver button (FIX) Off timer button (OFF) High power button (Hi-POWER) Economy button (ECO) Clear button (CLEAR) Check button (CHECK) 1 3 2 7 9 8 # 4 6 5 !Open the air inlet grille and remove the air filters. Insert 2 new batteries (AAA type) following the (+) and (–) positions. 8 Hi-POWER OPERATION To automatically control room temperature and airflow for faster cooling or heating operation (except in DRY and FAN ONLY mode) Press : Start and stop the operation. 9 ECO OPERATION 15 OPERATION AND PERFORMANCE 1. Three-minute protection feature: To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON. Preheating operation: Warm up the unit for 5 minutes before the heating operation starts. Warm air control: When the room temperature reaches the set temperature, the fan speed is automatically reduced and the outdoor unit will stop. Heating capacity: Heat is absorbed from outdoors and released into the room. When the outdoor temperature is too low, use another recommended heating apparatus in combination with the air conditioner. Consideration for accumulated snow: Select the position for outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris. Some minor cracking sound may occur when unit operating. This is normal because the cracking sound may be caused by expansion/ contraction of plastic. Note: Item 2 to 6 for Heating model Air conditioner operating conditions Temp. Outdoor Temperature Room Temperature Less than 28°C 21°C ~ 32°C 17°C ~ 32°C To automatically control room to save energy (except in DRY and FAN ONLY mode) Press : Start and stop the operation. Note: Cooling operation; the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation the set temperature will decrease. 10 TEMPORARY OPERATION In case of the misplaced or discharged remote control ● Pressing the RESET button, the unit can start or stop without using the remote control. ● Operation mode is set on AUTOMATIC operation , preset temperature is 24°C and fan operation is automatic speed. EN ES FR IT DE PT PL CZ CR HU NL GR FI DK RO BG EE LV SK 11 TIMER OPERATION Set the timer when the air conditioner is operating. Setting the OFF timer 1 Press for enter OFF timer setting. Operation Heating Cooling Dry –15°C ~ 24°C –10°C ~ 46°C –10°C ~ 46°C 16 TROUBLESHOOTING (CHECK POINT) The unit does not operate. [. . . ] €œB” will show on the display and “00” will disappear and the air conditioner will turn OFF. Repeat above step to reset Remote Control to be A. 13 MAINTENANCE Firstly, turn off the circuit breaker. Indoor Unit and Remote Control ● Clean the indoor unit and the remote control with a wet cloth when needed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-18PKVSG-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-18PKVSG-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag