If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-3M26GAV-E. We hope that this TOSHIBA RAS-3M26GAV-E user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAS-3M26GAV-E.
Manual abstract: user guide TOSHIBA RAS-3M26GAV-EDATA BOOK
Detailed instructions for use are in the User's Guide.
[. . . ] PARTS REPLACEMENT
10-1 Indoor Unit 10-2 Outdoor Unit
11. EXPLODED VIEWS AND PARTS LIST
11-1 11-2 11-3 11-4 11-5 11-6 11-7 Indoor Unit (E-Parts Assy) (For RAS-13GKHP-ES2) Indoor Unit (E-Parts Assy) (For RAS-13NKHP-AS2) Indoor Unit (E-Parts Assy) (For RAS-13GKP-ES2) Indoor Unit (E-Parts Assy) (For RAS-13NKP-AS2) Indoor Unit Outdoor Unit (RAS-3M26GAV-E, RAS-13N2AH-AS2) Outdoor Unit (RAS-13GA-ES2, RAS-13N2A-AS2)
· This air conditioner is charged with HFC (R410A) that doesn't deplete the Ozone layer. · This air conditioner requires special installation for the refrigerant R410A.
-2-
FILE NO. SPECIFICATIONS
MODEL ITEM Capacity 220V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB dB kg mm mm m m RAS-13GKHP-ES2 RAS-13NKHP-AS2 Height Dimensions Net weight Evaporator type Indoor fan type High fan Airflow volume Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range °C 15 ~ 43 Model Output W m /h
3
RAS-13GKHP-ES2 / RAS-3M26GAV-E RAS-13NKHP-AS2 / RAS-13N2AH-AS2 Cooling 240V 3. 82 220V 4. 20 1 220 - 240 50 1. 15 98 5. 20 1. 19 96 5. 00 30 2. 0 41/35/31 50 51 50 R410A 1. 08 Capillary tube 12. 7 Flare connection 6. 35 Flare connection 15*1 6 51 1. 14 96 0. 15 5. 27 5. 18 1. 18 95 3. 74 Heating 240V 4. 26
RAS-13GKP-ES2 / RAS-13GA-ES2 RAS-13NKP-AS2 / RAS-13N2A-AS2 Cooling 220V 3. 75 240V 3. 75
1. 13 98 5. 10 26
1. 17 97 4. 90
Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Outdoor (220-240V) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type Maximum length pipe (One way) Maximum height difference INDOOR UNIT
50 0. 98
51
Refrigerant control
RAS-13GKP-ES2 RAS-13NKP-AS2 275 790 218 10 Finned tube Cross flow fan
mm mm mm kg
Width Depth
m3/h m /h
3
630 520 430
650 550 490 20 Honeycomb woven filter with PP frame
630 520 430
m3/h W
RAS-3M26GAV-E, RAS-13N2AH-AS2 mm mm mm kg 39 Finned tube Propeller fan 2120 2200 42 PA150X2C-4FT 1100 Fuse, Overload relay Automatic louver -10 ~ 24 2120 2200 550 780 290
RAS-13GA-ES2, RAS-13N2A-AS2
Width Depth
38
2030 30
2150
W
15 ~ 43
-3-
FILE NO. [. . . ] 8-4-7
Earth line
60 mm 10 mm
CAUTION
· Be sure to refer to the wiring system diagram labeled inside the front panel. · Check local electrical cords and also any specific wiring instructions or limitations. For Heat pump
Terminal cover Cord clamp Terminal block
10 mm 50 mm
Stripping length of the connecting cable
Fig. 8-4-8 NOTE · Use stranded wire only. · Wire type : H07 RN-F or more <How to install the air inlet grille on the indoor unit> · When attaching the air inlet grille, the contrary of the removed operation is performed.
Screw Connecting cable
abo
4
4
12
3
12
3
ut 1
5 cm
Earth line
Screw
Screw
Connecting cable
Fig. 8-4-5
Earth line
80 mm 10 mm 70 mm
Fig. 8-4-9
10 mm
10 mm 50 mm
Stripping length of the connecting cable
Fig. Piping and drain hose installation <Piping and drain hose forming> * Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material. ) Rear right
4 mm
How to fix the drains cap 1) Insert hexagonal wrench (4 mm) in a center head.
Left Bottom right Right
Die-cutting Front panel slit
Bottom left
Changing drain hose
Rear left
Piping preparation
Fig. 8-4-12 2) Firmly insert drains cap.
No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. Application causes deterioration and drain leakage of the plug. · Since dewing results in a machine trouble, make sure to insulate both the connecting pipes. (Use polyethylene foam as insulating material. ) · When bending a pipe, carefully do it, not to crush it. NOTE · Hole should be made at a slight downward slant on the outdoor side.
Do not rise the drain hose. Do not form the drain hose into a wavy shape.
8-5. Installation place · A place which provides the spaces around the outdoor unit as shown in the left diagram. · A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration. · A place where the operation noise and discharged air do not disturb your neighbors. · A place which is not exposed to a strong wind. · A place free of a leakage of combustible gases. · A place which does not block a passage. · When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. [. . . ] Part name Procedures Remarks
4
Heat exchanger
1) Remove the front panel, electrical part and the horizontal louver following procedure 3. 2) Remove the pipe holder at the rear side of main unit. 3) Remove the 2 screws on the heat exchanger at the base bearing. 4) Remove the 2 screws on the heat exchanger at the 2 fixed plates (upper and lower) from the back body, and then pull out the upper side of the heat exchanger slowly.
2 Pipe holder
3 2-Screws
4 2-Screws
5
Cross flow fan
1) Remove the front panel, electrical part, horizontal louver and the heat exchanger following procedure 4. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-3M26GAV-E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.