If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-M10YDCV-E. We hope that this TOSHIBA RAS-M10YDCV-E user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAS-M10YDCV-E.
Manual abstract: user guide TOSHIBA RAS-M10YDCV-ESERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Heat Pump Model
Cooling Only Model
RAS-M10YDV-E RAS-M10YDCV-E RAS-M13YDV-E RAS-M13YDCV-E RAS-M16YDV-E RAS-M16YDCV-E
R410A
PRINTED IN JAPAN, Jul. , 2002 ToMo
CONTENTS
APPLICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PRECAUTIONS FOR SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The copper pipe gauge is useful for adjusting projection margin size.
A
Fig. 9-6-2
CAUTION
IMPORTANT 4 POINTS FOR PIPING WORK 1. Take away dust and moisture from the inside of the connecting pipes. Tight connection (between pipes and unit) 3. Evacuate the air in the connecting pipes using VACUUM PUMP . (connected points)
[Tightening connection]
Align the centers of the connecting pipes and tighten the flare nut as far as possible with your fingers. Then tighten the nut with a spanner and torque wrench as shown in the figure.
CAUTION
· Do not apply excess torque. Otherwise, the nut may crack depending on the conditions. of copper pipe 6. 35 mm (diam. ) 9. 52 mm (diam. ) 12. 7 mm (diam. ) Tightening torque 14 to 18 (1. 4 to 1. 8 kgf·m) 33 to 42 (3. 3 to 4. 2 kgf·m) 50 to 62 (5. 0 to 6. 2 kgf·m)
[Flaring]
Insert a flare nut into the pipe, and flare the pipe. As the flaring sizes of R410A differ from those of refrigerant R22, the flare tools newly manufactured for R410A are recommended. B However, the conventional tools can be used by adjusting projection margin of the copper pipe. 9-6-1
· Projection margin in flaring : B (Unit : mm) Rigid (Clutch type)
Outer diam. of copper pipe 6. 35 9. 52 12. 7 R410A tool used R410A R22 Conventional tool used R410A 1. 0 to 1. 5 1. 0 to 1. 5 1. 0 to 1. 5 R22 0. 5 to 1. 0 0. 5 to 1. 0 0. 5 to 1. 0
0 to 0. 5 (Same as left) 0 to 0. 5 (Same as left) 0 to 0. 5 (Same as left)
· Tightening torque of flare pipe connections Pressure of R410A becomes higher than that of R22. 1. 6 times) Therefore, using a torque wrench, tighten firmly the flare Flare at pipe connecting sections which indoor unit side connect the indoor and outdoor units up to the specified tightening torque. Incorrect connections may cause not only a gas leakage, but also a trouble of the refrigeration cycle. 9-6-3
Half union Flare nut Internally threaded side Use a torque wrench to tighten.
Imperial (Wing nut type)
Outer diam. of copper pipe 6. 35 9. 52 12. 7 R410A 1. 5 to 2. 0 1. 5 to 2. 0 2. 0 to 2. 5 R22 1. 0 to 1. 5 1. 0 to 1. 5 1. 5 to 2. 0
Externally threaded side Use a wrench to secure.
Fig. Evacuating
AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using vacuum pump. Do not use the refrigerant in the outdoor unit. For details, see the manual of vacuum pump.
[Packed valve handling precautions]
· Open the valve stem all the way out ; do not try to open it beyond the stopper. · Securely tighten the valve stem cap in torque as follows:
Gas side (12. 7 mm (diam. )) Gas side (9. 52 mm (diam. )) Liquid side (6. 35 mm (diam. )) Service port 50 to 62 N·m (5. 0 to 6. 2 kgf·m) 33 to 42 N·m (3. 3 to 4. 2 kgf·m) 14 to 18 N·m (1. 4 to 1. 8 kgf·m) 14 to 18 N·m (1. 4 to 1. 8 kgf·m)
[Use a vacuum pump]
Be sure to use a vacuum pump with counter-flow prevention function so that inside oil of the pump does not flow backward into pipes of the air conditioner when the pump stops. Connect the charge hose from the manifold valve to the service port of the gas side packed valve. [. . . ] WARNING · When removing the four fixing screws of the motor cover, the fan and fan motor come down simultaneously. Be sure to deposit the motor cover while holding it by hands. Otherwise, it may be resulted in falling of motor with heavy weight. Remaks
5 4
NOTE : · In reassembling, do not pull each lead wire exceedingly to the fan motor with a little margin. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-M10YDCV-E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.