SERVICE MANUAL
SPLIT TYPE
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E RAS-4M27GAV-E RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E RAS-4M27GACV-E RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E RAS-3M26GAV-E
Revised pages : 3 & 83
R410A
PRINTED IN JAPAN, May, 2006 ToMo
CONTENTS
1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Wiring Connection How to connect the connecting cable
7 Mounting screw Ø4 × 25L
Clip anchor (local parts)
Fig. 10-3-5
CAUTION
Failure to securely install the unit may result in personal injury and/or property damage if the unit falls. · In case of block, brick, concrete or similar type walls, drill 5 mm dia. · Insert clip anchors for the mounting screws.
NOTE : · Install the installation plate using mounting screws between 4 to 6, being sure to secure all four corners.
Wiring the connecting cable can be carried out without removing the front panel. Open the air inlet grille upward and pull it toward you. Remove the terminal cover and cord clamp. Insert the connecting cable (or as according to local regulations/codes) into the pipe hole on the wall. Pull the connecting cable through the cable slot on the rear panel so that it protrudes about 15 cm out of the front. Insert the connecting cable fully into the terminal block and secure it tightly with screws. Tightening torque: 1. 2 N·m (0. 12 kgf·m) 7. Secure the connecting cable with the cord clamp. Attach the terminal cover, rear plate bushing and air inlet grille on the indoor unit.
76
CAUTION
· Be sure to refer to the wiring system diagram labeled inside the front panel. · Check local electrical regulations for any specific wiring instructions or limitations.
Terminal cover
10-3-5. Piping and Drain Hose Installation Piping and drain hose forming
· Since condensation results in machine trouble, make sure to insulate both the connecting pipes separately. (Use polyethylene foam as insulating material. )
Rear right
Cord clamp
Left
Terminal block
Bottom right Right
Earth wire Connecting cable
Fig. Die-cutting front panel slit Cut out the slit on the left or right side of the front panel for the left or right connection and the slit on the bottom left or side of thefront panel for the bottom left or right connection with a pair of nippers. Changing drain hose For left connection, left-bottom connection and rear-left connection's piping, it is necessary to relocate the drain hose and drain cap.
Fig. 10-3-7
How to remove the drain cap
Clip drain cap with needle-nose pliers, and pull out.
Connecting cable
About 15 cm
Fig. 10-3-11
How to remove the drain hose
The drain hose is secured in place by a screw. Remove the screw securing the drain hose, then pull out the drain hose.
10 mm 50 mm
Fig. 10-3-9
NOTE : WIRE TYPE : more than H07 RN-F or 245 IEC 66. 10-3-12
77
Die-cutting Front panel slit
Bottom left
Drain hose
Changing drain hose
Rear left
Piping preparation
Screw
Screw
How to attach the drain cap
1. [. . . ] 43005640 43005641 43005639 43005643 43005635 43005489 43191651 43122065 43042490 43041785 43046442 37546846 43047684 43047683 43047682 43147196 43047401 43047195 43047685 43047686 43047688 43046449 43046448 43063332 43050407 43063317 43049739 43097212 Description Cabinet, Back Ass'y Cabinet, Side Ass'y Cabinet, Front Ass'y Panel, Upper Cabinet, Air, Outlet Guard, Fin Guard, Fan Bell Mouth, Plastic Base Ass'y Compressor, DA220A2F-20L Valve, Packed, 9. 52 Valve, Packed, 12. 7 Socket, 6. 35 Socket, 9. 52 Socket, 12. 7 Bonnet, 1/4 IN Bonnet, 3/8 IN Bonnet, 1/2 IN Nut, Flare, 1/4 IN Nut, Flare, 3/8 IN Nut, Flare, 1/2 IN Valve, P . M. V. , UKV-18D Coil, P . M. V. , UKV-U061E Holder, Sensor, TO Thermostat, Bimetal Holder, Thermostat Cushion, Rubber Nut Location No. 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Part No. 43047669 43120213 4302C069 43058276 43048066 4301V021 43119390 43046445 43046443 43043748 43043747 43032441 43158192 43047674 43047675 43047680 43047681 43019822 43063321 Description Nut, Flange Fan, Propeller, PJ491 Motor, Fan, DC, ICF-140-63-2R Reactor, CH-47-Z-T Accumulator Ass'y Hanger Hanger Valve, 4-way, STF-0213Z Coil, 4-way, VHV Condenser Ass'y (4M27GACV-E) Condenser Ass'y (4M27GAV-E, 3M26GAV-E) Nipple, Drain Reactor, CH-43-Z-T Cap, Charge, Port, 3/8 IN Cap, Charge, Port, 1/2 IN Cap, Valve, Packed, 3/8 IN Cap, Valve, Packed, 1/2 IN Holder, Sensor, Ø4 TGa (Heat Pump Model) Holder, Sensor, Ø4 TGb, TGc, TGd (Heat Pump Model), TD Holder, Sensor, Ø6 TGb, TGc, TGd (Cooling Only Model) Holder, Sensor, Ø6 TE (Heat Pump Model), TS