If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-3M23GACV-E. We hope that this TOSHIBA RAS-3M23GACV-E user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAS-3M23GACV-E.
You may also download the following manuals related to this product:
TOSHIBA RAS-3M23GACV-E DATA BOOK (41 ko)
Manual abstract: user guide TOSHIBA RAS-3M23GACV-ESERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] A05-014
SERVICE MANUAL
SPLIT TYPE
<Cooling OnlyType>
Indoor Unit
RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E
Outdoor Unit
RAS-3M23GACV-E
R410A
PRINTED IN JAPAN, Jan. , 2006 ToMo
CONTENTS
1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe.
Shield pipe
10-3-6. Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks. Swing the indoor unit to right and left to confirm that it is firmly hooked on the installation plate. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confirm that it is firmly hooked on the installation plate.
1
Drain hose Inside the room
Extension drain hose
Fig. 10-3-22
CAUTION
Install the drain pipe for proper drainage. Improper drainage can result in water dripping inside the room. This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit, to the drain pan. Therefore, do not locate the power cord and other parts at a high place than the drain guide.
Hook here 1 Installation plate
2
Hook
Push (unhook)
Fig. 10-3-19 · For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing the bottom up at the specified places.
Wall Drain guide
Space for pipes
Push Push
Fig. Optional Parts, Accessories and Tools Optional installation parts
Part name Indoor unit name (Abbreviation) Refrigerant piping *1 RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E Putty, PVC tapes Specifications Liquid side (Outer diameter) 6. 35 mm 6. 35 mm Gas side (Outer diameter) 9. 52 mm 12. 7 mm 1 ea. Q'ty
*1 Refrigerant piping covered with insulating material (polyethylene form, 6 mm thick. ). In case the piping installed above the ceiling, it shall be covered with thicker insulating material (polyethylene form, 10 mm thick. ).
Accessory and installation parts
Part No. Part name (Q'ty) Others
Outdoor unit installation manual × 1
Specifications × 1
Name Important information and warning B/W strips (Energy efficiency labels)
10-4-2. Which Models can be Combined
Table of models that can be connected
Type Outdoor unit Indoor unit RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E RAS-M10GKCV-E, RAS-M13GKCV-E, RAS-M16GKCV-E RAS-M10GDCV-E, RAS-M13GDCV-E, RAS-M16GDCV-E
Cooling only
RAS-3M23GACV-E
Table of models that can be used in combination
Type Outdoor unit Combinations of indoor unit models that can be connected 10, 13, 16, 10 + 10, 10 + 13, 10 + 16, 13 + 13, 13 + 16, 16 + 16, 10 + 10 + 10, 10 + 10 + 13, 10 + 13 + 13, 10 + 10 + 16
Cooling only
RAS-3M23GACV-E
55
10-5. Installation Location
· A place which provides enough space around the outdoor unit as shown in the figure. · A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration. · A place where the operation noise and discharged air do not disturb neighbors. · A place which is not exposed to a strong wind. · A place free of combustible gases. · A place which does not block a passageway. · When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. [. . . ] Therefore be sure to use the following parts for repairing and replacing. 201 202 203 204 205 206 207 209 210 211 212 213 214 215 216 217 218 219 221 222 223 Part No. 43005633 43005610 4301V052 43080512 43080521 43009675 43009682 4302C067 4302C063 4306A024 43039363 43039321 43020346 43039314 43020253 4301V028 43049701 43049698 43047671 43047672 43049674 Description Panel Ass'y, Front Grille, Air Inlet Plate, Fix Filter, Air, Right Filter, Air, Left Louver, Horizontal Louver, Vertical Motor, Fan Motor, Louver Cord, Motor, Louver Band, Motor, Left Base, Bearing Fan, Cross Flow Band, Motor Bearing Holder, Pipe Pipe, Shield (*1) Pipe, Shield (*2) Pipe, Outlet (*2) Pipe, Outlet (*1) Spring, Suction (*1) Location No. 224 225 226 227 228 229 230 232 233 234 235 236 238 239 240 245 246 247 Part No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-3M23GACV-E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.