User manual TOSHIBA RAS-4M27YACV-E SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-4M27YACV-E. We hope that this TOSHIBA RAS-4M27YACV-E user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAS-4M27YACV-E.


Mode d'emploi TOSHIBA RAS-4M27YACV-E
Download
Manual abstract: user guide TOSHIBA RAS-4M27YACV-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] FILE NO. SVM-04015 SUPPLEMENT SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10UKV-E3, RAS-M13UKV-E3, RAS-M16UKV-E3 RAS-4M27YAV-E RAS-M10UKCV-E3, RAS-M13UKCV-E3, RAS-M16UKCV-E3 RAS-4M27YACV-E RAS-M10UKV-E3, RAS-M13UKV-E3, RAS-M16UKV-E3 RAS-3M26YAV-E R410A May 2004 CONTENTS 1. SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Application causes deterioration and drain leakage of the plug. Insert a hexagon wrench (4 mm) NOTE · Use stranded wire only. 9-2-5 CAUTION Firmly insert the drain hose and drain cap; otherwise, water may leak. ­ 68 ­ Die-cutting Front panel slit Fig. 9-2-9 Piping preparation Changing drain hose Rear left In case of right or left piping · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. Slit 9-2-6 Indoor Unit Fixing 1. Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks. Swing the indoor unit to right and left to confirm that it is firmly hooked up on the installation plate. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confirm that it is firmly hooked up on the installation plate. Hook here 1 Fig. 9-2-10 In case of bottom right or bottom left piping · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. 1 Installation plate Slit 2 Hook Press (unhook) Fig. 9-2-14 · For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing its bottom up at the specified parts. Left-hand connection with piping Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall. When bending the connecting pipe, make sure to use a spring bender so as not to crush the pipe. Bend the connection pipe within a radius of 30 mm (Ø6. 35) 40 mm (Ø9. 52). To connect the pipe after installation of the unit (figure) (To the forefront of flare) 270 mm 170 mm Push Push Fig. 9-2-15 Liquid side Gas side 9-2-7 Drainage 1. Run the drain hose sloped downwards. NOTE Outward form of indoor unit 43 mm · Hole should be made at a slight downward slant on the outdoor side. Do not rise the drain hose. Do not form the drain hose into the waved shape. R30 or less (Ø6. 35) R40 or less (Ø9. 52) (Use polisin (polyethylene core or the like for bending pipe. ) ° 80 Use the handle of screwdriver, etc. 50 mm or more Fig. 9-2-12 NOTE If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them. Do not put the drain hose end into water. Do not put the drain hose end in the drainage ditch. Fig. Put water in the drain pan and make sure that the water is drained out of doors. When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe. Shield pipe CAUTION · Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. [. . . ] MCC-867 (RAS-M16UKCV-E3) ­ 110 ­ 217 Indoor Unit RAS-M10UKV-E3, RAS-M13UKV-E3, RAS-M16UKV-E3, RAS-M10UKCV-E3, RAS-M13UKCV-E3, RAS-M16UKCV-E3 212 219 220 201 205 216 217 214 210 211 215 218 208 203 225 207 204 233 222 223 202 221 209 231 232 Electric Parts Assembly 224 229 204 234 206 228 226 227 Location Part No. 201 202 203 204 205 206 206 207 208 209 210 210 211 212 212 214 214 215 216 Description Location Part No. No. 217 218 219 220 221 222 223 224 225 226 226 227 228 228 228 229 231 232 233 234 43T49006 43T79302 43T22002 43T39301 43T20302 43T39302 43T21327 43T39303 43T82301 43T69310 43T69327 43T83003 43T85425 43T85426 43T85457 43T62302 43T60317 43T60316 43T07303 43T01303 Description Holder For Plate Guide Drain Asm M Bearing Base Bearing Fan Cross Flow Band Motor-L Motor Fan Band Motor-R Plate Installation Wireless Remocon (For RAS-M10, 13, 16UKCV-E3) Wireless Remocon (For RAS-M10, 13, 16UKV-E3) Holder Remote Controller Owner's Manual Owner's Manual Owner's Manual Terminal Cover Cord Motor Louver Cord Motor Fan Holder Pipe Mark 43T00391 Front Panel Assy 43T09326 Inlet Grille Assy 43T03302 Back body Assy 43T80301 Air Filter 43T09328 Horizontal Louver 43T08392 LED Panel Assy (For RAS-M10, 13, 16UKV-E3) 43T08393 LED Panel Assy (For RAS-M10, 13, 16UKCV-E3) 43T70002 Drain Hose 43T79301 Cap Drain 43T21321 Motor Stepping 43T44341 Refrigeration Cycle Assy (For RAS-M10, 13UKV-E3/UKCV-E3) 43T44342 Refrigeration Cycle Assy (For RAS-M16UKV-E3/UKCV-E3) 43T47006 Pipe Delivery 43T47016 Pipe Suction (For RAS-M16UKV-E3/UKCV-E3) 43T47305 Pipe Suction (For RAS-M10, 13UKV-E3/UKCV-E3) 43T11301 Pipe Shield (For RAS-M10, 13UKV-E3/UKCV-E3) 43T11302 Pipe Shield (For RAS-M16UKV-E3/UKCV-E3) 43T19302 Holder Sensor 43T49302 Plate Of Eva Seal ­ 111 ­ 12. 2. Outdoor Unit RAS-4M27YAV-E/ RAS-4M27YACV-E/ RAS-3M26YAV-E 4 6 39 43 34 32 33 11, 42 35 23 24 25 26 12 15 13 18 21 14 17 20 16, 19, 22 29 27 36 28 3 30 9 10 31 1 37 2 38 7 Location Part No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-4M27YACV-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-4M27YACV-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag