User manual TOSHIBA RAS-M10UKV-E SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-M10UKV-E. We hope that this TOSHIBA RAS-M10UKV-E user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAS-M10UKV-E.


Mode d'emploi TOSHIBA RAS-M10UKV-E
Download
Manual abstract: user guide TOSHIBA RAS-M10UKV-ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] FILE NO. SVM-03017 SUPPLEMENT SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10UKV-E, RAS-M13UKV-E, RAS-M16UKV-E RAS-4M27YAV-E RAS-M10UKCV-E, RAS-M13UKCV-E, RAS-M16UKCV-E RAS-4M27YACV-E RAS-M10UKV-E, RAS-M13UKV-E, RAS-M16UKV-E RAS-3M26YAV-E R410A June, 2003 CONTENTS 1. SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Check local electrical cords and also any specific wiring instructions or limitations. Terminal cover Screw Cord clamp Teminal block How to install the Drain Hose Firmly insert drain hose connecting part until hitting on a heat insulator. Heat insulator How to fix the Drains Cap Screw Earth wire 4 mm 1) Insert hexagonal wrench (4 mm) in a center head. Connecting cable Screw NOTE · Wire type : More than H07RN-F or 245IEC66 (1. 0 mm2 or more) 80 mm 10mm 10mm 2) Firmly insert drains cap. No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. Application causes deterioration and drain leakage of the plug. Insert a hexagon wrench (4 mm) Earth line Connecting cable 3 abou 2 t 15 cm 1 10mm 50 mm Fig. 9-2-5 CAUTION Firmly insert the drain hose and drain cap; otherwise, water may leak. ­ 68 ­ Die-cutting Front panel slit Fig. 9-2-9 Piping preparation Changing drain hose Rear left In case of right or left piping · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. Slit 9-2-6 Indoor Unit Fixing 1. Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks. Swing the indoor unit to right and left to confirm that it is firmly hooked up on the installation plate. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confirm that it is firmly hooked up on the installation plate. Hook here 1 Fig. 9-2-10 In case of bottom right or bottom left piping · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. 1 Installation plate Slit 2 Hook Press (unhook) Fig. 9-2-14 · For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing its bottom up at the specified parts. Left-hand connection with piping Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall. When bending the connecting pipe, make sure to use a spring bender so as not to crush the pipe. Bend the connection pipe within a radius of 30 mm (Ø6. 35) 40 mm (Ø9. 52). To connect the pipe after installation of the unit (figure) (To the forefront of flare) 270 mm 170 mm Push Push Fig. 9-2-15 Liquid side Gas side 9-2-7 Drainage 1. Run the drain hose sloped downwards. NOTE Outward form of indoor unit 43 mm · Hole should be made at a slight downward slant on the outdoor side. Do not rise the drain hose. Do not form the drain hose into the waved shape. R30 or less (Ø6. 35) R40 or less (Ø9. 52) (Use polisin (polyethylene core or the like for bending pipe. ) ° 80 Use the handle of screwdriver, etc. 50 mm or more Fig. 9-2-12 NOTE If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them. Do not put the drain hose end into water. Do not put the drain hose end in the drainage ditch. Fig. Put water in the drain pan and make sure that the water is drained out of doors. [. . . ] MCC-867 (RAS-M16UKCV-E) ­ 110 ­ 217 216 217 Indoor Unit RAS-M10UKV-E, RAS-M13UKV-E, RAS-M16UKV-E, RAS-M10UKCV-E, RAS-M13UKCV-E, RAS-M16UKCV-E 214 210 211 215 212 219 220 201 205 207 233 222 223 224 221 209 218 208 203 225 204 202 Electric Parts 229 204 234 206 228 226 Assembly 227 Location Part No. 201 202 203 204 205 206 207 208 209 211 212 212 214 215 216 217 218 219 220 221 222 223 224 225 43T00352 43T09316 43T03302 43T80301 43T09309 43T08350 13T70002 43T79301 43T21321 43T47006 43T47305 43T47016 43T11301 43T19302 43T49302 43T49006 43T79302 43T22002 43T39301 43T20302 43T39302 43T21327 43T39303 43T82301 Description Panel Ass'y, Front Inlet Grille Assy Back body Assy Air Filter Horizontal Louver LED Panel Assy Drain Hose Cap Drain Motor Louver Refrigeration Cycle Assy Pipe Delivery Pipe Suction (For M10 and M13) Pipe Suction (For M16) Pipe Shield Holder Sensor Plate of EVA Seal Holder Plate EVA Seal Guide Drain Bearing Base Bearing Fan Cross Flow Band Motor - L Motor Fan Band Motor -R Plate Installation Location Part No. 226 43T69310 Description Remote Controller (For RAS-M10UKCV-E, RAS-M13UKCV-E, and RAS-M16UKCV-E) Remote Controller (For RAS-M10UKV-E, RAS-M13UKV-E, and RAS-M16UKV-E) Holder Remote Controller Owner's Manual Terminal Cover Cord Motor Louver Cord Motor Fan Holder pipe Mark 226 43T69327 227 228 229 231 232 233 234 43T83003 43T85362 43T62302 43T60317 43T60316 43T07303 43T01303 ­ 111 ­ 12. 2. Outdoor Unit RAS-4M27YAV-E/ RAS-4M27YACV-E/ RAS-3M26YAV-E 4 6 39 43 34 32 33 11, 42 35 23 24 25 26 12 15 13 18 21 14 17 20 16, 19, 22 29 27 36 28 3 30 9 10 31 1 37 2 38 7 Location Part No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-M10UKV-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-M10UKV-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag