If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-4M26SACV. We hope that this TOSHIBA RAS-4M26SACV user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAS-4M26SACV.
Manual abstract: user guide TOSHIBA RAS-4M26SACVSERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] FILE NO. A07-007 Revised 1: Jul. , 2008
SERVICE MANUAL
AIR-CONDITIONER
SPLIT TYPE
RAS-M10SKCV, RAS-M13SKCV, RAS-M16SKCV, RAS-M22SKCV, RAS-M22NKCV1 / RAS-4M26SACV
R410A
PRINTED IN JAPAN, Jul. , 2008 ToMo
CONTENTS
1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] NOTE: Three-minutes protection feature A protection feature prevents the air conditioner from being activated for about 3 minutes when it is restarted immediately after operation or when the power switch is turned on. Explain to the customer on the correct usage of air conditioner simple layman's terms. 10-4-1
[MODE] button
[CHK] button
69
When the installation plate is directly mounted on the wall
1. Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated above. Install the installation plate horizontally in the wall.
10-4-3. The supply voltage must be the same as the rated voltage of the air conditioner. Prepare a power source for exclusive use with the air conditioner.
NOTE : · Wire type : More than 1. 5mm² (H07RN-F or 245IEC66) or 1. 3mm² (AWG-16)
CAUTION
· Use power specified above table. · This appliance can be connected to a mains in either of the following two ways. Connection to fixed wiring: A switch or circuit breaker which disconnects all poles and has a contact separation of at least 3 mm must be incorporated in the fixed wiring. An approved circuit breaker or switches must be used.
CAUTION
When installing the installation plate with mounting screw, do not use the anchor bolt hole. Otherwise the unit may fall down and result in personal injury and property damage.
Anchor bolt Projection 15mm or less
NOTE : · Perform wiring work so as to allow a generous wiring capacity.
Fig. hole
Air Inlet grille
Front panel
7 Mounting screw Ø4 × 25L Clip anchor (local parts)
2 1
Fig. 10-4-4
Terminal block
CAUTION
Failure to firmly install the unit may result in personal injury and property damage if the unit falls. · In case of block, brick, concrete or similar type walls, make 5 mm dia. · Insert clip anchors for appropriate mounting screws.
Terminal cover
Cord clamp Earth line Screw
Screw
Connecting cable
NOTE : · Secure four corners and lower parts of the installation plate with 6 to 8 mounting screws to install it.
Fig. Installation Place
· A place which provides the spaces around the indoor unit as shown in the above diagram. · A place where there is no obstacle near the air inlet and outlet. · A place which allows an easy installation of the piping to the outdoor unit. · A place which allows the front panel to be opened.
10-4-5. Cutting a Hole and Mounting Installation Plate Cutting a hole
When install the refrigerant pipes from the rear.
CAUTION
· Direct sunlight to the indoor unit wireless receiver should be avoided. · The microprocessor in the indoor unit should not be too close to r-f noise sources. [. . . ] 43T39023 43T39022 43T09040 43T03014 43T44031 43T03041 43T09041 43T80019 43T00052 43T62031 43T69616
Description Band, Motor, Right down Band, Motor, Right up Louver, Horizontal Body Ass'y, Back Evaporator Ass'y Grille Ass'y, Sub TOSHIBA Grille Ass'y, Sub TOSHIBA Air filter Panel Ass'y, Service Cover, Terminal Remote controller, Wireless
135
RAS-M22NKCV1
221 213 229 228
219
220
215
214
232
230 227 208 217
222
218 216 211 209 231 226 224
201 203
202 212 223 207 234 204 236 233 235
210
Location No. 201 202 203 204 207 208 209 210 211 212 213 214 215 216 217 218 219
Part No. 43T00409 43T09351 43T80306 43T80312 43T03010 43T03011 43T03012 43T09345 43T70301 43T21302 43T44361 43T47006 43T47016 43T49021 43T19003 43T49009 43T49036
Description Front Panel Ass'y Grille Ass'y Air Filter (Left) Air Filter (Right) Body, Right Body, Left Hide, Claw Louver-H Hose Ass'y, Drain Motor, Stepping Refrigeration Cycle Ass'y Pipe, Delivery Pipe, Suction Pipe, Shield Fix-P-Sensor Spring Plate, EVA-Seal
Location No. 220 221 222 223 224 226 227 228 229 230 231 232 233 233 234 235 236
Part No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-4M26SACV
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-4M26SACV will begin.